Trans-catheter closure of atrial septal defect: Balloon sizing or no Balloon sizing - single centre experience

Saurabh Kumar Gupta, S Sivasankaran, S Bijulal, Jagan Mohan Tharakan, S Harikrishnan, Kvk Ajit, Saurabh Kumar Gupta, S Sivasankaran, S Bijulal, Jagan Mohan Tharakan, S Harikrishnan, Kvk Ajit

Abstract

Background: Selecting the device size using a sizing balloon could oversize the ostium secundum atrial septal defect (OSASD) with floppy margins and at times may lead to complications. Identifying the firm margins using trans-esophageal echocardiography (TEE) and selecting appropriate-sized device optimizes ASD device closure. This retrospective study was undertaken to document the safety and feasibility of device closure without balloon sizing the defect.

Methods: Sixty-one consecutive patients who underwent trans-catheter closure of OSASD guided by balloon sizing of the defect and intra procedural fluoroscopy (group I) and 67 consecutive patients in whom TEE was used for defect sizing and as intraprocedural imaging during device deployment (group II) were compared. The procedural success rate, device characteristics, and complications were compared between the two groups.

Results: The procedure was successful in 79.7 % patients. The success rate in group II (60 of 67, 89.6%) was significantly higher than in group I (41 of 61, 67.2 %) (P = 0.002). Mean upsizing of ASD device was significantly lower in group II (P < 0.001). TEE also provided better success rate with smaller device in subjects with large ASD (>25 mm) and in those who were younger than 14 years of age. There were four cases of device embolization (two in each group); of which one died in group II despite successful surgical retrieval.

Conclusion: Balloon sizing may not be essential for successful ASD device closure. TEE-guided sizing of ASD and device deployment provides better success rate with relatively smaller sized device.

Keywords: Atrial septal defect; balloon sizing; trans-catheter closure; trans-esophageal echocardiography.

Conflict of interest statement

Conflict of Interest: None declared

Figures

Figure 1
Figure 1
Procedural success in various subgroups
Figure 2
Figure 2
(a) Device upsizing from defect size measured by TEE or balloon sizing. (b) Device upsizing from defect size measured by TTE

References

    1. Berger F, Ewert P, Bjornstad PG, Dahnert I, Krings G, Brilla- Austenat I, et al. Transcatheter closure as standard treatment for most interatrial defects: Experience in 200 patients treated with the Amplatzer septal occluder. Cardiol Young. 1999;9:468–73.
    1. Chessa M, Carminati M, Butrera G, Bini RM, Drago M, Rosti L, et al. Early and late complications associated with transcatheter occlusion of secundum atrial septal defect. J Am Coll Cardiol. 2002;39:1061–5.
    1. Du ZD, Hijazi ZM, Kleinman CS, Silverman NH. Amplatzer investigators.Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: Results of a multicenter nonrandomized trial. J Am Coll Cardiol. 2002;39:1936–44.
    1. Thanopoulos BD, Laskari CV, Tsaousis GS, Zarayelyan A, Vekiou A, Papadopoulos GS. Closure of atrial septal defects with the Amplatzer occlusion device: Preliminary results. J Am Coll Cardiol. 1998;31:1110–6.
    1. Wang JK, Tsai SK, Wu MH, Lue HC. Short-and intermediate-term results of transcatheter closure of atrial septal defect with the Amplatzer septal occluder. Am Heart J. 2004;148:511–7.
    1. Mathewson JW, Bichell D, Rothman A, Ing FF. Absent posteroinferior and anterosuperior atrial septal defect rims: Factors affecting nonsurgical closure of large secundum defects using the Amplatzer occluder. J Am Soc Echocardiogr. 2004;17:62–9.
    1. Gu X, Han YM, Berry J, Urness M, Amplatz K. A new technique for sizing atrial septal effects. Catheter Cardiovasc Interv. 1995;46:51–7.
    1. Helgason H, Johansson M, Soderberg B, Eriksson P. Sizing of atrial septal defect in adults. Cardiology. 2005;104:1–5.
    1. Du ZD, Cao Q, Rhodes J, Heitschmidt M, Hijazi ZM. Choice of size and results of transcatheter closure of atrial septal defect using the Amplatzer septal occluder. J Interv Cardiol. 2002;15:287–92.
    1. Harper RW, Mottram PM, Mc Gaw DJ. Closure of secundum atrial septal defects with the Amplatzer septal occluder device: Techniques and problems. Catheter Cardiovasc Interv. 2002;57:508–24.
    1. Amin Z, Daufors DA. Balloon sizing is not necessary for closure of secundum atrial septal defects. J Am Coll Cardiol. 2005;45:317.
    1. Zanchetta M. On-line intracardiac echocardiography alone for Amplatzer septal occluder selection and device deployment in adult patients with atrial septal defect. Int J Cardiol. 2004;95:61–8.
    1. Amin Z, Hijazi ZM, Bass JL, Cheatham JP, Hellenbrand WE, Kleinman CS. Erosion of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv. 2004;63:496–502.
    1. Divekar A, Gaamangwe T, Shaikh N, Raabe M, Ducas J. Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder. J Am Coll Cardiol. 2005;45:1213–8.
    1. Levi DS, Moore JW. Embolization and retrieval of the Amplatzer septal occluder. Cateter Cardiovasc Interv. 2004;61:543–71.
    1. Zanchetta M, Onorato E, Rigatelli G, Pedon L, Zennaro M, Carrozza A, et al. Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect. J Am Coll Cardiol. 2003;42:1677–82.
    1. Harikrishnan S, Narayanan NK, Sivasabramonian S. Sizing balloon-induced tear of the atrial septum. J Invasive Cardiol. 2005;17:546–7.
    1. Rao PS, Langhough R. Relationship of echocardiographic, shunt flow, and angiographic size to the stretched diameter of the atrial septal defect. Am Heart J. 1991;122:505–8.
    1. Fisher G, Kramer H, Stieh J, Harding P, Jung O. Transcatheter closure of secundum atrial septal defects with the new self-centering Amplatzer septal occluder. Eur Heart J. 1999;83:933–6.
    1. El-Said HG, Benzold LI, Grifka RG, Pignatelli RH, McMahon CJ, Schuttle DA, et al. Sizing of atrial septal defects to predict successful closure with transcatheter Cardioseal device. Tex Heart Inst J. 2001;28:177–82.
    1. Walsh KP, Maadi IM. The Amplatzer septal occluder. Cardiol Young. 2000;10:493–501.
    1. Carcagni A, Presbitero P. New echocardiographic diameter for Amplatzer sizing in adult patients with secundum atrial septal defect: Preliminary results. Catheter Cardiovasc Interv. 2004;62:409–14.
    1. Godart F, Rey C, Francart C, Jarrar M, Vaksmann G. Two-dimensional echocardiographic and color Doppler measurement of atrial septal defect and comparison with the balloon-stretched diameter. Am J Cardiol. 1993;72:1095–7.
    1. Carlson KM, Justino H, O’Brien RE, Dimas VV, Leonard GT, Jr, Piganatelli RH, et al. Transcatheter atrial septal defect closure: Modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluder. Catheter Cardiovasc Interv. 2005;66:390–6.
    1. Abdel-Massih T, Dulac Y, Taktak A, Aggoun Y, Massabuau P, Elbaz M, et al. Assessment of atrial septal defect size with 3D-transesophageal echocardiography: Comparison with balloon method. Echocardiography. 2005;22:121–7.
    1. Wang JK, Tsai SK, Lin SM, Chiu SN, Lin MT, Wu MH. Transcatheter closure of atrial septal defect without balloon sizing. Catheter Cardiovasc Interv. 2008;71:214–21.

Source: PubMed

3
Sottoscrivi