- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT02891499
Influence of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew Implants
17 января 2018 г. обновлено: Guido Artemio Marañón Vásquez, University of Sao Paulo
Effect of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew Implants With Mediate and Immediate Force Application
The purpose of this study is to evaluate the effect of Low level laser therapy on stability and displacement of orthodontic miniscrew implants using two different force application protocols.
Обзор исследования
Статус
Завершенный
Условия
Вмешательство/лечение
Подробное описание
The aim of this study is to evaluate the effect of Low level laser therapy (LLLT) on stability and displacement of orthodontic miniscrew implants with mediate and immediate force application.
They will be assessed 48 miniscrew implants placed in patients in orthodontic treatment at the postgraduate clinical in Orthodontics, at School of Dentistry of Ribeirão Preto, University of São Paulo.
They will be randomly divided into 4 groups: 1- LLLT and immediate force application; 2- LLLT and force application 4 weeks after implantation; 3- immediate force application without LLLT and 4- force application 4 weeks after implantation without LLLT.
Orthodontic force of 150 gF will be applied for 3 months.
A low power laser device Therapy XT with a wavelength of 660 nm and output of 100 mW immediately after implantation (energy density: 4J/cm2), and 808 nm with 100 mW (energy density: 8J/cm2), every 48 hours for two weeks in the following applications will be used.
The stability will be assessed using Resonance Frequency Analysis (RFA) at three times: the implantation day (T1), one month (T2) and after 3 months of force application (T3).
Stability measures will be evaluated in Implant Stability Quotient (ISQ).
To assess the amount of miniscrew implant displacement, it will be used Cone Beam Computed Tomography (CBCT) at the beginning (CT1) and final of the application of orthodontic force (CT2).
Three-dimensional models will be created in specific programs and superimpositions of CT1 and CT2 will be used to measure the distance in millimeters between inicial and final position.
The evaluation will be carried out in three points: head of miniscrew implant (point C), thread (point R) and apex of miniscrew implant (point A).
The results will be statistically analyzed according to nature of the data and the significance level to be adopted will be 5%.
Тип исследования
Интервенционный
Регистрация (Действительный)
29
Фаза
- Непригодный
Критерии участия
Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.
Критерии приемлемости
Возраст, подходящий для обучения
11 лет и старше (Ребенок, Взрослый, Пожилой взрослый)
Принимает здоровых добровольцев
Да
Полы, имеющие право на обучение
Все
Описание
Inclusion Criteria:
- Patient with permanent teeth.
- Use of miniscrews in orthodontic planning.
- Miniscrews placed in the labial upper and lower posterior regions.
- Patient who agree to participate (Informed consent)
Exclusion Criteria:
- Patient with systemic disease.
- Patient with periodontal disease and/or inadequate oral hygiene.
- Use of drugs chronically.
- Patients that consume alcohol or tobacco.
- Use of fixed palatal or lingual orthodontic devices.
Учебный план
В этом разделе представлена подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.
Как устроено исследование?
Детали дизайна
- Основная цель: Поддерживающая терапия
- Распределение: Рандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Одинокий
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Экспериментальный: LLLT + immediate force
Use of Low-level laser therapy and not mediate orthodontic force application (150 gF the day of the implantation).
|
|
|
Экспериментальный: LLLT + mediate force
Use of Low-level laser therapy and mediate orthodontic force application (150 gF 4 weeks after the day of the implantation).
|
Mediate force application protocol: orthodontic force application (150 gF) 4 weeks after the day of the implantation.
|
|
Без вмешательства: Immediate force application
Not mediate orthodontic force application (150 gF the day of the implantation), without use of Low-level laser therapy.
|
|
|
Экспериментальный: Mediate force application
Mediate orthodontic force application (150 gF 4 weeks after the day of the implantation), without use of Low-level laser therapy.
|
Mediate force application protocol: orthodontic force application (150 gF) 4 weeks after the day of the implantation.
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Change from baseline miniscrew implant stability at 1 and 3 months of force application.
Временное ограничение: T1: Implantation day; T2: after 1 month; and, T3: after 3 months of force application.
|
It will be used a Resonance frequency analysis (RFA) equipment.
Stability measures will be evaluated using a unique unit of measure: Implant stability quotient (ISQ).
All groups will be evaluated the day of the implantation (T1) and after 1 month (T2).The last stability measure (T3) will be done 3 months after the implantation day in the groups without mediate force application, and 4 months after the implantation day in the groups with mediate force application.
|
T1: Implantation day; T2: after 1 month; and, T3: after 3 months of force application.
|
|
Change from baseline miniscrew implant position at 3 months of force application.
Временное ограничение: CT1: Implantation day; and, CT2: 3 months of orthodontic force application.
|
It will be used Cone Beam Computed tomography (CBCT).
Three-dimensional models will be created in specific programs and superimpositions of CT1 and CT2 will be used to measure the distance in millimeters between initial and final position.
|
CT1: Implantation day; and, CT2: 3 months of orthodontic force application.
|
Соавторы и исследователи
Здесь вы найдете людей и организации, участвующие в этом исследовании.
Спонсор
Следователи
- Главный следователь: Guido A Marañón Vásquez, DDS, University of Sao Paulo
Даты записи исследования
Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.
Изучение основных дат
Начало исследования
1 марта 2016 г.
Первичное завершение (Действительный)
1 февраля 2017 г.
Завершение исследования (Действительный)
1 августа 2017 г.
Даты регистрации исследования
Первый отправленный
23 августа 2016 г.
Впервые представлено, что соответствует критериям контроля качества
31 августа 2016 г.
Первый опубликованный (Оценивать)
7 сентября 2016 г.
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
18 января 2018 г.
Последнее отправленное обновление, отвечающее критериям контроля качества
17 января 2018 г.
Последняя проверка
1 января 2018 г.
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Другие идентификационные номера исследования
- USaoPaulo-1
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .