- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07563257
Comparative Evaluation of Optrell and Octaray Mapping Catheters for Conduction Block Confirmation and Voltage Assessment During Atrial Ablation
This prospective, single-center observational study aims to compare the clinical performance, workflow efficiency, and electrophysiological metrics of two commercially available, high-density multielectrode mapping catheters (Octaray and Optrell) in patients undergoing catheter ablation for complex atrial arrhythmias.
The primary focus is to determine if the real-time vector propagation capabilities of the Optrell catheter combined with V8 software can accurately confirm conduction block across linear ablation lesions without the need for full-chamber activation remapping, which is the current standard of care. A secondary focus will pair-compare the bipolar voltage amplitude distributions recorded by both catheters, given their differing electrode sizes and spacing.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
- Naam: Maxime Zabern, MD
- Telefoonnummer: +972-54-5644963
- E-mail: maximz@shamir.gov.il
Studie Contact Back-up
- Naam: Ofir Mitz
- E-mail: ofirm@shamir.gov.il
Studie Locaties
-
-
-
Be’er Ya‘aqov, Israël
- Werving
- Shamir Medical Center
-
Contact:
- Maxime Zabern, MD
- Telefoonnummer: +972-54-5644963
- E-mail: maximz@shamir.gov.il
-
Contact:
- Ofir Mitz
- E-mail: ofirm@shamir.gov.il
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- • Age ≥18 years.
- • Documented persistent atrial fibrillation and/or atrial flutter.
- • Undergoing a clinically indicated first-time (de novo) or redo catheter ablation where linear ablation lesion sets (e.g., posterior wall, roof line, lateral mitral line, CTI) are planned or anticipated.
- • Ability to provide written informed consent.
Exclusion Criteria:
- • Paroxysmal or persistent AF where only standard PVI is planned.
- • Mechanical mitral valve.
- • Presence of intracardiac thrombus or contraindication to systemic anticoagulation.
- • Any medical condition or anatomical contraindication that, in the investigator's judgment, precludes safe participation.
- • Pregnant women.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Ander
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Ander: Comparison between two mapping catheters, Optrell vs Octaray, in the same patient
|
Comparison between two mapping catheters, Optrell vs Octaray, in the same patient
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Concordance
Tijdsspanne: During ablation procedure
|
Percentage of agreement (presence vs. absence of bidirectional block) between the Optrell real-time vector assessment and standard activation remapping on a per-line basis.
|
During ablation procedure
|
|
Workflow Efficiency
Tijdsspanne: During ablation procedure
|
Difference in time (in minutes) required to confirm conduction block status using the Optrell vector method versus full activation mapping.
|
During ablation procedure
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Bipolar Voltage Correlation
Tijdsspanne: During ablation procedure
|
Statistical correlation and evaluation of systematic bias (limits of agreement) between the bipolar voltage amplitudes recorded by the two catheters in matched anatomical regions.
|
During ablation procedure
|
|
Multipolar Voltage Correlation
Tijdsspanne: During ablation procedure
|
Statistical correlation and evaluation of systematic bias (limits of agreement) between the multipolar voltage amplitudes recorded by the Optrell catheter and the bipolar voltage amplitudes recorded by the Octaray catheter in matched anatomical regions.
|
During ablation procedure
|
|
Clinical Efficacy
Tijdsspanne: 12 month follow up period
|
Freedom from any documented atrial tachyarrhythmia lasting ≥30 seconds at 1, 3, 6, 9, and 12 months
|
12 month follow up period
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Maxime Zabern, MD, Assaf-Harofeh Medical Center
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- Optrell vs Octaray
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .