Factors affecting patients' comfort during fiberoptic bronchoscopy and endobronchial ultrasound

Fatma Yıldırım, Şevket Özkaya, Ahmet Selim Yurdakul, Fatma Yıldırım, Şevket Özkaya, Ahmet Selim Yurdakul

Abstract

Objective: This study investigated the factors that can affect the comfort of patients who underwent diagnostic fiberoptic bronchoscopy (FOB) and diagnostic endobronchial ultrasonography (EBUS) for the first time and the effect of the patients' anxiety level on their comfort during the procedure.

Materials and methods: We recorded the demographics of the patients, the medications they used previously, the anesthesia applied during the procedure, the experience of the operator, the insertion technique of the bronchoscope, the types of the bronchoscopic interventions during the procedure, the duration of the procedure, and the anxiety levels of the patients before the session. Patients' discomfort level before and after the procedure and anxiety levels before the procedure were evaluated using a visual analog scale (VAS), and willingness for repeating FOB and EBUS was assessed using a questionnaire.

Results: We found that longer examination time, higher anxiety level before the procedure, the nasal insertion of bronchoscope, and higher number of interventions are related to the increased discomfort during FOB and EBUS. Patients' willingness for repeating FOB and EBUS increased as the level of discomfort decreased during the procedure.

Conclusion: The patient's anxiety level should be determined using a questionnaire before the FOB and EBUS procedures, and the operator should adjust their procedure according to the patients' anxiety level.

Keywords: endobronchial ultrasound; fiberoptic bronchoscopy; patient anxiety; patient comfort; patient willingness; preprocedure questionnaire.

Conflict of interest statement

Disclosure The authors report no conflicts of interest in this work.

References

    1. Nakaoka Y, Ohata M, Iida M. Anesthesia for diagnostic bronchoscopy. Kikanshigaku. 1990;12:254–261.
    1. Diette GB, White P, Jr, Terry P, Jenckes M, Wise RA, Rubin HR. Quality assessment through patient self-report of symptoms prefiberoptic and postfiberoptic bronchoscopy. Chest. 1998;114(5):1446–1453.
    1. Putinati S, Ballerin L, Corbetta L, Trevisani L, Potena A. Patient satisfaction with conscious sedation for bronchoscopy. Chest. 1999;115(5):1437–1440.
    1. Williams T, Brooks T, Ward C. The role of atropine premedication in fiberoptic bronchoscopy using intravenous midazolam sedation. Chest. 1998;113(5):1394–1398.
    1. Utz JP, Prakash UBS. Indications and contraindications to bronchoscopy. In: Prakash UBS, editor. Bronchoscopy. 1st ed. New York: Raven Press; 1994. pp. 81–89.
    1. Mitsumune T, Senoh E, Adachi M. Prediction of patient discomfort during fiberoptic bronchoscopy. Respirology. 2005;10(1):92–96.
    1. Hirose T, Okuda K, Ishida H, et al. Patient satisfaction with sedation for flexible bronchoscopy. Respirology. 2008;13(5):722–727.
    1. Maltais F, Laberge F, Laviolette M. A randomized, double-blind, placebo-controlled study of lorazepam as premedication for bronchoscopy. Chest. 1996;109(5):1195–1198.
    1. Stolz D, Chhajed PN, Leuppi JD, et al. Cough suppression during flexible bronchoscopy using combined sedation with midazolam and hydrocodone: a randomised, double-blind, placebo-controlled trial. Thorax. 2004;59(9):773–776.
    1. Steinfort DP, Irving LB. Patient satisfaction during endobronchial ultrasound-guided transbronchial needle aspiration performed under conscious sedation. Respir Care. 2010;55(6):702–706.
    1. Lechtzin N, Rubin HR, Jenckes M, et al. Predictors of pain control in patients undergoing flexible bronchoscopy. Am J Respir Crit Care Med. 2000;162(2 pt 1):440–445.
    1. Uzbeck M, Quinn C, Saleem I, Cotter P, Gilmartin JJ, O’Keeffe ST. Randomised controlled trial of the effect of standard and detailed risk disclosure prior to bronchoscopy on peri-procedure anxiety and satisfaction. Thorax. 2009;64(3):224–227.
    1. Choi CM, Yoon HI, Lee SM, et al. Oral insertion of a flexible bronchoscope is associated with less discomfort than nasal insertion for Korean patients. Int J Tuberc Lung Dis. 2005;9(3):344–348.
    1. Poi PJ, Chuah SY, Srinivas P, Liam CK. Common fears of patients undergoing bronchoscopy. Eur Respir J. 1998;11(5):1147–1149.
    1. Lechtzin N, Rubin HR, White P, Jr, et al. Patient satisfaction with bronchoscopy. Am J Respir Crit Care Med. 2002;166(10):1326–1331.

Source: PubMed