Effects of practitioner's experience on the clinical performance of ultrasound-guided central venous catheterization: a randomized trial

Hyun-Kyu Yoon, Min Hur, Hyeyeon Cho, Young Hyun Jeong, Ho-Jin Lee, Seong-Mi Yang, Won Ho Kim, Hyun-Kyu Yoon, Min Hur, Hyeyeon Cho, Young Hyun Jeong, Ho-Jin Lee, Seong-Mi Yang, Won Ho Kim

Abstract

We investigated whether two needle insertion techniques for ultrasound-guided internal jugular vein (IJV) catheterization differ in the number of needling attempts and complication rate between inexperienced and experienced practitioners. A total of 308 patients requiring IJV catheterization were randomly assigned into one of four groups: IJV catheterization performed by inexperienced practitioners using either Seldinger (IE-S; n = 78) or modified Seldinger technique (IE-MS; n = 76) or IJV catheterization performed by experienced practitioners using either Seldinger (E-S; n = 78) or modified Seldinger technique (E-MS; n = 76). All catheterizations were performed under the real-time ultrasound guidance. The number of needling attempts was not significantly different between the two techniques within each experience group (between IE-S vs. IE-MS P = 0.550, between E-S and E-MS P = 0.834). Time to successful catheterization was significantly shorter in the E-S group compared to E-MS group (P < 0.001) while no significant difference between IE-S and IE-MS groups (P = 0.226). Complication rate was not significantly different between the two techniques within each experience group. Practitioner's experience did not significantly affect the clinical performance of needle insertion techniques during ultrasound-guided IJV catheterization except the time to successful catheterization. Regarding the number of needling attempts and complication rate, both techniques could be equally recommended regardless of practitioner's experience.Trial registration: clinicaltrials.gov (https://ichgcp.net/clinical-trials-registry/NCT03077802).

Conflict of interest statement

The authors declare no competing interests

Figures

Figure 1
Figure 1
CONSORT flow diagram of the study.

References

    1. Ruesch S, Walder B, Tramer MR. Complications of central venous catheters: internal jugular versus subclavian access—a systematic review. Crit. Care Med. 2002;30:454–460. doi: 10.1097/00003246-200202000-00031.
    1. McGee DC, Gould MK. Preventing complications of central venous catheterization. N. Engl. J. Med. 2003;348:1123–1133. doi: 10.1056/NEJMra011883.
    1. Bannon MP, Heller SF, Rivera M. Anatomic considerations for central venous cannulation. Risk Manag. Healthc. Policy. 2011;4:27–39. doi: 10.2147/RMHP.S10383.
    1. Eisen LA, et al. Mechanical complications of central venous catheters. J. Intensive Care Med. 2006;21:40–46. doi: 10.1177/0885066605280884.
    1. Karakitsos D, et al. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Crit. Care. 2006;10:R162. doi: 10.1186/cc5101.
    1. Denys, B. G., Uretsky, B. F. & Reddy, P. S. Ultrasound-assisted cannulation of the internal jugular vein. A prospective comparison to the external landmark-guided technique. Circulation87, 1557–1562 (1993).
    1. Schummer, W., Schummer, C., Rose, N., Niesen, W. D. & Sakka, S. G. Mechanical complications and malpositions of central venous cannulations by experienced operators. A prospective study of 1794 catheterizations in critically ill patients. Intensive Care Med.33, 1055–1059 (2007).
    1. Brass, P., Hellmich, M., Kolodziej, L., Schick, G. & Smith, A. F. Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization. Cochrane Database Syst. Rev.1, Cd006962 (2015).
    1. Frankel HL, et al. Guidelines for the appropriate use of bedside general and cardiac ultrasonography in the evaluation of critically Ill patients-part I: general ultrasonography. Crit. Care Med. 2015;43:2479–2502. doi: 10.1097/CCM.0000000000001216.
    1. American Society of Anesthesiologists Task Force on Central Venous, A. et al. Practice guidelines for central venous access: a report by the American Society of Anesthesiologists Task Force on Central Venous Access. Anesthesiology116, 539–573 (2012).
    1. Lee YH, et al. Comparison of needle insertion and guidewire placement techniques during internal jugular vein catheterization: the thin-wall introducer needle technique versus the cannula-over-needle technique. Crit. Care Med. 2015;43:2112–2116. doi: 10.1097/CCM.0000000000001167.
    1. Kim E, et al. A prospective randomised trial comparing insertion success rate and incidence of catheterisation-related complications for subclavian venous catheterisation using a thin-walled introducer needle or a catheter-over-needle technique. Anaesthesia. 2016;71:1030–1036. doi: 10.1111/anae.13543.
    1. Song IK, et al. Comparison of central venous catheterization techniques in pediatric patients: needle vs angiocath. Paediatr. Anaesth. 2015;25:1120–1126. doi: 10.1111/pan.12726.
    1. Song IK, et al. Seldinger vs modified Seldinger techniques for ultrasound-guided central venous catheterisation in neonates: a randomised controlled trial. Br. J. Anaesth. 2018;121:1332–1337. doi: 10.1016/j.bja.2018.08.008.
    1. English IC, Frew RM, Pigott JF, Zaki M. Percutaneous cannulation of the internal jugular vein. Thorax. 1969;24:496–497. doi: 10.1136/thx.24.4.496.
    1. Sznajder, J. I., Zveibil, F. R., Bitterman, H., Weiner, P. & Bursztein, S. Central vein catheterization. Failure and complication rates by three percutaneous approaches. Arch. Intern. Med.146, 259–261 (1986).
    1. Practice Guidelines for Central Venous Access 2020. Anesthesiology132, 8–43 (2020).
    1. Nguyen BV, et al. Determination of the learning curve for ultrasound-guided jugular central venous catheter placement. Intensive Care Med. 2014;40:66–73. doi: 10.1007/s00134-013-3069-7.
    1. Lennon M, Zaw NN, Popping DM, Wenk M. Procedural complications of central venous catheter insertion. Minerva Anestesiol. 2012;78:1234–1240.
    1. Hayashi Y, et al. Internal jugular vein catheterization in infants undergoing cardiovascular surgery: an analysis of the factors influencing successful catheterization. Anesth. Analg. 1992;74:688–693. doi: 10.1213/00000539-199205000-00012.
    1. Jobes DR. The element of experience in internal jugular vein catheterization. Anesth. Analg. 1992;75:643. doi: 10.1213/00000539-199210000-00048.
    1. Troianos CA, et al. Special articles: guidelines for performing ultrasound guided vascular cannulation: recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. Anesth. Analg. 2012;114:46–72. doi: 10.1213/ANE.0b013e3182407cd8.
    1. Chittoodan S, Breen D, O'Donnell BD, Iohom G. Long versus short axis ultrasound guided approach for internal jugular vein cannulation: a prospective randomised controlled trial. Med. Ultrason. 2011;13:21–25.
    1. Stone MB, Moon C, Sutijono D, Blaivas M. Needle tip visualization during ultrasound-guided vascular access: short-axis vs long-axis approach. Am. J. Emerg. Med. 2010;28:343–347. doi: 10.1016/j.ajem.2008.11.022.
    1. Zhang J, et al. Comparison of short and long axis ultrasound-guided approaches to internal jugular vein puncture: a meta-analysis. J. Int. Med. Res. 2019;47:4069–4082. doi: 10.1177/0300060519867806.