Monitoring of Non-invasive Ventilation During Sleep in ALS
Non-invasive ventilation (NIV) has already shown to improve survival and quality of life in patients with amyotrophic lateral sclerosis (ALS). Quality of sleep seems already to be impaired in patients with preserved diaphragmatic dysfunction. Until now, only few research has been performed on the quality of sleep in patients with ALS when using NIV, and these data are mainly based on patient reported outcomes.Further on, only very little research has been done on patient-ventilator interaction.
Our study would like to perform research on quality of sleep before and after NIV use by using full polysomnography with incorporation of transcutaneous carbon dioxide measurement and built-in ventilator software.
調査の概要
状態
条件
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
-
Leuven、ベルギー、3000
- UZ Leuven
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
Patients with ALS (according to El Escorial criteria) who are planned to start to use NIV, objectivated by a decreased inspiratory muscle force with a restrictive pulmonary function and
- symptoms of nocturnal alveolar hypoventilation or
- increased daytime arterial carbon dioxide partial pressure (PCO2)(> 45 mmHg) or
- a ≥ 10 mmHg increase in transcutaneous PCO2 during sleep in comparison to a normal awake supine value
Exclusion Criteria:
- Patients < 18 years
- Patients not willing to start NIV
研究計画
研究はどのように設計されていますか?
デザインの詳細
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in transcutaneous carbon dioxide and respiratory events
時間枠:At day 2, 3 and 4 and at 1, 3, 6, 9 and 12 months
|
Search for an optimal titration protocol.
Aim is to reduce transcutaneous carbon dioxide (CO2) below 55 mmHg and to reduce central and obstructive respiratory events to a minimum.
This will be assessed by performance of a nocturnal measurement of transcutaneous CO2 and full polysomnography at eacht time point.
|
At day 2, 3 and 4 and at 1, 3, 6, 9 and 12 months
|
|
Change in patient-ventilator asynchronies
時間枠:Day 4 and at 1,3,6,9 and 12 months
|
The following asynchronies will be evaluated: auto-triggering, double triggering, ineffective effort, prolonged insufflation.
The impact of leaks will also be evaluated.Data will be reported as events/hour of sleep.
This will be assessed by full polysomnography at each time point.
|
Day 4 and at 1,3,6,9 and 12 months
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
Impact of NIV on sympatho-vagal balance
時間枠:Day 1 and at 1,3,6,9 and 12 months
|
Day 1 and at 1,3,6,9 and 12 months
|
|
changes in quality of life by patient reported outcomes
時間枠:Day 1 and at 1,3,6,9 and 12 months
|
Day 1 and at 1,3,6,9 and 12 months
|
協力者と研究者
捜査官
- 主任研究者:Dries Testelmans, MD,PhD、UZ Leuven
- スタディディレクター:Bertien Buyse, MD, PhD、UZ Leuven
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。