Sonoelastography to Predict Rotator Cuff Tears
Use Sonoelastography to Predict the Reparability of Large-to-massive Rotator Cuff Tears
Large-to-massive rotator cuff tears accounts for 30% of all rotator cuff tears. These problems can be solved by surgeries, but only part of them can be completely repaired. The prognosis for partial repair is worse than complete repair, so evaluating the possibility of complete repair is so important that it will affect the decision of treatment. More and more recent researches focused on using magnetic resonance imaging (MRI) for evaluation of fatty infiltration of rotator cuff muscles to predict the reparability of large-to-massive rotator cuff tears. However, the availability of MRI is not that good as ultrasound, so some researchers are starting to use ultrasound to predict the reparability of large-to-massive rotator cuff tears. Because it is hard to observe the tissue quality through the general ultrasound, many researchers use sonoelastography to evaluate the tissue elasticity and viability. This aim of this study is to:
- check the reliability of sonoelastography.
- associate the findings of sonoelastography to the results of MRI.
- build a predictive model for the reparability of large-to-massive rotator cuff tears.
調査の概要
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
-
Kaohsiung、台湾、833
- Kaohsiung Chang Gung Memorial Hospital
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Patients who are diagnosed with rotator cuff tear by an orthopedist.
- The large-to-massive rotator cuff tears need to be confirmed by magnetic resonance imaging or ultrasound. The definitions of this diagnosis include a tear over 3 cm or any full-thickness of tears in more than two rotator cuff muscles.
- Being willing to cooperated with the arranged examinations before the operation.
Exclusion Criteria:
- Patients who are only diagnosed with partial-thickness rotator cuff muscle tears or small- to large- sized full-thickness tears.
- Patients who have acromioclavicular arthritis that needs distal clavicle resection.
- Patients who had serious glenohumeral arthritis, pseudoparalysis, or any other shoulder trauma history.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:コホート
- 時間の展望:断面図
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Sonoelastography
時間枠:Baseline
|
This diagnostic test would be executed by a physician who has experiences of using Siemens Acuson S2000 ultrasound system for more than three year. The examination includes two of four rotator cuff muscles, listed as follows, supraspinatus muscle and infraspinatus muscle. Linear transducer (4-9 MHz) would be used for the whole test. The probe would be positioned along the longitudinal axis of the muscle belly. Compressive sonoelastography technique is used for semiquantitative analysis. In order to maintain the quality of images, quality factor needs to be over or equal to 60. The quantitative analysis was performed by shear wave sonoelastography. While assessing, the region of interest (ROI) would be divided into four quadrants. The physicians will measure the shear wave velocity for wight times at the center point of each quadrant. |
Baseline
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Passive range of motions
時間枠:Baseline
|
Passive range of motions of internal and external rotation, abduction, extension, and flexion, which are assessed by a goniometer.
|
Baseline
|
|
Muscle strength
時間枠:Baseline
|
Muscle strength assessment include the following motions, which are internal and external rotation, abduction, extension, and flexion.
They are measured by a manual dynamometer.
|
Baseline
|
|
American Shoulder and Elbow Surgeons score.
時間枠:Baseline
|
Shoulder function that are scaled by using American Shoulder and Elbow Surgeons score.
|
Baseline
|
|
MRI
時間枠:Baseline
|
MRI was performed on a 1.5T system (Signa Horizon LX, GE Healthcare) equipped with a standard shoulder surface coil.
The shoulder MRI protocol was identical for all patients and consisted of axial proton-density-weighted fast spin-echo with fat suppression sequence, the sequences was performed above the level o f the acromioclavicular joint down to below the axillary pouch with the following parameters: Coronal oblique proton-density-weighted with and without fat suppression, with axis parallel to the supraspinatus tendon, and sagittal oblique proton-density--weighted with and without fat suppression, with axis perpendicular to the coronal oblique axis, the ast spin-echo sequences were performed with the following parameters: TR msec/TE msec, 2700-4800 /25-40, echo-train length, 6; matrix, 256 × 256; field of view, 180 mm; section thickness, 2.5 mm with 2-mm gap.
No IV or intraarticular gadolinium was administered.
|
Baseline
|
|
Surgical outcome
時間枠:Baseline
|
The investigator will discuss the surgical outcome with the orthopedist to define whether the tear side is repaired partially or completely.
If the tendon can be repaired using simple side-to-side tendon repair, horizontal mattress transosseous repair via the bone trough and reduced into an anatomic position, or via the rough area of greater tuberosity (marginal converging repair), it is defined as complete repair of the tendon.
If the tendon cannot be reduced to the anatomic footprint and the orthopedist only secures re-attachment of the infraspinatus to the posterior side of greater tuberosity and/or the subscapularis of lesser tuberosity, it is defined as partial repair of the tendon.
|
Baseline
|
|
B-mode ultrasound
時間枠:Baseline
|
The ultrasound machine will be calibrated similarly using the musculoskeletal (MSK) preset and B-mode with autogain. The dynamic range will be set at 70 dB for all participants. The examiners will apply adequate transducer pressure to obtain optimal images for comparisons of muscle and bone echo. The Heckmatt scale will be used to grade the muscle echogenicity within each ROI of supraspinatus and infraspinatus muscles. The grading rule is as follows:
|
Baseline
|
協力者と研究者
捜査官
- スタディチェア:Po-Cheng Chen, MD、Chang Gung Memorial Hospital
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- CMRPG8H0811
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。