Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Test Safety of Biodegradable and Permanent Limus-Eluting Stents Assessed by Optical Coherence Tomography (TEST-6-OCT)

12. januar 2012 opdateret af: Deutsches Herzzentrum Muenchen

Randomized Comparison of Limus-Eluting Stents With Biodegradable or Permanent Polymer Coating Regarding Stent Coverage Assessed by Optical Coherence Tomography

The objective of the study is to assess the superiority of the biodegradable polymer based limus-eluting stent (Nobori®) compared with the permanent polymer based everolimus-eluting stent (XIENCE V®) regarding absolute percentage of uncovered stent strut segments.

Studieoversigt

Detaljeret beskrivelse

The mid-term efficacy of drug-eluting stents has been well-established, but there is an ongoing debate on the potential of an increased incidence of late stent thrombosis, particularly after discontinuation of thienopyridine therapy, as well as of delayed onset of restenosis or catch-up phenomenon with permanent polymer-based DES. The extent of strut coverage with reduction of exposed thrombogenic material has been shown to be associated with the inflammatory reaction grade and with the incidence of stent thrombosis. The optical coherence tomography (OCT) is an intravascular imaging modality based on light. The principle is similar to intravascular ultrasound, but due to the much shorter wave length of light, it offers a much better resolution up to 10µm, enabling the exact determination of strut coverage, neointimal thickness, vessel size, presence of dissections, and even the presence of inflammation.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

48

Fase

  • Fase 4

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Munich, Tyskland, 80636
        • Deutsches Herzzentrum Muenchen

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Patients older than age 18 with ischemic symptoms or evidence of myocardial ischemia in the presence of ≥ 50% stenosis located in native coronary vessels
  • Written, informed consent by the patient or her/his legally-authorized representative for participation in the study
  • In women with childbearing potential a negative pregnancy test is mandatory

Exclusion Criteria:

  • Lesion length >16mm requiring a stent length >18mm
  • Target lesion located in the left main trunk
  • In-stent restenosis
  • Acute myocardial infarction
  • Malignancies or other comorbid conditions (for example severe liver, renal and pancreatic disease) with life expectancy less than 12 months or that may result in protocol non-compliance
  • Known allergy to the study medications: rapamycin, everolimus, biolimus, stainless steel or cobalt chrome
  • Inability to take dual antiplatelet therapy for at least 6 months
  • Pregnancy (present, suspected or planned) or positive pregnancy test
  • Previous enrollment in this trial
  • Patient's inability to fully cooperate with the study protocol

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: Arm 1
Biodegradable polymer limus-eluting stents
due randomization biodegradable polymer limus-eluting stents will be implanted
Andre navne:
  • Nobori®
Aktiv komparator: Arm 2
Permanent polymer limus-eluting stent
due randomization permanent polymer limus-eluting stent will be implanted
Andre navne:
  • Xience-V®

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Tidsramme
Percentage of uncovered stent strut segments assessed by OCT
Tidsramme: 6-8 months
6-8 months

Sekundære resultatmål

Resultatmål
Tidsramme
Percentage of malposed stent strut segments assessed by OCT
Tidsramme: 6-8 months
6-8 months

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Julinda Mehilli, MD, Deutsches Herzzentrum Muenchen

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. april 2010

Primær færdiggørelse (Faktiske)

1. maj 2011

Studieafslutning (Faktiske)

1. maj 2011

Datoer for studieregistrering

Først indsendt

31. marts 2010

Først indsendt, der opfyldte QC-kriterier

31. marts 2010

Først opslået (Skøn)

1. april 2010

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

13. januar 2012

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

12. januar 2012

Sidst verificeret

1. januar 2012

Mere information

Begreber relateret til denne undersøgelse

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Koronar hjertesygdom

Kliniske forsøg med Biodegradable polymer limus-eluting stents

Abonner