Influence of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew Implants

17. Januar 2018 aktualisiert von: Guido Artemio Marañón Vásquez, University of Sao Paulo

Effect of Low-level Laser Therapy on Stability and Displacement of Orthodontic Miniscrew Implants With Mediate and Immediate Force Application

The purpose of this study is to evaluate the effect of Low level laser therapy on stability and displacement of orthodontic miniscrew implants using two different force application protocols.

Studienübersicht

Detaillierte Beschreibung

The aim of this study is to evaluate the effect of Low level laser therapy (LLLT) on stability and displacement of orthodontic miniscrew implants with mediate and immediate force application. They will be assessed 48 miniscrew implants placed in patients in orthodontic treatment at the postgraduate clinical in Orthodontics, at School of Dentistry of Ribeirão Preto, University of São Paulo. They will be randomly divided into 4 groups: 1- LLLT and immediate force application; 2- LLLT and force application 4 weeks after implantation; 3- immediate force application without LLLT and 4- force application 4 weeks after implantation without LLLT. Orthodontic force of 150 gF will be applied for 3 months. A low power laser device Therapy XT with a wavelength of 660 nm and output of 100 mW immediately after implantation (energy density: 4J/cm2), and 808 nm with 100 mW (energy density: 8J/cm2), every 48 hours for two weeks in the following applications will be used. The stability will be assessed using Resonance Frequency Analysis (RFA) at three times: the implantation day (T1), one month (T2) and after 3 months of force application (T3). Stability measures will be evaluated in Implant Stability Quotient (ISQ). To assess the amount of miniscrew implant displacement, it will be used Cone Beam Computed Tomography (CBCT) at the beginning (CT1) and final of the application of orthodontic force (CT2). Three-dimensional models will be created in specific programs and superimpositions of CT1 and CT2 will be used to measure the distance in millimeters between inicial and final position. The evaluation will be carried out in three points: head of miniscrew implant (point C), thread (point R) and apex of miniscrew implant (point A). The results will be statistically analyzed according to nature of the data and the significance level to be adopted will be 5%.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

29

Phase

  • Unzutreffend

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

11 Jahre und älter (Kind, Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Ja

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Patient with permanent teeth.
  • Use of miniscrews in orthodontic planning.
  • Miniscrews placed in the labial upper and lower posterior regions.
  • Patient who agree to participate (Informed consent)

Exclusion Criteria:

  • Patient with systemic disease.
  • Patient with periodontal disease and/or inadequate oral hygiene.
  • Use of drugs chronically.
  • Patients that consume alcohol or tobacco.
  • Use of fixed palatal or lingual orthodontic devices.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Unterstützende Pflege
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Single

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: LLLT + immediate force
Use of Low-level laser therapy and not mediate orthodontic force application (150 gF the day of the implantation).
  1. Immediate post-operative period (implantation day) Red emission (660 nm) Energy density: 4 J/cm2 Power: 0.1W Irradiation area: 0,5 cm2 One application, 10 seconds of non-contact irradiation (01 point at the area surrounding the miniscrew) at a distance of 15,5 mm.
  2. Mediate post-operative period (after implantation day) Infrared emission (808 nm) Energy density: 8 J/cm2 Power: 0.1W Irradiation area: 0,5 cm2 6 applications every 48 hours after the day of implantation, 20 seconds of non-contact irradiation (01 point on the area surrounding the miniscrew) at a distance of 15,5 mm.
Experimental: LLLT + mediate force
Use of Low-level laser therapy and mediate orthodontic force application (150 gF 4 weeks after the day of the implantation).
  1. Immediate post-operative period (implantation day) Red emission (660 nm) Energy density: 4 J/cm2 Power: 0.1W Irradiation area: 0,5 cm2 One application, 10 seconds of non-contact irradiation (01 point at the area surrounding the miniscrew) at a distance of 15,5 mm.
  2. Mediate post-operative period (after implantation day) Infrared emission (808 nm) Energy density: 8 J/cm2 Power: 0.1W Irradiation area: 0,5 cm2 6 applications every 48 hours after the day of implantation, 20 seconds of non-contact irradiation (01 point on the area surrounding the miniscrew) at a distance of 15,5 mm.
Mediate force application protocol: orthodontic force application (150 gF) 4 weeks after the day of the implantation.
Kein Eingriff: Immediate force application
Not mediate orthodontic force application (150 gF the day of the implantation), without use of Low-level laser therapy.
Experimental: Mediate force application
Mediate orthodontic force application (150 gF 4 weeks after the day of the implantation), without use of Low-level laser therapy.
Mediate force application protocol: orthodontic force application (150 gF) 4 weeks after the day of the implantation.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Change from baseline miniscrew implant stability at 1 and 3 months of force application.
Zeitfenster: T1: Implantation day; T2: after 1 month; and, T3: after 3 months of force application.
It will be used a Resonance frequency analysis (RFA) equipment. Stability measures will be evaluated using a unique unit of measure: Implant stability quotient (ISQ). All groups will be evaluated the day of the implantation (T1) and after 1 month (T2).The last stability measure (T3) will be done 3 months after the implantation day in the groups without mediate force application, and 4 months after the implantation day in the groups with mediate force application.
T1: Implantation day; T2: after 1 month; and, T3: after 3 months of force application.
Change from baseline miniscrew implant position at 3 months of force application.
Zeitfenster: CT1: Implantation day; and, CT2: 3 months of orthodontic force application.
It will be used Cone Beam Computed tomography (CBCT). Three-dimensional models will be created in specific programs and superimpositions of CT1 and CT2 will be used to measure the distance in millimeters between initial and final position.
CT1: Implantation day; and, CT2: 3 months of orthodontic force application.

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Hauptermittler: Guido A Marañón Vásquez, DDS, University of Sao Paulo

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn

1. März 2016

Primärer Abschluss (Tatsächlich)

1. Februar 2017

Studienabschluss (Tatsächlich)

1. August 2017

Studienanmeldedaten

Zuerst eingereicht

23. August 2016

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

31. August 2016

Zuerst gepostet (Schätzen)

7. September 2016

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

18. Januar 2018

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

17. Januar 2018

Zuletzt verifiziert

1. Januar 2018

Mehr Informationen

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .