The objective of the study is to assess the superiority of the biodegradable polymer based limus-eluting stent (Nobori®) compared with the permanent polymer based everolimus-eluting stent (XIENCE V®) regarding absolute percentage of uncovered stent strut segments.
Studie Overzicht
Toestand
Voltooid
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
The mid-term efficacy of drug-eluting stents has been well-established, but there is an ongoing debate on the potential of an increased incidence of late stent thrombosis, particularly after discontinuation of thienopyridine therapy, as well as of delayed onset of restenosis or catch-up phenomenon with permanent polymer-based DES.
The extent of strut coverage with reduction of exposed thrombogenic material has been shown to be associated with the inflammatory reaction grade and with the incidence of stent thrombosis.
The optical coherence tomography (OCT) is an intravascular imaging modality based on light.
The principle is similar to intravascular ultrasound, but due to the much shorter wave length of light, it offers a much better resolution up to 10µm, enabling the exact determination of strut coverage, neointimal thickness, vessel size, presence of dissections, and even the presence of inflammation.
Studietype
Ingrijpend
Inschrijving (Werkelijk)
48
Fase
- Fase 4
Contacten en locaties
In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.
Studie Locaties
-
-
-
Munich, Duitsland, 80636
- Deutsches Herzzentrum Muenchen
-
-
Deelname Criteria
Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
18 jaar en ouder (Volwassen, Oudere volwassene)
Accepteert gezonde vrijwilligers
Nee
Geslachten die in aanmerking komen voor studie
Allemaal
Beschrijving
Inclusion Criteria:
- Patients older than age 18 with ischemic symptoms or evidence of myocardial ischemia in the presence of ≥ 50% stenosis located in native coronary vessels
- Written, informed consent by the patient or her/his legally-authorized representative for participation in the study
- In women with childbearing potential a negative pregnancy test is mandatory
Exclusion Criteria:
- Lesion length >16mm requiring a stent length >18mm
- Target lesion located in the left main trunk
- In-stent restenosis
- Acute myocardial infarction
- Malignancies or other comorbid conditions (for example severe liver, renal and pancreatic disease) with life expectancy less than 12 months or that may result in protocol non-compliance
- Known allergy to the study medications: rapamycin, everolimus, biolimus, stainless steel or cobalt chrome
- Inability to take dual antiplatelet therapy for at least 6 months
- Pregnancy (present, suspected or planned) or positive pregnancy test
- Previous enrollment in this trial
- Patient's inability to fully cooperate with the study protocol
Studie plan
Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Actieve vergelijker: Arm 1
Biodegradable polymer limus-eluting stents
|
due randomization biodegradable polymer limus-eluting stents will be implanted
Andere namen:
|
|
Actieve vergelijker: Arm 2
Permanent polymer limus-eluting stent
|
due randomization permanent polymer limus-eluting stent will be implanted
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Percentage of uncovered stent strut segments assessed by OCT
Tijdsspanne: 6-8 months
|
6-8 months
|
Secundaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Percentage of malposed stent strut segments assessed by OCT
Tijdsspanne: 6-8 months
|
6-8 months
|
Medewerkers en onderzoekers
Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.
Sponsor
Onderzoekers
- Hoofdonderzoeker: Julinda Mehilli, MD, Deutsches Herzzentrum Muenchen
Studie record data
Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.
Bestudeer belangrijke data
Studie start
1 april 2010
Primaire voltooiing (Werkelijk)
1 mei 2011
Studie voltooiing (Werkelijk)
1 mei 2011
Studieregistratiedata
Eerst ingediend
31 maart 2010
Eerst ingediend dat voldeed aan de QC-criteria
31 maart 2010
Eerst geplaatst (Schatting)
1 april 2010
Updates van studierecords
Laatste update geplaatst (Schatting)
13 januari 2012
Laatste update ingediend die voldeed aan QC-criteria
12 januari 2012
Laatst geverifieerd
1 januari 2012
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- GE IDE No. S03110
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .