Clinical Evaluation of Conventional and 3D-printed Implant-supported Overdentures Retained With New Attachment Systems (IODs)

torstai 7. toukokuuta 2026 päivittänyt: Mohamed Moustafa, Al-Azhar University
Randomized Crossover Clinical Trial Comparing Two Denture Designs (A and B) Retained by Two Locator Systems (ST and EMI) in Implant Overdenture Patients

Tutkimuksen yleiskatsaus

Tila

Ilmoittautuminen kutsusta

Interventio / Hoito

Yksityiskohtainen kuvaus

This randomized crossover clinical trial evaluates patient-reported outcomes and clinical performance of implant overdentures (IODs) using two different denture designs (A and B) retained by two locator attachment systems: Locator ST and Locator EMI. Each participant will receive both denture designs in a crossover sequence, allowing direct within-subject comparison.

Opintotyyppi

Interventio

Ilmoittautuminen (Arvioitu)

20

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskelupaikat

      • Asyut, Egypti
        • Faculty of Dental Medicine, Al-Azhar University, (Assiut Branch)

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Lapsi
  • Aikuinen
  • Vanhempi Aikuinen

Hyväksyy terveitä vapaaehtoisia

Ei

Kuvaus

Inclusion Criteria:

  • Completely edentulous patients
  • Non-smokers
  • Patients free from intra-oral diseases that may affect implant-overdenture prognosis
  • Patients free from systemic conditions that may influence bone resorption or implant success
  • Able and willing to comply with study visits and follow-up schedule

Exclusion Criteria:

  • Smokers or tobacco users
  • Presence of active oral lesions, infections, or mucosal pathology
  • Systemic diseases affecting bone metabolism (e.g., uncontrolled diabetes, osteoporosis requiring bisphosphonates)
  • History of head and neck radiation
  • Severe parafunctional habits (e.g., bruxism)
  • Inability to attend follow-up appointments or provide informed consent

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Terveyspalvelututkimus
  • Jako: Satunnaistettu
  • Inventiomalli: Crossover-tehtävä
  • Naamiointi: Ei mitään (avoin tarra)

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Kokeellinen: Arm 1: Denture A with Locator ST Participants receive Denture A retained by Locator ST attachments.
Participants receive Denture A retained by Locator ST attachments.
Participants receive Denture A, a conventional mandibular implant overdenture, retained by two Locator ST attachments placed in the interforaminal region. Outcomes include OHIP-19, VAS satisfaction, retention force, attachment wear, periodontal parameters, and denture tooth wear resistance.
Kokeellinen: Denture A with Locator EMI
Participants receive Denture A retained by two Locator EMI attachments. Same outcome measures as above, allowing comparison of attachment type influence on patient-reported and clinical outcomes.
Participants receive Denture A, a conventional mandibular implant overdenture, retained by two Locator ST attachments placed in the interforaminal region. Outcomes include OHIP-19, VAS satisfaction, retention force, attachment wear, periodontal parameters, and denture tooth wear resistance.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Retention Force of Implant Overdentures (IODs)
Aikaikkuna: Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
Retention force measured using a digital force gauge to quantify the dislodgement force required to remove the overdenture from the implants. Measurements will be reported in Newtons (N).
Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
Denture Wear of Implant Overdentures (IODs)
Aikaikkuna: Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
Denture wear assessed by measuring surface loss on occlusal surface using digital analysis. Wear depth recorded in millimeters (mm) at each evaluation point.
Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
Peri-implant Soft Tissue Health (Modified Plaque Index and Modified Bleeding Index Scores)
Aikaikkuna: Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months

Peri-implant soft tissue health assessed using the Modified Plaque Index (mPI) and Modified Bleeding Index (mBI).

Both indices are ordinal clinical scales scored according to standard peri-implant evaluation criteria:

mPI range: 0-3 0 = no plaque 3 = abundant plaque

mBI range: 0-3 0 = no bleeding 3 = profuse bleeding

Interpretation:

Higher scores indicate worse peri-implant soft tissue health.

Unit of Measure:

Ordinal index scores (mPI, mBI)

Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
Crestal bone level changes
Aikaikkuna: Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
Crestal bone levels measured on standardized periapical radiographs taken with a paralleling technique. Bone level is defined as the distance from the implant shoulder to the first bone-to-implant contact.
Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
Oral Health-Related Quality of Life (OHIP-19 score)
Aikaikkuna: OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up

Oral health-related quality of life assessed using the Oral Health Impact Profile-19 (OHIP-19) questionnaire. The OHIP-19 consists of 19 items, each scored on a 5-point ordinal scale from 0 to 4:

0 = never 4 = very often

Minimum score: 0 Maximum score: 76 Interpretation: Higher scores indicate worse oral health-related quality of life.

OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
Patient Satisfaction (Visual Analog Scale Score)
Aikaikkuna: VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up

Patient satisfaction with the denture and attachment system measured using a 10-point Visual Analog Scale (VAS).

Participants rated their satisfaction on a scale from 0 to 10:

0 = completely dissatisfied 10 = completely satisfied

VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Todellinen)

Lauantai 1. kesäkuuta 2024

Ensisijainen valmistuminen (Arvioitu)

Maanantai 1. kesäkuuta 2026

Opintojen valmistuminen (Arvioitu)

Lauantai 1. elokuuta 2026

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Lauantai 25. huhtikuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Torstai 7. toukokuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Tiistai 12. toukokuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Tiistai 12. toukokuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Torstai 7. toukokuuta 2026

Viimeksi vahvistettu

Keskiviikko 1. huhtikuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

EI

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .