This Prospective Observational Study Aims to Evaluate the Capability of Ultra-high-resolution Photon-counting CT Angiography (UHR PCD-CTA) for Noninvasive Evaluation of Intracranial Venous Sinus Stents. The Study Will Compare Image Quality, Stent Visualization, Metal-related Artifacts, and Diagnosti

2026년 8월 19일 업데이트: Xin Lou

Evaluation of Ultra-High-Resolution Photon-Counting CT Angiography for Intracranial Venous Sinus Stent Assessment

This prospective observational study aims to evaluate the effectiveness of ultra-high-resolution photon-counting CT angiography (UHR PCD-CTA) for noninvasive assessment of intracranial venous sinus stents. The study will compare image quality, stent visualization, metal-related artifacts, and diagnostic accuracy between PCD-CTA and conventional energy-integrating detector CT angiography (EID-CTA).

연구 개요

상세 설명

Intracranial venous sinus stenting has become an important treatment option for patients with symptomatic venous sinus stenosis, particularly those with idiopathic intracranial hypertension. Accurate imaging follow-up after stent placement is essential for evaluating stent patency, recurrent stenosis, and potential complications such as in-stent thrombosis or occlusion.

Conventional CT angiography (CTA) is commonly used for noninvasive follow-up after venous sinus stent implantation; however, accurate assessment of stented venous sinuses remains challenging due to metal-related artifacts. Blooming artifact caused by the high attenuation of metallic stent material may result in overestimation of stent thickness and obscuration of the stent lumen. In addition, beam-hardening artifacts from the stent and adjacent skull structures may further degrade image quality and reduce diagnostic confidence, potentially limiting the ability of CTA to detect clinically significant restenosis or thrombotic complications.

연구 유형

관찰

등록 (추정된)

200

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

  • 이름: Jinhao Lyu, MD
  • 전화번호: +8615903562929
  • 이메일: 330322990@qq.com

연구 연락처 백업

연구 장소

    • Beijing Municipality
      • Beijing, Beijing Municipality, 중국, 100853
        • 모병
        • Chinese PLA General Hospital
        • 연락하다:
        • 연락하다:

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

해당 없음

샘플링 방법

비확률 샘플

연구 인구

Patients with symptomatic intracranial venous sinus stenosis

설명

Inclusion Criteria:

  • Adults aged ≥18 years.
  • History of intracranial venous sinus stent implantation.
  • Undergoing follow-up contrast-enhanced CT angiography after stent -placement.
  • Available clinical and imaging data.

Exclusion Criteria:

  • Severe motion artifacts affecting image interpretation.
  • Contraindication to iodinated contrast media.
  • Severe renal impairment preventing contrast-enhanced CT examination.
  • Incomplete imaging data.
  • Other conditions preventing reliable assessment of the venous sinus stent.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
Patients With Intracranial Venous Sinus Stenosis
Patients with symptomatic intracranial venous sinus stenosis who underwent CT angiography before and after venous sinus stent implantation.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Agreement between UHR PCD-CTA and DSA for intracranial venous sinus stent patency
기간: 1-4 years
Agreement between ultra-high-resolution photon-counting detector CT angiography (UHR PCD-CTA) and digital subtraction angiography (DSA) for the assessment of intracranial venous sinus stent patency will be quantified using Cohen's kappa (κ) coefficient. Stent patency will be classified according to the predefined diagnostic criteria, with DSA serving as the reference standard.
1-4 years

2차 결과 측정

결과 측정
측정값 설명
기간
Signal-to-noise ratio on UHR PCD-CTA
기간: 1-4years
Signal-to-noise ratio (SNR) will be calculated using CT attenuation and image noise measurements obtained from predefined regions of interest on UHR PCD-CTA images.
1-4years

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

수사관

  • 연구 의자: Xin Lou, Chinese PLA General Hospital

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 1월 7일

기본 완료 (추정된)

2029년 1월 7일

연구 완료 (추정된)

2029년 1월 7일

연구 등록 날짜

최초 제출

2026년 8월 8일

QC 기준을 충족하는 최초 제출

2026년 8월 8일

처음 게시됨 (실제)

2026년 8월 13일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 8월 20일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 8월 19일

마지막으로 확인됨

2026년 8월 1일

추가 정보

이 연구와 관련된 용어

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다