Sonoelastography to Predict Rotator Cuff Tears

2021年3月1日 更新者:Chang Gung Memorial Hospital

Use Sonoelastography to Predict the Reparability of Large-to-massive Rotator Cuff Tears

Large-to-massive rotator cuff tears accounts for 30% of all rotator cuff tears. These problems can be solved by surgeries, but only part of them can be completely repaired. The prognosis for partial repair is worse than complete repair, so evaluating the possibility of complete repair is so important that it will affect the decision of treatment. More and more recent researches focused on using magnetic resonance imaging (MRI) for evaluation of fatty infiltration of rotator cuff muscles to predict the reparability of large-to-massive rotator cuff tears. However, the availability of MRI is not that good as ultrasound, so some researchers are starting to use ultrasound to predict the reparability of large-to-massive rotator cuff tears. Because it is hard to observe the tissue quality through the general ultrasound, many researchers use sonoelastography to evaluate the tissue elasticity and viability. This aim of this study is to:

  1. check the reliability of sonoelastography.
  2. associate the findings of sonoelastography to the results of MRI.
  3. build a predictive model for the reparability of large-to-massive rotator cuff tears.

研究概览

地位

完全的

条件

研究类型

观察性的

注册 (实际的)

50

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Kaohsiung、台湾、833
        • Kaohsiung Chang Gung Memorial Hospital

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 80年 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

非概率样本

研究人群

The investigator will enroll participants with diagnosis of large-to-massive rotator cuff tears who will receive surgical repairs later, and sonoelastography and MRI are necessary for preoperative evaluation.

描述

Inclusion Criteria:

  1. Patients who are diagnosed with rotator cuff tear by an orthopedist.
  2. The large-to-massive rotator cuff tears need to be confirmed by magnetic resonance imaging or ultrasound. The definitions of this diagnosis include a tear over 3 cm or any full-thickness of tears in more than two rotator cuff muscles.
  3. Being willing to cooperated with the arranged examinations before the operation.

Exclusion Criteria:

  1. Patients who are only diagnosed with partial-thickness rotator cuff muscle tears or small- to large- sized full-thickness tears.
  2. Patients who have acromioclavicular arthritis that needs distal clavicle resection.
  3. Patients who had serious glenohumeral arthritis, pseudoparalysis, or any other shoulder trauma history.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 观测模型:队列
  • 时间观点:横截面

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Sonoelastography
大体时间:Baseline

This diagnostic test would be executed by a physician who has experiences of using Siemens Acuson S2000 ultrasound system for more than three year. The examination includes two of four rotator cuff muscles, listed as follows, supraspinatus muscle and infraspinatus muscle. Linear transducer (4-9 MHz) would be used for the whole test. The probe would be positioned along the longitudinal axis of the muscle belly.

Compressive sonoelastography technique is used for semiquantitative analysis. In order to maintain the quality of images, quality factor needs to be over or equal to 60. The quantitative analysis was performed by shear wave sonoelastography. While assessing, the region of interest (ROI) would be divided into four quadrants. The physicians will measure the shear wave velocity for wight times at the center point of each quadrant.

Baseline

次要结果测量

结果测量
措施说明
大体时间
Passive range of motions
大体时间:Baseline
Passive range of motions of internal and external rotation, abduction, extension, and flexion, which are assessed by a goniometer.
Baseline
Muscle strength
大体时间:Baseline
Muscle strength assessment include the following motions, which are internal and external rotation, abduction, extension, and flexion. They are measured by a manual dynamometer.
Baseline
American Shoulder and Elbow Surgeons score.
大体时间:Baseline
Shoulder function that are scaled by using American Shoulder and Elbow Surgeons score.
Baseline
MRI
大体时间:Baseline
MRI was performed on a 1.5T system (Signa Horizon LX, GE Healthcare) equipped with a standard shoulder surface coil. The shoulder MRI protocol was identical for all patients and consisted of axial proton-density-weighted fast spin-echo with fat suppression sequence, the sequences was performed above the level o f the acromioclavicular joint down to below the axillary pouch with the following parameters: Coronal oblique proton-density-weighted with and without fat suppression, with axis parallel to the supraspinatus tendon, and sagittal oblique proton-density--weighted with and without fat suppression, with axis perpendicular to the coronal oblique axis, the ast spin-echo sequences were performed with the following parameters: TR msec/TE msec, 2700-4800 /25-40, echo-train length, 6; matrix, 256 × 256; field of view, 180 mm; section thickness, 2.5 mm with 2-mm gap. No IV or intraarticular gadolinium was administered.
Baseline
Surgical outcome
大体时间:Baseline
The investigator will discuss the surgical outcome with the orthopedist to define whether the tear side is repaired partially or completely. If the tendon can be repaired using simple side-to-side tendon repair, horizontal mattress transosseous repair via the bone trough and reduced into an anatomic position, or via the rough area of greater tuberosity (marginal converging repair), it is defined as complete repair of the tendon. If the tendon cannot be reduced to the anatomic footprint and the orthopedist only secures re-attachment of the infraspinatus to the posterior side of greater tuberosity and/or the subscapularis of lesser tuberosity, it is defined as partial repair of the tendon.
Baseline
B-mode ultrasound
大体时间:Baseline

The ultrasound machine will be calibrated similarly using the musculoskeletal (MSK) preset and B-mode with autogain. The dynamic range will be set at 70 dB for all participants. The examiners will apply adequate transducer pressure to obtain optimal images for comparisons of muscle and bone echo. The Heckmatt scale will be used to grade the muscle echogenicity within each ROI of supraspinatus and infraspinatus muscles. The grading rule is as follows:

  1. Grade 1: Normal
  2. Grade 2: Increased muscle echo intensity with distinct bone echo
  3. Grade 3: Marked increased muscle echo with reduced bone echo
  4. Grade 4: Very strong muscle echo and complete loss of bone echo
Baseline

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 学习椅:Po-Cheng Chen, MD、Chang Gung Memorial Hospital

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2018年10月22日

初级完成 (实际的)

2020年12月31日

研究完成 (实际的)

2020年12月31日

研究注册日期

首次提交

2018年9月18日

首先提交符合 QC 标准的

2018年9月21日

首次发布 (实际的)

2018年9月25日

研究记录更新

最后更新发布 (实际的)

2021年3月3日

上次提交的符合 QC 标准的更新

2021年3月1日

最后验证

2020年2月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

在美国制造并从美国出口的产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅