Oxygen Reserve Index: Utility as an Early Warning for Desaturation in High-Risk Surgical Patients

Neal W Fleming, Amrik Singh, Leonard Lee, Richard L Applegate 2nd, Neal W Fleming, Amrik Singh, Leonard Lee, Richard L Applegate 2nd

Abstract

Background: Perioperative pulse oximetry hemoglobin saturation (Spo2) measurement is associated with fewer desaturation and hypoxia episodes. However, the sigmoidal nature of oxygen-hemoglobin dissociation limits the accuracy of estimation of the partial pressure of oxygen (Pao2) >80 mm Hg and correspondingly limits the ability to identify when Pao2 >80 mm Hg but falling. We hypothesized that a proxy measurement for oxygen saturation (Oxygen Reserve Index [ORI]) derived from multiwavelength pulse oximetry may allow additional warning time before critical desaturation or hypoxia. To test our hypothesis, we used a Masimo multiwavelength pulse oximeter to compare ORI and Spo2 warning times during apnea in high-risk surgical patients undergoing cardiac surgery.

Methods: This institutional review board-approved prospective study (NCT03021473) enrolled American Society of Anesthesiologists physical status III or IV patients scheduled for elective surgery with planned preinduction arterial catheter placement. In addition to standard monitors, an ORI sensor was placed and patients were monitored with a pulse oximeter displaying the ORI, a nondimensional parameter that ranges from 0 to 1. Patients were then preoxygenated until ORI plateaued. Following induction of anesthesia, mask ventilation with 100% oxygen was performed until neuromuscular blockade was established. Endotracheal intubation was accomplished using videolaryngoscopy to confirm placement. The endotracheal tube was not connected to the breathing circuit, and patients were allowed to be apneic. Ventilation was resumed when Spo2 reached 94%. We defined ORI warning time as the time from when the ORI alarm registered (based on the absolute value and the rate of change) until the Spo2 decreased to 94%. We defined the Spo2 warning time as the time for Spo2 to decrease from 97% to 94%. The added warning time provided by ORI was defined as the difference between ORI warning time and Spo2 warning time.

Results: Forty subjects were enrolled. Complete data for analysis were available from 37 patients. The ORI alarm registered before Spo2 decreasing to 97% in all patients. Median (interquartile range [IQR]) ORI warning time was 80.4 seconds (59.7-105.9 seconds). Median (IQR) Spo2 warning time was 29.0 seconds (20.5-41.0 seconds). The added warning time provided by ORI was 48.4 seconds (95% confidence interval [CI], 40.4-62.0 seconds; P < .0001).

Conclusions: In adult high-risk surgical patients, ORI provided clinically relevant added warning time of impending desaturation compared to Spo2. This additional time may allow modification of airway management, earlier calls for help, or assistance from other providers. The potential patient safety impact of such monitoring requires further study.

Conflict of interest statement

Conflicts of Interest: See Disclosures at the end of the article.

Copyright © 2020 International Anesthesia Research Society.

References

    1. Lam T, Nagappa M, Wong J, Singh M, Wong D, Chung F. Continuous pulse oximetry and capnography monitoring for postoperative respiratory depression and adverse events: a systematic review and meta-analysis. Anesth Analg. 2017;125:2019–2029.
    1. Pedersen T, Nicholson A, Hovhannisyan K, Moller AM, Smith AF, Lewis SR. Pulse oximetry for perioperative monitoring. Cochrane Database Syst Rev. 2014;2014:Cd002013.
    1. Severinghaus JW, Kelleher JF. Recent developments in pulse oximetry. Anesthesiology. 1992;76:1018–1038.
    1. Jubran A. Pulse oximetry. Crit Care. 2015;19:272.
    1. Shah A, Shelley KH. Is pulse oximetry an essential tool or just another distraction? The role of the pulse oximeter in modern anesthesia care. J Clin Monit Comput. 2013;27:235–242.
    1. Beasley R, McNaughton A, Robinson G. New look at the oxyhaemoglobin dissociation curve. Lancet. 2006;367:1124–1126.
    1. Davis DP, Hwang JQ, Dunford JV. Rate of decline in oxygen saturation at various pulse oximetry values with prehospital rapid sequence intubation. Prehosp Emerg Care. 2008;12:46–51.
    1. Simpao AF, Gálvez JA. When seconds count, buy more time: the oxygen reserve index and its promising role in patient monitoring and safety. Anesthesiology. 2016;124:750–751.
    1. Young D, Jewkes C, Spittal M, Blogg C, Weissman J, Gradwell D. Response time of pulse oximeters assessed using acute decompression. Anesth Analg. 1992;74:189–195.
    1. Shamir MY, Avramovich A, Smaka T. The current status of continuous noninvasive measurement of total, carboxy, and methemoglobin concentration. Anesth Analg. 2012;114:972–978.
    1. Applegate RL 2nd, Dorotta IL, Wells B, Juma D, Applegate PM. The relationship between oxygen reserve index and arterial partial pressure of oxygen during surgery. Anesth Analg. 2016;123:626–633.
    1. Scheeren TWL, Belda FJ, Perel A. The oxygen reserve index (ORI): a new tool to monitor oxygen therapy. J Clin Monit Comput. 2018;32:379–389.
    1. Szmuk P, Steiner JW, Olomu PN, Ploski RP, Sessler DI, Ezri T. Oxygen reserve index: a novel noninvasive measure of oxygen reserve–a pilot study. Anesthesiology. 2016;124:779–784.
    1. Vos JJ, Willems CH, van Amsterdam K, et al. Oxygen reserve index: validation of a new variable. Anesth Analg. 2019;129:409–415.
    1. Yoshida K, Isosu T, Noji Y, et al. Usefulness of oxygen reserve index (ORi™), a new parameter of oxygenation reserve potential, for rapid sequence induction of general anesthesia. J Clin Monit Comput. 2018;32:687–691.
    1. Koishi W, Kumagai M, Ogawa S, Hongo S, Suzuki K. Monitoring the Oxygen Reserve Index can contribute to the early detection of deterioration in blood oxygenation during one-lung ventilation. Minerva Anestesiol. 2018;84:1063–1069.
    1. Niwa Y, Shiba J, Fujita H, Oka R, Takeuchi M. Oxygen reserve index (ORi™) contributes to prediction of hypoxemia and patient safety during tracheal stent insertion using rigid bronchoscopy: a case report. J Clin Monit Comput. 2019;33:1011–1014.
    1. Mosier JM, Hypes CD, Sakles JC. Understanding preoxygenation and apneic oxygenation during intubation in the critically ill. Intensive Care Med. 2017;43:226–228.
    1. Benumof JL. Preoxygenation: best method for both efficacy and efficiency. Anesthesiology. 1999;91:603–605.
    1. Nimmagadda U, Salem MR, Crystal GJ. Preoxygenation: physiologic basis, benefits, and potential risks. Anesth Analg. 2017;124:507–517.
    1. Ray S, Kulkarni KS, Dave NM, Chincholi I. The utility of the oxygen reserve index™ in a neonate undergoing re-exploration of a tracheoesophageal fistula. Indian J Anaesth. 2018;62:233–234.
    1. Wilson IH. Hypoxia. Update in anaesthesia. J WFSA. 2009;25:21–25.

Source: PubMed

3
Sottoscrivi