このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Perceptions of Porta Celiac Vascular Model

2020年5月15日 更新者:Figen GOVSA、Ege University

Ethical Committee at Researches of Ege University

Background: Primary aspect of hepatic navigation surgery is the identification of source vascular details to preserve healthy liver which has a vascularity anatomy quite challenging for the young surgeons. The purpose was to determine whether three-dimensional (3D) vascular pattern models of preoperative computed tomography images will assist resident-level trainees for hepatic surgery.

Methods: This study was based on the perception of residents who were presented with 5 different hepatic source vascular pattern and required to compare their perception level of CT, and 1:1 models in terms of importance of variability, differential of patterns and preoperative planning.

Results: All subspecialties agree that models provided better understanding of vascular source and improved preplanning. Five stations provided qualitative assessment with results showing the usefulness of porta-celiac models when used as anatomical tools in preplanning (p=0.04), simulation of interventional procedures (p=0.02), surgical education (p=0.01). None of the cases a scored less than 8.5. Responses related to understanding variations were significantly higher in the perception of the 3D model in all cases, furthermore 3D models were more useful for seniors in more complex cases 3 & 5. Some open-ended answers: "The 3D model can completely change the operation plan" One the major factors for anatomical resection of liver transplantation is the positional relationship between the hepatic arteries and the portal veins. Conclusions: The plastic-like material presenting the hepatic vascularity enables the visualization of the origin, pattern, shape, and angle of the branches with appropriate spatial perception thus making the well-structured.

調査の概要

状態

完了

介入・治療

詳細な説明

2.1. Research Design The study group consisted of Ege University, Faculty of Medicine general surgery residents (n:22). A five-station carousel composed of vascular patterns such as classical porta-celiac, portal vein type 2, portal vein type 3, separate branches origin of celiac trunk and portal vein pattern located between the right and the left hepatic artery. Each station contained the CT, and life size models of the cases. As data collection tool, a descriptive rating scale was used to evaluate the perceptions of each of the methods (CT and 3D solid model) in terms of their usefulness in knowing the variations, perceiving the problem, their effectiveness in differential diagnosis and preoperative planning.

Arterial variations were classified according to previous authors. In the classical anatomy, the common hepatic artery arises from the celiac trunk to form the gastroduodenal and proper hepatic arteries, and the latter dividing distally into right and left branches. Separate branches origin of the celiac trunk such as the artery from the abdominal aorta were modeled individually in cases of variant neighborhood. Portal variations were classified as the portal vein types. Type 1 is the classical appearance, in which the right portal vein and left portal are present as independent trunks. In type 2, the right anterior portal vein, right posterior portal vein, and left portal vein trifurcate from the main portal vein. In type 3, the right posterior portal vein comes directly from the middle portal vein, and the left portal vein and right anterior portal vein emerge from a common trunk.

The study was approved by the suitably constituted Ethical Committee at Researches Department of Ege University (18-5/45), within which the work was undertaken, and the study conforms to the Declaration of Helsinki. Clinicaltrails number is EGE18-6.134.

2.2. Selection of the samples The patients in this study were chosen among the ones who consulted to Ege University Faculty of Medicine, Department of General Surgery, Hepatobiliary Surgery and Transplantation Division for diagnose between September 2016 and January 2018. CT archives were screened and 100 eligible people (age: 18-62) with porta-celiac vascular patterns were selected. Patients whose radiological imaging results were suitable for modeling and the ones with no previous operation or pathology that may cause anatomical differences were included in the study.

2.3. Stations Five case carousel that could serve as an example for variational hepatic vascularity was defined with the consensus of experts in medical education, anatomy, radiology and liver transplantation team. The carousel included the following 5 cases.

Case 1. Portal vein with Type 3 classification pattern. Case 2. Normal classification porta-celiac vascular pattern. Case 3. Vascular pattern with the separate branch origin of celiac trunk. Case 4. Portal vein between the right and the left hepatic artery. Case 5. Portal vein with Type 2 classification pattern. 2.4. Image post-processing and segmentation DICOM data from CT and MRI sections of the patients were obtained using free 3D Slicer (version 4.10.1) software. Segmentations of the portal vein, hepatic vein, splenic vein were automatically generated from the venous phase, while the celiac trunk and hepatic artery were manually traced from the arterial phase.

2.5. Creating life-size patient-specific porta-celiac vascular model Model CT's were measured in order to verify 1:1 modelling and the printing the process was carried out with 3D printers of Mass Portal Pharaoh xd 20. Model production took a total of 24 hours; 4 for segmentation, 3 for editing, 15 for printing, and 1 hour for post-print processing. Arterial vessels were color-coded red, and the portal vein blue by the visualization team.

2.6. Quantitative assessment of model accuracy Measurements of the anatomical structures were performed and compared between the original CT images, and the CT images of the 3D model. The morphometric values such as inter-arterial distances (distances between arterial origins), inter-venous distances and the distance between the artery and the vein were noted. Measurements were compared for original CT images, the 3D rendered files, and the 3D vascular models. The repetition rate of the measurements which were done by two autonomous spectators, was 3 times at every scene and the mean values were taken as ultimate output and also calculated for further statistical analysis. The spectators performed with exceptional correlation (r=0.99, P<0.001).

2.7. Workshop During the workshop, 30-minute lectures were given by the expert team on variable vascular pattern, arterial structures relationship with venous structures and models in diagnosis. For each station, a period of 5-10 minutes was given.

2.8. Survey A multi-item survey was prepared to assess fellow's perception of residency training. The survey was utilized by our group, understanding of patient vascular anatomy, awareness of the changes based on variations, independent decision-making, differential diagnosis, plan on key surgical steps, and preparation for unexpected bleeding. The answers to the questions asked for each case were analyzed to include senior (3 years and over) - junior (1-2 years) residents.

2.9. Statistical analysis Data are entered into SPSS 24.0 for statistical analysis. Continuous variables were presented as mean ± standard deviation. Wilcoxon Signed Ranks Test was used to determine any significant differences in the measurements between the original CT images, 3D rendered images, the 3D model and CT images of the 3D model. Statistical significance was defined as a p value of less than 0.05.

研究の種類

介入

入学 (実際)

22

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • İzmir、七面鳥、35120
        • Ege University

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

25年~35年 (大人)

健康ボランティアの受け入れ

はい

受講資格のある性別

全て

説明

Inclusion Criteria: General Surgery Resident -

Exclusion Criteria: General Surgery Specialist

-

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:基礎科学
  • 介入モデル:順次割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Targeted Surgical Therapy Plan
This study pointed out that 3D surgico-anatomical models lead to more precise anatomical understanding compared to CT images in terms of detail perception. The 3D models of vascular patterns proves to be the optimal design according to the experts' evaluation with its teaching effects on surgical residents. The demonstration of the hepatic source vascular anatomy and corresponding vascular patterns may provide practically useful guides in decision making related to vascular detail during living donor liver transplantation.Model CT's were measured in order to verify 1:1 modelling and the printing the process was carried out with 3D printers of Mass Portal Pharaoh xd 20 with Eryone PLA 3D printer flament (2.2LBS)/Spool, White). Measurements of the anatomical structures were compared between the original CT images, and the CT images of the 3D model. The morphometric values such as inter-arterial distances, inter-venous distances and the distance between artery and vein were noted.
A multi-item survey was prepared to assess fellow's perception of residency training. The survey was utilized by our group, understanding of patient vascular anatomy, awareness of the changes based on variations, independent decision-making, differential diagnosis, plan on key surgical steps, and preparation for unexpected bleeding. The answers to the questions asked for each case were analyzed to include senior (3 years and over) - junior (1-2 years) residents.Assistants spend 45 minutes in the survey. Data are entered into SPSS 24.0 for statistical analysis. Wilcoxon Signed Ranks Test was used to determine any significant differences in the measurements between the original CT images, 3D rendered images, the 3D model and CT images of the 3D model. Statistical significance was defined as a p value of less than 0.05. Junior assistants stated that they perceived 2D image statistically better than 3D models compared to the senior assistants (Kruskal-Wallis Test).

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Creating life-size patient-specific porta-celiac vascular model
時間枠:05.10. 2019, 45 minutes
The survey was utilized by our group, understanding of patient vascular anatomy, awareness of the changes based on variations, independent decision-making, differential diagnosis, plan on key surgical steps, and preparation for unexpected bleeding.
05.10. 2019, 45 minutes

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • スタディチェア:Mehmet Ozer, Prof. Dr、Faculty of Medicine, Ege University
  • スタディチェア:Yelda Pinar、Faculty of Medicine, Ege University

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2018年5月5日

一次修了 (実際)

2018年11月5日

研究の完了 (実際)

2019年8月5日

試験登録日

最初に提出

2020年4月25日

QC基準を満たした最初の提出物

2020年5月15日

最初の投稿 (実際)

2020年5月20日

学習記録の更新

投稿された最後の更新 (実際)

2020年5月20日

QC基準を満たした最後の更新が送信されました

2020年5月15日

最終確認日

2020年5月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • EGE18-5/45

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

はい

IPD プランの説明

The aim was to assess whether the 3D models could be more informative than the standard CT images in predicting the real cases with different patterns. We also aimed to compare the effectiveness of the life-size model with CT screen, in 5 different porta-celiac variational cases for hepatic surgery to general surgeon residents in terms of recognizing the variational vascular source, differential diagnosis and preoperative preparation stages. It also targets to evaluate the use of these models in training and proficiency exams.

IPD 共有時間枠

Current surgical planning primarily relies on the surgeon's ability to interpret and mentally reconstruct two-dimensional (2D) CT images into 3D while planning resection margins. Although surgeons do convert what they see on flat monitors into a 3D mental design with intraoperatively expected details, each case differs from the other and 2D images are not sufficient to provide a comprehensive viewing of the vasculo-anatomical details.

IPD 共有アクセス基準

This will help liver transplantation team surgeons to review the most common hepatic vascular anatomy, allowing the simultaneous visualization in addition to providing the professionals with the material to be used in pedagogical curriculum.

IPD 共有サポート情報タイプ

  • STUDY_PROTOCOL

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

Surveyの臨床試験

3