音響波形による呼吸評価 (AWARE)
呼吸器科における遠隔医療の進歩: スマートフォンのセンシングと機械学習による音響波形呼吸評価 (AWARE)
The study will evaluate the feasibility of using smartphone speakers and microphones to evaluate the caliber of the airways, detect airway obstruction, aid in airway disease diagnosis, and identify disease exacerbations.
調査の概要
詳細な説明
Asthma and COPD respectively affect millions of people in the US. Chronic lower respiratory diseases represented the fourth leading cause of death in the country before the pandemic. For these and other pulmonary diseases like cystic fibrosis (CF), monitoring disease remotely but objectively could lead to marked improvements in disease control, quality of life, and overall prognosis. However, current disease monitoring and management often rely on subjective symptom report, and objective pulmonary function tests (PFTs) are often only done a handful of times a year at subspecialty referral centers. The primary hypothesis for this study is that smartphone-based sensing and machine learning (ML) approaches can advance pulmonary telemedicine by enabling comprehensive pulmonary disease evaluation with high accuracy, reliability, and adaptability. The investigators further hypothesize that AWARE can accurately help identify different lung diseases, estimate lung function, and detect changes associated with exacerbations. In Aim 1, investigators will develop and improve a smartphone sensing approach as an accurate and reliable aide in airway disease diagnosis. Investigators will recruit a sample of healthy individuals and individuals with asthma, COPD, CF, and other airway diseases, to assess whether AWARE can accurately classify subjects in their disease groups. In Aim 2, investigators will improve the ML approach to estimate lung function accurately and adaptively, including traditional PFT indices from spirometry and impulse oscillometry. And in Aim 3, investigators will develop deep learning techniques to identify changes in airway conditions associated disease exacerbations, by performing AWARE during stable disease and acute exacerbations. For these aims, investigators will recruit a cohort of pediatric and adult subjects with a wide range of demographic and anthropometric characteristics, to have adequate representation of various airway diseases, a broad range of lung function, and the ability to obtain measurements during acute disease exacerbations. The study protocol will include study questionnaires, anthropometry, body composition, and three sets of PFTs: spirometry, oscillometry, and AWARE. A subgroup of subjects will additionally perform AWARE at home for up to two weeks, allowing investigators to evaluate supervised vs unsupervised and in-clinic vs. at-home measurements. Similarly, a subgroup of subjects will perform AWARE dual testing (i.e., with both study smartphones and their own smartphone) to evaluate repeatability using diverse equipment and software platforms.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Elizabeth Rizzi, RN
- 電話番号:317-626-6937
- メール:lizbuell@iu.edu
研究連絡先のバックアップ
- 名前:Lisa Bendy, RRT
- 電話番号:317-278-7152
- メール:lbendy@iu.edu
研究場所
-
-
Indiana
-
Indianapolis、Indiana、アメリカ、46202
- 募集
- Indiana University
-
コンタクト:
- Erick Forno, MD MPH
-
-
Pennsylvania
-
Pittsburgh、Pennsylvania、アメリカ、15224
- 募集
- University of Pittsburgh
-
コンタクト:
- Juan C Celedón, MD DrPH
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Age 8-70 years (to ensure ability to perform other PFTs; up to 75 years for COPD subjects in the UPMC adult clinic only).
- Ability to perform spirometry and oscillometry
- Signed informed consent (and assent for children as appropriate)
- No respiratory or other major disease (for healthy controls), or physician-diagnosed asthma, COPD, CF, or other airway diseases
Exclusion Criteria:
- Inability or unwillingness to perform AWARE, spirometry, or oscillometry
- Acute or chronic illness that, at the judgement of investigators, may affect lung function and alter the results of AWARE or the reference PFTs (spirometry and AOS)
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:非ランダム化
- 介入モデル:並列代入
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Asthma
Physician diagnosis plus at least one of the following in the past year: asthma symptoms that improve with albuterol; prescribed asthma controller medication(s); an acute asthma exacerbation requiring systemic steroids; or an emergency department visit or hospitalization for asthma. Alternatively, report of current asthma symptoms per US NAEPP or Global Initiative for Asthma (GINA) guidelines, plus documentation of bronchodilator response or airway hyperresponsiveness. |
AWARE testing to estimate lung function and aid in disease diagnosis |
|
実験的:Chronic Obstructive Pulmonary Disease (COPD)
Physician diagnosis, plus symptoms of COPD per GOLD guidelines, plus post-bronchodilator FEV1/FVC <0.70 or below the lower limit of normal (LLN) using GLI reference equations. |
AWARE testing to estimate lung function and aid in disease diagnosis |
|
実験的:Cystic Fibrosis (CF)
Physician diagnosis based on U.S. CF Foundation guidelines, including signs/symptoms of CF and either a positive sweat chloride test (>60 mmol/L), or an indeterminate sweat chloride test (30-59 mmol/L) plus two CF-causing CFTR mutations. The study may include subjects with different CFTR mutation classes as well as both on and off CFTR modulators. |
AWARE testing to estimate lung function and aid in disease diagnosis |
|
実験的:Other Airway Diseases
This group will include subjects with airway ciliary motility disorders, bronchiectasis, and airway malaria. Given variability in the clinical presentation and diagnosis of these conditions, they will be ascertained by physician diagnosis and reviewed by study physician investigators. |
AWARE testing to estimate lung function and aid in disease diagnosis |
|
実験的:Healthy Controls
This will include generally healthy subjects who do not have any of the airway diseases included in the study, nor other chronic cardiorespiratory or other diseases that may alter lung function or the ability to participate in the study. |
AWARE testing to estimate lung function and aid in disease diagnosis |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Accurate and reliable disease diagnosis
時間枠:Up to two weeks per subject
|
Ability of AWARE to accurately classify subjects into the study disease categories with high accuracy (>80% sensitivity and >80% overall accuracy) |
Up to two weeks per subject
|
|
Estimation of FEV1
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate FEV1 with high accuracy (<5% error compared to spirometry measures). FEV1 (forced expiratory volume in 1 second) is a measurement of how much air a person can exhale in the first second after inhaling. |
Up to two weeks per subject
|
|
Estimation of FVC
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate FVC with high accuracy (<5% error compared to spirometry measures). FVC (forced vital capacity) is a measurement of the maximum amount of air a person can exhale after a deep breath in. |
Up to two weeks per subject
|
|
Estimation of FEV1/FVC
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate FEV1/FVC with high accuracy (<5% error compared to spirometry measures). FEV1/FVC is the proportion of the forced vital capacity (FVC) that is exhaled in the first second (FEV1). |
Up to two weeks per subject
|
|
Estimation of FEF2575
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate FEF2575 with high accuracy (<5% error compared to spirometry measures). FEF25-75% is defined as forced expiratory flow over the middle one-half of the FVC (the average flow from the point at which 25% of the FVC has been exhaled to the point at which 75% of the FVC has been exhaled). |
Up to two weeks per subject
|
|
Estimation of R5
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate R5 with high accuracy (<10% error compared to oscillometry measures). R5 (also known as Rrs5), assessed by oscillometry, is the airway resistance to sound waves at a frequency of 5 Hz. |
Up to two weeks per subject
|
|
Estimation of R20
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate R20 with high accuracy (<10% error compared to oscillometry measures). R20 (also known as Rrs20), assessed by oscillometry, is the airway resistance to sound waves at a frequency of 20 Hz. |
Up to two weeks per subject
|
|
Estimation of R5-R20
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate R5-R20 with high accuracy (<10% error compared to oscillometry measures). R5-R20 (also known as Rrs5-Rrs20) is a measurement of small airway dysfunction typically assessed via oscillometry in which the difference in airway resistance to sound waves of 5 Hz and 20 Hz is calculated. |
Up to two weeks per subject
|
|
Estimation of X5
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate X5 with high accuracy (<10% error compared to oscillometry measures). X5 (also known as Xrs5), assessed by oscillometry, is the airway reactance to sound waves at a frequency of 5 Hz. |
Up to two weeks per subject
|
|
Estimation of AX
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate AX with high accuracy (<10% error compared to oscillometry measures). AX (area of reactance) is a lung function measurement of the lung's ability to store energy for passive expiration obtained via oscillometry. AX is measured by the area under the reactance curve from lowest frequency to the resonant frequency. |
Up to two weeks per subject
|
|
Identification of airway changes associated disease exacerbations
時間枠:Up to two weeks per subject
|
Ability of AWARE to identify disease exacerbations (>80% sensitivity and >80% overall accuracy). |
Up to two weeks per subject
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Reliable screening for disease diagnosis
時間枠:Up to two weeks per subject
|
Ability of AWARE to classify subjects into the study disease categories with adequate sensitivity (>70%) and accuracy (>50%) for use as a screening test |
Up to two weeks per subject
|
|
Screening of FEV1
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate FEV1 with acceptable accuracy (<10% error) for use as a screening test. |
Up to two weeks per subject
|
|
Screening of FVC
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate FVC with acceptable accuracy (<10% error) for use as a screening test |
Up to two weeks per subject
|
|
Screening of FEV1/FVC
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate FEV1/FVC with acceptable accuracy (<10% error) for use as a screening test |
Up to two weeks per subject
|
|
Screening of FEF2575
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate FEF2575 with acceptable accuracy (<10% error) for use as a screening test |
Up to two weeks per subject
|
|
Screening of R5
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate R5 with acceptable accuracy (<20% error) for use as a screening test |
Up to two weeks per subject
|
|
Screening of R20
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate R20 with acceptable accuracy (<20% error) for use as a screening test |
Up to two weeks per subject
|
|
Screening of R5-R20
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate R5-R20 with acceptable accuracy (<20% error) for use as a screening test |
Up to two weeks per subject
|
|
Screening of X5
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate X5 with acceptable accuracy (<20% error) for use as a screening test |
Up to two weeks per subject
|
|
Screening of AX
時間枠:Up to two weeks per subject
|
Ability of AWARE to estimate AX with acceptable accuracy (<20% error) for use as a screening test |
Up to two weeks per subject
|
|
Screening of airway changes associated disease exacerbations
時間枠:Up to two weeks per subject
|
Ability of AWARE to identify disease exacerbations with adequate accuracy for use as a screening test (>70% sensitivity and >50% overall accuracy) |
Up to two weeks per subject
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Erick Forno, MD MPH、Indiana University
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- 20030
- R01HL170368 (米国 NIH グラント/契約)
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。