Influence of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew Implants
2018年1月17日 更新者:Guido Artemio Marañón Vásquez、University of Sao Paulo
Effect of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew Implants With Mediate and Immediate Force Application
The purpose of this study is to evaluate the effect of Low level laser therapy on stability and displacement of orthodontic miniscrew implants using two different force application protocols.
調査の概要
状態
完了
条件
詳細な説明
The aim of this study is to evaluate the effect of Low level laser therapy (LLLT) on stability and displacement of orthodontic miniscrew implants with mediate and immediate force application.
They will be assessed 48 miniscrew implants placed in patients in orthodontic treatment at the postgraduate clinical in Orthodontics, at School of Dentistry of Ribeirão Preto, University of São Paulo.
They will be randomly divided into 4 groups: 1- LLLT and immediate force application; 2- LLLT and force application 4 weeks after implantation; 3- immediate force application without LLLT and 4- force application 4 weeks after implantation without LLLT.
Orthodontic force of 150 gF will be applied for 3 months.
A low power laser device Therapy XT with a wavelength of 660 nm and output of 100 mW immediately after implantation (energy density: 4J/cm2), and 808 nm with 100 mW (energy density: 8J/cm2), every 48 hours for two weeks in the following applications will be used.
The stability will be assessed using Resonance Frequency Analysis (RFA) at three times: the implantation day (T1), one month (T2) and after 3 months of force application (T3).
Stability measures will be evaluated in Implant Stability Quotient (ISQ).
To assess the amount of miniscrew implant displacement, it will be used Cone Beam Computed Tomography (CBCT) at the beginning (CT1) and final of the application of orthodontic force (CT2).
Three-dimensional models will be created in specific programs and superimpositions of CT1 and CT2 will be used to measure the distance in millimeters between inicial and final position.
The evaluation will be carried out in three points: head of miniscrew implant (point C), thread (point R) and apex of miniscrew implant (point A).
The results will be statistically analyzed according to nature of the data and the significance level to be adopted will be 5%.
研究の種類
介入
入学 (実際)
29
段階
- 適用できない
参加基準
研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。
適格基準
就学可能な年齢
11年歳以上 (子、大人、高齢者)
健康ボランティアの受け入れ
はい
受講資格のある性別
全て
説明
Inclusion Criteria:
- Patient with permanent teeth.
- Use of miniscrews in orthodontic planning.
- Miniscrews placed in the labial upper and lower posterior regions.
- Patient who agree to participate (Informed consent)
Exclusion Criteria:
- Patient with systemic disease.
- Patient with periodontal disease and/or inadequate oral hygiene.
- Use of drugs chronically.
- Patients that consume alcohol or tobacco.
- Use of fixed palatal or lingual orthodontic devices.
研究計画
このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:支持療法
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:LLLT + immediate force
Use of Low-level laser therapy and not mediate orthodontic force application (150 gF the day of the implantation).
|
|
|
実験的:LLLT + mediate force
Use of Low-level laser therapy and mediate orthodontic force application (150 gF 4 weeks after the day of the implantation).
|
Mediate force application protocol: orthodontic force application (150 gF) 4 weeks after the day of the implantation.
|
|
介入なし:Immediate force application
Not mediate orthodontic force application (150 gF the day of the implantation), without use of Low-level laser therapy.
|
|
|
実験的:Mediate force application
Mediate orthodontic force application (150 gF 4 weeks after the day of the implantation), without use of Low-level laser therapy.
|
Mediate force application protocol: orthodontic force application (150 gF) 4 weeks after the day of the implantation.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change from baseline miniscrew implant stability at 1 and 3 months of force application.
時間枠:T1: Implantation day; T2: after 1 month; and, T3: after 3 months of force application.
|
It will be used a Resonance frequency analysis (RFA) equipment.
Stability measures will be evaluated using a unique unit of measure: Implant stability quotient (ISQ).
All groups will be evaluated the day of the implantation (T1) and after 1 month (T2).The last stability measure (T3) will be done 3 months after the implantation day in the groups without mediate force application, and 4 months after the implantation day in the groups with mediate force application.
|
T1: Implantation day; T2: after 1 month; and, T3: after 3 months of force application.
|
|
Change from baseline miniscrew implant position at 3 months of force application.
時間枠:CT1: Implantation day; and, CT2: 3 months of orthodontic force application.
|
It will be used Cone Beam Computed tomography (CBCT).
Three-dimensional models will be created in specific programs and superimpositions of CT1 and CT2 will be used to measure the distance in millimeters between initial and final position.
|
CT1: Implantation day; and, CT2: 3 months of orthodontic force application.
|
協力者と研究者
ここでは、この調査に関係する人々や組織を見つけることができます。
スポンサー
捜査官
- 主任研究者:Guido A Marañón Vásquez, DDS、University of Sao Paulo
研究記録日
これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。
主要日程の研究
研究開始
2016年3月1日
一次修了 (実際)
2017年2月1日
研究の完了 (実際)
2017年8月1日
試験登録日
最初に提出
2016年8月23日
QC基準を満たした最初の提出物
2016年8月31日
最初の投稿 (見積もり)
2016年9月7日
学習記録の更新
投稿された最後の更新 (実際)
2018年1月18日
QC基準を満たした最後の更新が送信されました
2018年1月17日
最終確認日
2018年1月1日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
- USaoPaulo-1
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。