Clinical Evaluation of Conventional and 3D-printed Implant-supported Overdentures Retained With New Attachment Systems (IODs)
調査の概要
詳細な説明
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Asyut、エジプト
- Faculty of Dental Medicine, Al-Azhar University, (Assiut Branch)
-
-
参加基準
適格基準
就学可能な年齢
- 子
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Completely edentulous patients
- Non-smokers
- Patients free from intra-oral diseases that may affect implant-overdenture prognosis
- Patients free from systemic conditions that may influence bone resorption or implant success
- Able and willing to comply with study visits and follow-up schedule
Exclusion Criteria:
- Smokers or tobacco users
- Presence of active oral lesions, infections, or mucosal pathology
- Systemic diseases affecting bone metabolism (e.g., uncontrolled diabetes, osteoporosis requiring bisphosphonates)
- History of head and neck radiation
- Severe parafunctional habits (e.g., bruxism)
- Inability to attend follow-up appointments or provide informed consent
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:ヘルスサービス研究
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Arm 1: Denture A with Locator ST Participants receive Denture A retained by Locator ST attachments.
Participants receive Denture A retained by Locator ST attachments.
|
Participants receive Denture A, a conventional mandibular implant overdenture, retained by two Locator ST attachments placed in the interforaminal region.
Outcomes include OHIP-19, VAS satisfaction, retention force, attachment wear, periodontal parameters, and denture tooth wear resistance.
|
|
実験的:Denture A with Locator EMI
Participants receive Denture A retained by two Locator EMI attachments.
Same outcome measures as above, allowing comparison of attachment type influence on patient-reported and clinical outcomes.
|
Participants receive Denture A, a conventional mandibular implant overdenture, retained by two Locator ST attachments placed in the interforaminal region.
Outcomes include OHIP-19, VAS satisfaction, retention force, attachment wear, periodontal parameters, and denture tooth wear resistance.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Retention Force of Implant Overdentures (IODs)
時間枠:Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
|
Retention force measured using a digital force gauge to quantify the dislodgement force required to remove the overdenture from the implants.
Measurements will be reported in Newtons (N).
|
Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
|
|
Denture Wear of Implant Overdentures (IODs)
時間枠:Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
|
Denture wear assessed by measuring surface loss on occlusal surface using digital analysis.
Wear depth recorded in millimeters (mm) at each evaluation point.
|
Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
|
|
Peri-implant Soft Tissue Health (Modified Plaque Index and Modified Bleeding Index Scores)
時間枠:Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
Peri-implant soft tissue health assessed using the Modified Plaque Index (mPI) and Modified Bleeding Index (mBI). Both indices are ordinal clinical scales scored according to standard peri-implant evaluation criteria: mPI range: 0-3 0 = no plaque 3 = abundant plaque mBI range: 0-3 0 = no bleeding 3 = profuse bleeding Interpretation: Higher scores indicate worse peri-implant soft tissue health. Unit of Measure: Ordinal index scores (mPI, mBI) |
Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
|
Crestal bone level changes
時間枠:Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
Crestal bone levels measured on standardized periapical radiographs taken with a paralleling technique.
Bone level is defined as the distance from the implant shoulder to the first bone-to-implant contact.
|
Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
|
Oral Health-Related Quality of Life (OHIP-19 score)
時間枠:OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
Oral health-related quality of life assessed using the Oral Health Impact Profile-19 (OHIP-19) questionnaire. The OHIP-19 consists of 19 items, each scored on a 5-point ordinal scale from 0 to 4: 0 = never 4 = very often Minimum score: 0 Maximum score: 76 Interpretation: Higher scores indicate worse oral health-related quality of life. |
OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
|
Patient Satisfaction (Visual Analog Scale Score)
時間枠:VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
Patient satisfaction with the denture and attachment system measured using a 10-point Visual Analog Scale (VAS). Participants rated their satisfaction on a scale from 0 to 10: 0 = completely dissatisfied 10 = completely satisfied |
VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
協力者と研究者
スポンサー
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
- Al-Azhar University, (Assiut B
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。