Influence of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew Implants

17. ledna 2018 aktualizováno: Guido Artemio Marañón Vásquez, University of Sao Paulo

Effect of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew Implants With Mediate and Immediate Force Application

The purpose of this study is to evaluate the effect of Low level laser therapy on stability and displacement of orthodontic miniscrew implants using two different force application protocols.

Přehled studie

Detailní popis

The aim of this study is to evaluate the effect of Low level laser therapy (LLLT) on stability and displacement of orthodontic miniscrew implants with mediate and immediate force application. They will be assessed 48 miniscrew implants placed in patients in orthodontic treatment at the postgraduate clinical in Orthodontics, at School of Dentistry of Ribeirão Preto, University of São Paulo. They will be randomly divided into 4 groups: 1- LLLT and immediate force application; 2- LLLT and force application 4 weeks after implantation; 3- immediate force application without LLLT and 4- force application 4 weeks after implantation without LLLT. Orthodontic force of 150 gF will be applied for 3 months. A low power laser device Therapy XT with a wavelength of 660 nm and output of 100 mW immediately after implantation (energy density: 4J/cm2), and 808 nm with 100 mW (energy density: 8J/cm2), every 48 hours for two weeks in the following applications will be used. The stability will be assessed using Resonance Frequency Analysis (RFA) at three times: the implantation day (T1), one month (T2) and after 3 months of force application (T3). Stability measures will be evaluated in Implant Stability Quotient (ISQ). To assess the amount of miniscrew implant displacement, it will be used Cone Beam Computed Tomography (CBCT) at the beginning (CT1) and final of the application of orthodontic force (CT2). Three-dimensional models will be created in specific programs and superimpositions of CT1 and CT2 will be used to measure the distance in millimeters between inicial and final position. The evaluation will be carried out in three points: head of miniscrew implant (point C), thread (point R) and apex of miniscrew implant (point A). The results will be statistically analyzed according to nature of the data and the significance level to be adopted will be 5%.

Typ studie

Intervenční

Zápis (Aktuální)

29

Fáze

  • Nelze použít

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

11 let a starší (Dítě, Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ano

Pohlaví způsobilá ke studiu

Všechno

Popis

Inclusion Criteria:

  • Patient with permanent teeth.
  • Use of miniscrews in orthodontic planning.
  • Miniscrews placed in the labial upper and lower posterior regions.
  • Patient who agree to participate (Informed consent)

Exclusion Criteria:

  • Patient with systemic disease.
  • Patient with periodontal disease and/or inadequate oral hygiene.
  • Use of drugs chronically.
  • Patients that consume alcohol or tobacco.
  • Use of fixed palatal or lingual orthodontic devices.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Podpůrná péče
  • Přidělení: Randomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Singl

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: LLLT + immediate force
Use of Low-level laser therapy and not mediate orthodontic force application (150 gF the day of the implantation).
  1. Immediate post-operative period (implantation day) Red emission (660 nm) Energy density: 4 J/cm2 Power: 0.1W Irradiation area: 0,5 cm2 One application, 10 seconds of non-contact irradiation (01 point at the area surrounding the miniscrew) at a distance of 15,5 mm.
  2. Mediate post-operative period (after implantation day) Infrared emission (808 nm) Energy density: 8 J/cm2 Power: 0.1W Irradiation area: 0,5 cm2 6 applications every 48 hours after the day of implantation, 20 seconds of non-contact irradiation (01 point on the area surrounding the miniscrew) at a distance of 15,5 mm.
Experimentální: LLLT + mediate force
Use of Low-level laser therapy and mediate orthodontic force application (150 gF 4 weeks after the day of the implantation).
  1. Immediate post-operative period (implantation day) Red emission (660 nm) Energy density: 4 J/cm2 Power: 0.1W Irradiation area: 0,5 cm2 One application, 10 seconds of non-contact irradiation (01 point at the area surrounding the miniscrew) at a distance of 15,5 mm.
  2. Mediate post-operative period (after implantation day) Infrared emission (808 nm) Energy density: 8 J/cm2 Power: 0.1W Irradiation area: 0,5 cm2 6 applications every 48 hours after the day of implantation, 20 seconds of non-contact irradiation (01 point on the area surrounding the miniscrew) at a distance of 15,5 mm.
Mediate force application protocol: orthodontic force application (150 gF) 4 weeks after the day of the implantation.
Žádný zásah: Immediate force application
Not mediate orthodontic force application (150 gF the day of the implantation), without use of Low-level laser therapy.
Experimentální: Mediate force application
Mediate orthodontic force application (150 gF 4 weeks after the day of the implantation), without use of Low-level laser therapy.
Mediate force application protocol: orthodontic force application (150 gF) 4 weeks after the day of the implantation.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Change from baseline miniscrew implant stability at 1 and 3 months of force application.
Časové okno: T1: Implantation day; T2: after 1 month; and, T3: after 3 months of force application.
It will be used a Resonance frequency analysis (RFA) equipment. Stability measures will be evaluated using a unique unit of measure: Implant stability quotient (ISQ). All groups will be evaluated the day of the implantation (T1) and after 1 month (T2).The last stability measure (T3) will be done 3 months after the implantation day in the groups without mediate force application, and 4 months after the implantation day in the groups with mediate force application.
T1: Implantation day; T2: after 1 month; and, T3: after 3 months of force application.
Change from baseline miniscrew implant position at 3 months of force application.
Časové okno: CT1: Implantation day; and, CT2: 3 months of orthodontic force application.
It will be used Cone Beam Computed tomography (CBCT). Three-dimensional models will be created in specific programs and superimpositions of CT1 and CT2 will be used to measure the distance in millimeters between initial and final position.
CT1: Implantation day; and, CT2: 3 months of orthodontic force application.

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: Guido A Marañón Vásquez, DDS, University of Sao Paulo

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia

1. března 2016

Primární dokončení (Aktuální)

1. února 2017

Dokončení studie (Aktuální)

1. srpna 2017

Termíny zápisu do studia

První předloženo

23. srpna 2016

První předloženo, které splnilo kritéria kontroly kvality

31. srpna 2016

První zveřejněno (Odhad)

7. září 2016

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

18. ledna 2018

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

17. ledna 2018

Naposledy ověřeno

1. ledna 2018

Více informací

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit