A multicenter, randomized controlled trial of immediate total-body CT scanning in trauma patients (REACT-2)

Joanne C Sierink, Teun Peter Saltzherr, Ludo F M Beenen, Jan S K Luitse, Markus W Hollmann, Johannes B Reitsma, Michael J R Edwards, Joachim Hohmann, Benn J A Beuker, Peter Patka, James W Suliburk, Marcel G W Dijkgraaf, J Carel Goslings, REACT-2 study group, Joanne C Sierink, Teun Peter Saltzherr, Ludo F M Beenen, Jan S K Luitse, Markus W Hollmann, Johannes B Reitsma, Michael J R Edwards, Joachim Hohmann, Benn J A Beuker, Peter Patka, James W Suliburk, Marcel G W Dijkgraaf, J Carel Goslings, REACT-2 study group

Abstract

Background: Computed tomography (CT) scanning has become essential in the early diagnostic phase of trauma care because of its high diagnostic accuracy. The introduction of multi-slice CT scanners and infrastructural improvements made total-body CT scanning technically feasible and its usage is currently becoming common practice in several trauma centers. However, literature provides limited evidence whether immediate total-body CT leads to better clinical outcome then conventional radiographic imaging supplemented with selective CT scanning in trauma patients. The aim of the REACT-2 trial is to determine the value of immediate total-body CT scanning in trauma patients.

Methods/design: The REACT-2 trial is an international, multicenter randomized clinical trial. All participating trauma centers have a multi-slice CT scanner located in the trauma room or at the Emergency Department (ED). All adult, non-pregnant, severely injured trauma patients according to predefined criteria will be included. Patients in whom direct scanning will hamper necessary cardiopulmonary resuscitation or who require an immediate operation because of imminent death (both as judged by the trauma team leader) are excluded. Randomization will be computer assisted. The intervention group will receive a contrast-enhanced total-body CT scan (head to pelvis) during the primary survey. The control group will be evaluated according to local conventional trauma imaging protocols (based on ATLS guidelines) supplemented with selective CT scanning. Primary outcome will be in-hospital mortality. Secondary outcomes are differences in mortality and morbidity during the first year post trauma, several trauma work-up time intervals, radiation exposure, general health and quality of life at 6 and 12 months post trauma and cost-effectiveness.

Discussion: The REACT-2 trial is a multicenter randomized clinical trial that will provide evidence on the value of immediate total-body CT scanning during the primary survey of severely injured trauma patients. If immediate total-body CT scanning is found to be the best imaging strategy in severely injured trauma patients it could replace conventional imaging supplemented with CT in this specific group.

Trial registration: ClinicalTrials.gov: (NCT01523626).

Figures

Figure 1
Figure 1
Study flow chart REACT-2 trial.

References

    1. World Health Organization. The global burden of disease: 2004 update. 2008. 6-12-2010.
    1. Sethi D, Racioppi F, Baumgarten I, Bertollini R. Reducing inequalities from injuries in Europe. Lancet. 2006;368:2243–2250. doi: 10.1016/S0140-6736(06)68895-8.
    1. American College of Surgeons Committee on Trauma. ATLS advanced trauma life support program for doctors. Student Course Manual. 8. Chigago, IL; 2008.
    1. Leidner B, Beckman MO. Standardized whole-body computed tomography as a screening tool in blunt multitrauma patients. Emerg Radiol. 2001;8:20–28. doi: 10.1007/PL00011863.
    1. Sampson MA, Colquhoun KB, Hennessy NL. Computed tomography whole body imaging in multi-trauma: 7years experience. Clin Radiol. 2006;61:365–369. doi: 10.1016/j.crad.2005.12.009.
    1. Linsenmaier U, Krotz M, Hauser H, Rock C, Rieger J, Bohndorf K. et al.Whole-body computed tomography in polytrauma: techniques and management. Eur Radiol. 2002;12:1728–1740. doi: 10.1007/s00330-001-1225-x.
    1. Smith CM, Woolrich-Burt L, Wellings R, Costa ML. Major trauma CT scanning: the experience of a regional trauma centre in the UK. Emerg Med J. 2011;28:378–382. doi: 10.1136/emj.2009.076414.
    1. Rieger M, Czermak B, El AR, Sumann G, Jaschke W, Freund M. Initial clinical experience with a 64-MDCT whole-body scanner in an emergency department: better time management and diagnostic quality? J Trauma. 2009;66:648–657. doi: 10.1097/TA.0b013e31816275f3.
    1. Salim A, Sangthong B, Martin M, Brown C, Plurad D, Demetriades D. Whole body imaging in blunt multisystem trauma patients without obvious signs of injury: results of a prospective study. Arch Surg. 2006;141:468–473. doi: 10.1001/archsurg.141.5.468.
    1. Albrecht T, Von SJ, Stahel PF, Ertel W, Wolf KJ. [The role of whole body spiral CT in the primary work-up of polytrauma patients--comparison with conventional radiography and abdominal sonography] Rofo. 2004;176:1142–1150. doi: 10.1055/s-2004-813259.
    1. Saltzherr TP, Bakker FC, Beenen LFM, Dijkgraaf MGW, Reitsma JB, Goslings JC. et al.Randomized clinical trial comparing the effect of computed tomography in the trauma room versus the radiology department on injury outcomes. Br J Surg. 2012;99:105–113. doi: 10.1002/bjs.7705.
    1. Fung Kon Jin PH, Goslings JC, Ponsen KJ, van KC, Hoogerwerf N, Luitse JS. Assessment of a new trauma workflow concept implementing a sliding CT scanner in the trauma room: the effect on workup times. J Trauma. 2008;64:1320–1326. doi: 10.1097/TA.0b013e318059b9ae.
    1. Ptak T, Rhea JT, Novelline RA. Experience with a continuous, single-pass whole-body multidetector CT protocol for trauma: The three-minute multiple trauma CT scan. Emerg Radiol. 2001;8:250–256. doi: 10.1007/PL00011915.
    1. Philipp MO, Kubin K, Hormann M, Metz VM. Radiological emergency room management with emphasis on multidetector-row CT. Eur J Radiol. 2003;48:2–4. doi: 10.1016/S0720-048X(03)00206-7.
    1. Kanz KG, Korner M, Linsenmaier U, Kay MV, Huber-Wagner SM, Kreimeier U. et al.Priority-oriented shock trauma room management with the integration of multiple-view spiral computed tomography. Unfallchirurg. 2004;107:937–944. doi: 10.1007/s00113-004-0845-4.
    1. Prokop A, Hotte H, Kruger K, Rehm KE, Isenberg J, Schiffer G. Multislice CT in diagnostic work-up of polytrauma. Unfallchirurg. 2006;109:545–550. doi: 10.1007/s00113-006-1086-5.
    1. Gralla J, Spycher F, Pignolet C, Ozdoba C, Vock P, Hoppe H. Evaluation of a 16-MDCT scanner in an emergency department: initial clinical experience and workflow analysis. AJR Am J Roentgenol. 2005;185:232–238.
    1. Fung Kon Jin PH, van Geene AR, Linnau KF, Jurkovich GJ, Ponsen KJ, Goslings JC. Time factors associated with CT scan usage in trauma patients. Eur J Radiology. 2009;72(1):134–138. doi: 10.1016/j.ejrad.2008.06.022.
    1. Leidner B, Adiels M, Aspelin P, Gullstrand P, Wallen S. Standardized CT examination of the multitraumatized patient. Eur Radiol. 1998;8:1630–1638. doi: 10.1007/s003300050601.
    1. Fanucci E, Fiaschetti V, Rotili A, Floris R, Simonetti G. Whole body 16-row multislice CT in emergency room: effects of different protocols on scanning time, image quality and radiation exposure. Emerg Radiol. 2007;13:251–257. doi: 10.1007/s10140-006-0554-0.
    1. Nguyen D, Platon A, Shanmuganathan K, Mirvis SE, Becker CD, Poletti PA. Evaluation of a single-pass continuous whole-body 16-MDCT protocol for patients with polytrauma. AJR Am J Roentgenol. 2009;192:3–10. doi: 10.2214/AJR.07.3702.
    1. Weninger P, Mauritz W, Fridrich P, Spitaler R, Figl M, Kern B. et al.Emergency room management of patients with blunt major trauma: evaluation of the multislice computed tomography protocol exemplified by an urban trauma center. J Trauma. 2007;62:584–591. doi: 10.1097/.
    1. Wurmb T, Balling H, Fruhwald P, Keil T, Kredel M, Meffert R. et al.Polytrauma management in a period of change. Unfallchirurg. 2009;112:390–399. doi: 10.1007/s00113-008-1528-3.
    1. Wurmb TE, Quaisser C, Balling H, Kredel M, Muellenbach R, Kenn W. et al.Whole-body multislice computed tomography (MSCT) improves trauma care in patients requiring surgery after multiple trauma. Emerg Med J. 2011;28:300–304. doi: 10.1136/emj.2009.082164.
    1. Huber-Wagner S, Lefering R, Qvick LM, Korner M, Kay MV, Pfeifer KJ. et al.Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study. Lancet. 2009;373:1455–1461. doi: 10.1016/S0140-6736(09)60232-4.
    1. Sierink JC, Saltzherr TP, Reitsma JB, Van Delden OM, Luitse JSK, Goslings JC. Systematic review and meta-analysis of immediate total-body computed tomography compared with selective radiological imaging of injured patients. Br J Surg. 2012;99:52–58. doi: 10.1002/bjs.7760.
    1. Ptak T, Rhea JT, Novelline RA. Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: initial experience. Radiology. 2003;229:902–905. doi: 10.1148/radiol.2293021651.
    1. Ruchholtz S, Waydhas C, Schroeder T, Piepenbrink K, Kuhl H, Nast-Kolb D. The value of computed tomography in the early treatment of seriously injured patients. Chirurg. 2002;73:1005–1012. doi: 10.1007/s00104-002-0429-1.
    1. Hilbert P, Zur NK, Hofmann GO, Hoeller I, Koch R, Stuttmann R. New aspects in the emergency room management of critically injured patients: a multi-slice CT-oriented care algorithm. Injury. 2007;38:552–558. doi: 10.1016/j.injury.2006.12.023.
    1. WMA Declaration of Helsinki - Ethical Principles for Medical Research Involving Human Subjects. 2011.
    1. Brenner DJ, Elliston CD. Estimated radiation risks potentially associated with full-body CT screening. Radiology. 2004;232:735–738. doi: 10.1148/radiol.2323031095.
    1. Tien HC, Tremblay LN, Rizoli SB, Gelberg J, Spencer F, Caldwell C. et al.Radiation exposure from diagnostic imaging in severely injured trauma patients. J Trauma. 2007;62:151–156. doi: 10.1097/TA.0b013e31802d9700.
    1. Kim PK, Gracias VH, Maidment AD, O'Shea M, Reilly PM, Schwab CW. Cumulative radiation dose caused by radiologic studies in critically ill trauma patients. J Trauma. 2004;57:510–514. doi: 10.1097/01.TA.0000141028.97753.67.

Source: PubMed

3
Sottoscrivi