Detaljert beskrivelse

This randomized crossover clinical trial evaluates patient-reported outcomes and clinical performance of implant overdentures (IODs) using two different denture designs (A and B) retained by two locator attachment systems: Locator ST and Locator EMI. Each participant will receive both denture designs in a crossover sequence, allowing direct within-subject comparison.

Studietype

Intervensjonell

Registrering (Antatt)

20

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

      • Asyut, Egypt
        • Faculty of Dental Medicine, Al-Azhar University, (Assiut Branch)

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Barn
  • Voksen
  • Eldre voksen

Tar imot friske frivillige

Nei

Beskrivelse

Inclusion Criteria:

  • Completely edentulous patients
  • Non-smokers
  • Patients free from intra-oral diseases that may affect implant-overdenture prognosis
  • Patients free from systemic conditions that may influence bone resorption or implant success
  • Able and willing to comply with study visits and follow-up schedule

Exclusion Criteria:

  • Smokers or tobacco users
  • Presence of active oral lesions, infections, or mucosal pathology
  • Systemic diseases affecting bone metabolism (e.g., uncontrolled diabetes, osteoporosis requiring bisphosphonates)
  • History of head and neck radiation
  • Severe parafunctional habits (e.g., bruxism)
  • Inability to attend follow-up appointments or provide informed consent

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Helsetjenesteforskning
  • Tildeling: Randomisert
  • Intervensjonsmodell: Crossover-oppdrag
  • Masking: Ingen (Open Label)

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: Arm 1: Denture A with Locator ST Participants receive Denture A retained by Locator ST attachments.
Participants receive Denture A retained by Locator ST attachments.
Participants receive Denture A, a conventional mandibular implant overdenture, retained by two Locator ST attachments placed in the interforaminal region. Outcomes include OHIP-19, VAS satisfaction, retention force, attachment wear, periodontal parameters, and denture tooth wear resistance.
Eksperimentell: Denture A with Locator EMI
Participants receive Denture A retained by two Locator EMI attachments. Same outcome measures as above, allowing comparison of attachment type influence on patient-reported and clinical outcomes.
Participants receive Denture A, a conventional mandibular implant overdenture, retained by two Locator ST attachments placed in the interforaminal region. Outcomes include OHIP-19, VAS satisfaction, retention force, attachment wear, periodontal parameters, and denture tooth wear resistance.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Retention Force of Implant Overdentures (IODs)
Tidsramme: Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
Retention force measured using a digital force gauge to quantify the dislodgement force required to remove the overdenture from the implants. Measurements will be reported in Newtons (N).
Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
Denture Wear of Implant Overdentures (IODs)
Tidsramme: Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
Denture wear assessed by measuring surface loss on occlusal surface using digital analysis. Wear depth recorded in millimeters (mm) at each evaluation point.
Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
Peri-implant Soft Tissue Health (Modified Plaque Index and Modified Bleeding Index Scores)
Tidsramme: Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months

Peri-implant soft tissue health assessed using the Modified Plaque Index (mPI) and Modified Bleeding Index (mBI).

Both indices are ordinal clinical scales scored according to standard peri-implant evaluation criteria:

mPI range: 0-3 0 = no plaque 3 = abundant plaque

mBI range: 0-3 0 = no bleeding 3 = profuse bleeding

Interpretation:

Higher scores indicate worse peri-implant soft tissue health.

Unit of Measure:

Ordinal index scores (mPI, mBI)

Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
Crestal bone level changes
Tidsramme: Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
Crestal bone levels measured on standardized periapical radiographs taken with a paralleling technique. Bone level is defined as the distance from the implant shoulder to the first bone-to-implant contact.
Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
Oral Health-Related Quality of Life (OHIP-19 score)
Tidsramme: OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up

Oral health-related quality of life assessed using the Oral Health Impact Profile-19 (OHIP-19) questionnaire. The OHIP-19 consists of 19 items, each scored on a 5-point ordinal scale from 0 to 4:

0 = never 4 = very often

Minimum score: 0 Maximum score: 76 Interpretation: Higher scores indicate worse oral health-related quality of life.

OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
Patient Satisfaction (Visual Analog Scale Score)
Tidsramme: VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up

Patient satisfaction with the denture and attachment system measured using a 10-point Visual Analog Scale (VAS).

Participants rated their satisfaction on a scale from 0 to 10:

0 = completely dissatisfied 10 = completely satisfied

VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

1. juni 2024

Primær fullføring (Antatt)

1. juni 2026

Studiet fullført (Antatt)

1. august 2026

Datoer for studieregistrering

Først innsendt

25. april 2026

Først innsendt som oppfylte QC-kriteriene

7. mai 2026

Først lagt ut (Faktiske)

12. mai 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

12. mai 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

7. mai 2026

Sist bekreftet

1. april 2026

Mer informasjon

Begreper knyttet til denne studien

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .