- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT07580534
Clinical Evaluation of Conventional and 3D-printed Implant-supported Overdentures Retained With New Attachment Systems (IODs)
Обзор исследования
Статус
Вмешательство/лечение
Подробное описание
Тип исследования
Регистрация (Оцененный)
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
-
Asyut, Египет
- Faculty of Dental Medicine, Al-Azhar University, (Assiut Branch)
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
- Ребенок
- Взрослый
- Пожилой взрослый
Принимает здоровых добровольцев
Описание
Inclusion Criteria:
- Completely edentulous patients
- Non-smokers
- Patients free from intra-oral diseases that may affect implant-overdenture prognosis
- Patients free from systemic conditions that may influence bone resorption or implant success
- Able and willing to comply with study visits and follow-up schedule
Exclusion Criteria:
- Smokers or tobacco users
- Presence of active oral lesions, infections, or mucosal pathology
- Systemic diseases affecting bone metabolism (e.g., uncontrolled diabetes, osteoporosis requiring bisphosphonates)
- History of head and neck radiation
- Severe parafunctional habits (e.g., bruxism)
- Inability to attend follow-up appointments or provide informed consent
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Исследования в области здравоохранения
- Распределение: Рандомизированный
- Интервенционная модель: Назначение кроссовера
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Экспериментальный: Arm 1: Denture A with Locator ST Participants receive Denture A retained by Locator ST attachments.
Participants receive Denture A retained by Locator ST attachments.
|
Participants receive Denture A, a conventional mandibular implant overdenture, retained by two Locator ST attachments placed in the interforaminal region.
Outcomes include OHIP-19, VAS satisfaction, retention force, attachment wear, periodontal parameters, and denture tooth wear resistance.
|
|
Экспериментальный: Denture A with Locator EMI
Participants receive Denture A retained by two Locator EMI attachments.
Same outcome measures as above, allowing comparison of attachment type influence on patient-reported and clinical outcomes.
|
Participants receive Denture A, a conventional mandibular implant overdenture, retained by two Locator ST attachments placed in the interforaminal region.
Outcomes include OHIP-19, VAS satisfaction, retention force, attachment wear, periodontal parameters, and denture tooth wear resistance.
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Retention Force of Implant Overdentures (IODs)
Временное ограничение: Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
|
Retention force measured using a digital force gauge to quantify the dislodgement force required to remove the overdenture from the implants.
Measurements will be reported in Newtons (N).
|
Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
|
|
Denture Wear of Implant Overdentures (IODs)
Временное ограничение: Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
|
Denture wear assessed by measuring surface loss on occlusal surface using digital analysis.
Wear depth recorded in millimeters (mm) at each evaluation point.
|
Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
|
|
Peri-implant Soft Tissue Health (Modified Plaque Index and Modified Bleeding Index Scores)
Временное ограничение: Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
Peri-implant soft tissue health assessed using the Modified Plaque Index (mPI) and Modified Bleeding Index (mBI). Both indices are ordinal clinical scales scored according to standard peri-implant evaluation criteria: mPI range: 0-3 0 = no plaque 3 = abundant plaque mBI range: 0-3 0 = no bleeding 3 = profuse bleeding Interpretation: Higher scores indicate worse peri-implant soft tissue health. Unit of Measure: Ordinal index scores (mPI, mBI) |
Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
|
Crestal bone level changes
Временное ограничение: Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
Crestal bone levels measured on standardized periapical radiographs taken with a paralleling technique.
Bone level is defined as the distance from the implant shoulder to the first bone-to-implant contact.
|
Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
|
Oral Health-Related Quality of Life (OHIP-19 score)
Временное ограничение: OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
Oral health-related quality of life assessed using the Oral Health Impact Profile-19 (OHIP-19) questionnaire. The OHIP-19 consists of 19 items, each scored on a 5-point ordinal scale from 0 to 4: 0 = never 4 = very often Minimum score: 0 Maximum score: 76 Interpretation: Higher scores indicate worse oral health-related quality of life. |
OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
|
Patient Satisfaction (Visual Analog Scale Score)
Временное ограничение: VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
Patient satisfaction with the denture and attachment system measured using a 10-point Visual Analog Scale (VAS). Participants rated their satisfaction on a scale from 0 to 10: 0 = completely dissatisfied 10 = completely satisfied |
VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
Соавторы и исследователи
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Оцененный)
Завершение исследования (Оцененный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- Al-Azhar University, (Assiut B
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .