Sonoelastography to Predict Rotator Cuff Tears

1. mars 2021 oppdatert av: Chang Gung Memorial Hospital

Use Sonoelastography to Predict the Reparability of Large-to-massive Rotator Cuff Tears

Large-to-massive rotator cuff tears accounts for 30% of all rotator cuff tears. These problems can be solved by surgeries, but only part of them can be completely repaired. The prognosis for partial repair is worse than complete repair, so evaluating the possibility of complete repair is so important that it will affect the decision of treatment. More and more recent researches focused on using magnetic resonance imaging (MRI) for evaluation of fatty infiltration of rotator cuff muscles to predict the reparability of large-to-massive rotator cuff tears. However, the availability of MRI is not that good as ultrasound, so some researchers are starting to use ultrasound to predict the reparability of large-to-massive rotator cuff tears. Because it is hard to observe the tissue quality through the general ultrasound, many researchers use sonoelastography to evaluate the tissue elasticity and viability. This aim of this study is to:

  1. check the reliability of sonoelastography.
  2. associate the findings of sonoelastography to the results of MRI.
  3. build a predictive model for the reparability of large-to-massive rotator cuff tears.

Studieoversikt

Status

Fullført

Intervensjon / Behandling

Studietype

Observasjonsmessig

Registrering (Faktiske)

50

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

      • Kaohsiung, Taiwan, 833
        • Kaohsiung Chang Gung Memorial Hospital

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

18 år til 80 år (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

The investigator will enroll participants with diagnosis of large-to-massive rotator cuff tears who will receive surgical repairs later, and sonoelastography and MRI are necessary for preoperative evaluation.

Beskrivelse

Inclusion Criteria:

  1. Patients who are diagnosed with rotator cuff tear by an orthopedist.
  2. The large-to-massive rotator cuff tears need to be confirmed by magnetic resonance imaging or ultrasound. The definitions of this diagnosis include a tear over 3 cm or any full-thickness of tears in more than two rotator cuff muscles.
  3. Being willing to cooperated with the arranged examinations before the operation.

Exclusion Criteria:

  1. Patients who are only diagnosed with partial-thickness rotator cuff muscle tears or small- to large- sized full-thickness tears.
  2. Patients who have acromioclavicular arthritis that needs distal clavicle resection.
  3. Patients who had serious glenohumeral arthritis, pseudoparalysis, or any other shoulder trauma history.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Observasjonsmodeller: Kohort
  • Tidsperspektiver: Tverrsnitt

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Sonoelastography
Tidsramme: Baseline

This diagnostic test would be executed by a physician who has experiences of using Siemens Acuson S2000 ultrasound system for more than three year. The examination includes two of four rotator cuff muscles, listed as follows, supraspinatus muscle and infraspinatus muscle. Linear transducer (4-9 MHz) would be used for the whole test. The probe would be positioned along the longitudinal axis of the muscle belly.

Compressive sonoelastography technique is used for semiquantitative analysis. In order to maintain the quality of images, quality factor needs to be over or equal to 60. The quantitative analysis was performed by shear wave sonoelastography. While assessing, the region of interest (ROI) would be divided into four quadrants. The physicians will measure the shear wave velocity for wight times at the center point of each quadrant.

Baseline

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Passive range of motions
Tidsramme: Baseline
Passive range of motions of internal and external rotation, abduction, extension, and flexion, which are assessed by a goniometer.
Baseline
Muscle strength
Tidsramme: Baseline
Muscle strength assessment include the following motions, which are internal and external rotation, abduction, extension, and flexion. They are measured by a manual dynamometer.
Baseline
American Shoulder and Elbow Surgeons score.
Tidsramme: Baseline
Shoulder function that are scaled by using American Shoulder and Elbow Surgeons score.
Baseline
MRI
Tidsramme: Baseline
MRI was performed on a 1.5T system (Signa Horizon LX, GE Healthcare) equipped with a standard shoulder surface coil. The shoulder MRI protocol was identical for all patients and consisted of axial proton-density-weighted fast spin-echo with fat suppression sequence, the sequences was performed above the level o f the acromioclavicular joint down to below the axillary pouch with the following parameters: Coronal oblique proton-density-weighted with and without fat suppression, with axis parallel to the supraspinatus tendon, and sagittal oblique proton-density--weighted with and without fat suppression, with axis perpendicular to the coronal oblique axis, the ast spin-echo sequences were performed with the following parameters: TR msec/TE msec, 2700-4800 /25-40, echo-train length, 6; matrix, 256 × 256; field of view, 180 mm; section thickness, 2.5 mm with 2-mm gap. No IV or intraarticular gadolinium was administered.
Baseline
Surgical outcome
Tidsramme: Baseline
The investigator will discuss the surgical outcome with the orthopedist to define whether the tear side is repaired partially or completely. If the tendon can be repaired using simple side-to-side tendon repair, horizontal mattress transosseous repair via the bone trough and reduced into an anatomic position, or via the rough area of greater tuberosity (marginal converging repair), it is defined as complete repair of the tendon. If the tendon cannot be reduced to the anatomic footprint and the orthopedist only secures re-attachment of the infraspinatus to the posterior side of greater tuberosity and/or the subscapularis of lesser tuberosity, it is defined as partial repair of the tendon.
Baseline
B-mode ultrasound
Tidsramme: Baseline

The ultrasound machine will be calibrated similarly using the musculoskeletal (MSK) preset and B-mode with autogain. The dynamic range will be set at 70 dB for all participants. The examiners will apply adequate transducer pressure to obtain optimal images for comparisons of muscle and bone echo. The Heckmatt scale will be used to grade the muscle echogenicity within each ROI of supraspinatus and infraspinatus muscles. The grading rule is as follows:

  1. Grade 1: Normal
  2. Grade 2: Increased muscle echo intensity with distinct bone echo
  3. Grade 3: Marked increased muscle echo with reduced bone echo
  4. Grade 4: Very strong muscle echo and complete loss of bone echo
Baseline

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Etterforskere

  • Studiestol: Po-Cheng Chen, MD, Chang Gung Memorial Hospital

Publikasjoner og nyttige lenker

Den som er ansvarlig for å legge inn informasjon om studien leverer frivillig disse publikasjonene. Disse kan handle om alt relatert til studiet.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

22. oktober 2018

Primær fullføring (Faktiske)

31. desember 2020

Studiet fullført (Faktiske)

31. desember 2020

Datoer for studieregistrering

Først innsendt

18. september 2018

Først innsendt som oppfylte QC-kriteriene

21. september 2018

Først lagt ut (Faktiske)

25. september 2018

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

3. mars 2021

Siste oppdatering sendt inn som oppfylte QC-kriteriene

1. mars 2021

Sist bekreftet

1. februar 2020

Mer informasjon

Begreper knyttet til denne studien

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

produkt produsert i og eksportert fra USA

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .