NitrX 人工膝関節全置換術 RSA
Evolution 対 Evolution NitrX 人工膝関節全置換術システムの構成要素の移動、ポリエチレンの摩耗、および関節の炎症
Metal hypersensitivity is a recognized complication in some patients following total joint arthroplasty. This can result in a reaction to metal particles from the implants placed in the joint and cause tissue injury. The Evolution® NitrX™ (MicroPort Orthopaedics, Memphis, TN) knee implant was designed with the addition of a coating meant to create a barrier against the release of metal ions. The primary purpose of this study is to compare the Evolution and Evolution NitrX implant (implants your surgeon uses in total knee arthroplasty surgery). This study will compare the stability of these knee implants (any movement the implant makes after surgery) through the use of specialized xrays, called "radiostereometric analysis" (RSA for short). The investigators will also compare levels of circulating metal particles with blood draws and the effects of any circulating metal with MR imaging. The investigators will also be looking at the participants clinical outcomes using joint function and patient satisfaction questionnaires. A total of 50 patients will be enrolled into the study.
調査の概要
状態
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Ontario
-
London、Ontario、カナダ、N6A5A5
- London Health Sciences Centre
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Symptomatic osteoarthritis of the knee indicating primary total knee arthroplasty
- Varus knee deformity of 0 to 10 degrees
- Sufficient ligamentous function to warrant retention of the posterior cruciate ligament
- Between ages of 21 and 80 inclusive
- Patients willing and able to comply with follow-up requirements and self-evaluations
- Ability to give informed consent
- No contraindications to Magnetic Resonance Imaging (MRI)
Exclusion Criteria:
- Active or previous infection
- Medical condition precluding major surgery
- Inflammatory arthropathy
- Prior Patellectomy
- PCL deficiency
- Major Coronal plane deformity
- Valgus deformity
- Bone defects requiring augments, cones and/or stemmed implants
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:Evolution Total Knee Arthroplasty system
Patients will undergo total knee arthroplasty with the Evolution Total Knee System |
Patients will receive cemented Evolution knee system without NitrX coating for their total knee arthroplasty. |
|
実験的:Evolution with NitrX Total Knee Arthroplasty system
Patients will undergo total knee arthroplasty with the NitrX Evolution Total Knee System which has the specialized protective coating |
Patients will receive cemented Evolution knee system with NitrX coating for their total knee arthroplasty. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Implant Migration (Tibial Component)
時間枠:2 years
|
Model based Radiostereometric Analysis (RSA, specialized Xrays) will be used to register the location of the tibial implant components during supine and standing exams and measure implant movement. Changes throughout the different time points of potential tibial migration, with the use of the tibial bone beads, will be measured in millimeters. |
2 years
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Implant Migration (Femoral Component)
時間枠:2 years
|
Model based Radiostereometric Analysis (specialized Xrays) will be used to register the location of the femoral components during supine and standing exams and measure implant movement. Changes throughout the different time points of potential femoral migration, with the use of the femoral bone beads, will be measured in millimeters. |
2 years
|
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Wear Rates
時間枠:2 weeks (baseline), 6 weeks, 3 months, 6 months, 1 year, and 2 years.
|
Model based Radiostereometric Analysis (specialized Xrays) will be used to register the location of the femoral and tibial components in both standing and supine exams where the minimum joint space width between components on the medial and lateral condyles can be calculated as a measurement (in millimeters) of polyethylene wear. |
2 weeks (baseline), 6 weeks, 3 months, 6 months, 1 year, and 2 years.
|
|
Circulating metal levels
時間枠:Pre-operative, 1 and 2 years post-operatively.
|
Patients will have blood drawn and the levels of circulating cobalt, chromium, and nickel will be measured in whole blood. One vial of blood will be drawn from the patient (in milliliters). |
Pre-operative, 1 and 2 years post-operatively.
|
|
Synovial Joint Inflammation observation
時間枠:2 Years
|
Patients will complete an MRI exam using metal artefact reduction sequences. Scans will be evaluated and scored for synovial inflammation and fibrosis, indicative of reactions to metal debris, and the presence of fibrous tissue at the bone-cement-implant interface, indicative of component loosening. |
2 Years
|
|
Knee Injury and Osteoarthritis Outcome score (KOOS)
時間枠:Pre-operative, 3 months, 1 year, and 2 year post-operative
|
Patient reported outcome measure. Holds 42 items that asks patient about pain, functional daily living, and sport and recreation. Questionnaire measures levels in frequency (never to always) and severity (none to extreme). Scores are from 0-100, with higher scores indicating no knee problems. |
Pre-operative, 3 months, 1 year, and 2 year post-operative
|
|
Forgotten Joint Score (FJS)
時間枠:Pre-operative, 3 months, 1 year, and 2 year post-operative
|
Patient reported outcome measure observing the ability of a patient to forget about a joint due to successful treatment. Contains 12 items with frequency level measurement (never to mostly). The higher the score (0-100), the less aware the patient is of their affected joint when performing daily activity. |
Pre-operative, 3 months, 1 year, and 2 year post-operative
|
|
Veterans-Rand 12 Item Health Survey (VR-12)
時間枠:Pre-operative, 3 months, 1 year, and 2 year post-operative
|
Patient reported outcome measure observing physical and mental health status of patient. Contains 14 items measuring levels of severity (excellent to poor) and frequency (None of the time to Yes, all of the time). Higher scores indicate higher quality of life and vice versa. |
Pre-operative, 3 months, 1 year, and 2 year post-operative
|
|
European Quality of Life - 5 Dimension (EQ-5D)
時間枠:Pre-operative, 3 months, 1 year, and 2 year
|
Patient reported outcome measure. Standardized 5 item instrument measuring generic health status of patient. The EQ5D uses a Likert scale which assesses five states (mobility, self care, usual care, pain and discomfort and anxiety and depression) at five different levels - none(0), slight(1), moderate(2), severe(3) or unable to perform(5). Levels are coded 1-5 and an index score is then generated. Higher scores indicate higher health status of patient. |
Pre-operative, 3 months, 1 year, and 2 year
|
|
Metal Exposure/Sensitivity
時間枠:Pre-operative
|
Patient reported outcome measure. Screening tool for noting pre-operative environmental metal exposures. Questionnaire contains Yes or No questions. Higher scores would indicate greater exposure and/or metal sensitivity. |
Pre-operative
|
協力者と研究者
捜査官
- 主任研究者:Edward M Vasarhelyi, MD、London Health Sciences Centre
- 主任研究者:Matthew Teeter, PhD、London Health Science Centre
出版物と役立つリンク
一般刊行物
- Pijls BG, Plevier JWM, Nelissen RGHH. RSA migration of total knee replacements. Acta Orthop. 2018 Jun;89(3):320-328. doi: 10.1080/17453674.2018.1443635. Epub 2018 Mar 6.
- Teeter MG, Marsh JD, Howard JL, Yuan X, Vasarhelyi EM, McCalden RW, Naudie DDR. A randomized controlled trial investigating the value of patient-specific instrumentation for total knee arthroplasty in the Canadian healthcare system. Bone Joint J. 2019 May;101-B(5):565-572. doi: 10.1302/0301-620X.101B5.BJJ-2018-1323.R1.
- Teeter MG, Thoren J, Yuan X, McCalden RW, MacDonald SJ, Lanting BA, Naudie DD. Migration of a cemented fixed-bearing, polished titanium tibial baseplate (Genesis II) at ten years : a radiostereometric analysis. Bone Joint J. 2016 May;98-B(5):616-21. doi: 10.1302/0301-620X.98B5.36865.
- Teeter MG, Perry K, Yuan X, Howard JL, Lanting BA. The Effects of Resection Technique on Implant Migration in Single Radius Posterior-Stabilized Total Knee Replacement. J Knee Surg. 2020 Jan;33(1):78-83. doi: 10.1055/s-0038-1676462. Epub 2018 Dec 18.
- Sealed Envelope Ltd.2012.Power calculator for continuous outcome non0-inferiority trial.[Online] Available from: https://www.sealedenvelope.com/power/continuous-noninferios/[Accessed Thu Jan 14 2021].
- van Ijsseldijk EA, Valstar ER, Stoel BC, de Ridder R, Nelissen RG, Kaptein BL. Measuring polyethylene wear in total knee arthroplasty by RSA: differences between weight-bearing and non-weight-bearing positioning. J Orthop Res. 2014 Apr;32(4):613-7. doi: 10.1002/jor.22579. Epub 2014 Jan 7.
- Teeter MG, Wihlidal J, McCalden RW, Yuan X, MacDonald SJ, Lanting BA, Naudie DD. Radiostereometric Analysis Permits In Vivo Measurement of Very Small Levels of Wear in TKA. Clin Orthop Relat Res. 2019 Jan;477(1):80-90. doi: 10.1097/CORR.0000000000000399.
- Gascoyne T, Parashin S, Teeter M, Bohm E, Laende E, Dunbar M, Turgeon T. In vivo wear measurement in a modern total knee arthroplasty with model-based radiostereometric analysis. Bone Joint J. 2019 Nov;101-B(11):1348-1355. doi: 10.1302/0301-620X.101B11.BJJ-2018-1447.R2.
- Koff MF, Burge AJ, Potter HG. Clinical magnetic resonance imaging of arthroplasty at 1.5 T. J Orthop Res. 2020 Jul;38(7):1455-1464. doi: 10.1002/jor.24606. Epub 2020 Feb 4.
- Attard V, Li CY, Self A, Mann DA, Borthwick LA, O'Connor P, Deehan DJ, Kalson NS. Quantification of intra-articular fibrosis in patients with stiff knee arthroplasties using metal-reduction MRI. Bone Joint J. 2020 Oct;102-B(10):1331-1340. doi: 10.1302/0301-620X.102B10.BJJ-2020-0841.R1.
- Heyse TJ, Chong le R, Davis J, Boettner F, Haas SB, Potter HG. MRI analysis of the component-bone interface after TKA. Knee. 2012 Aug;19(4):290-4. doi: 10.1016/j.knee.2011.05.011. Epub 2011 Jul 8.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。