Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Additive vs Subtractive Manufacturing for Endocrown Fabrication: A 24-Month RCT (ENDO-3D)

4 juni 2026 bijgewerkt door: Dina Ezz, Cairo University

Additive Versus Subtractive Manufacturing for Endocrown Fabrication: A Clinical Comparison of 3D-Printed Ceramic-Filled Photopolymer Resin and CAD/CAM Milled Resin Nano-Ceramics Endocrowns in Posterior Teeth - A 24-Month Randomized Controlled Trial

This randomized controlled trial (RCT) compares the 24-month clinical performance of endocrown restorations fabricated by two digital manufacturing pathways: additive manufacturing using 3D-printed ceramic-filled photopolymer resin (VarseoSmile TriniQ, BEGO) versus subtractive computer-aided design/computer-aided manufacturing (CAD/CAM) milling from hybrid nano-ceramic blocks (HC Hard Block, Shofu). Sixty endocrowns will be placed in endodontically treated posterior molars and evaluated using modified United States Public Health Service (USPHS) criteria at 6, 12, and 24 months. The trial is conducted at the Conservative Dentistry Department, Faculty of Dentistry, Cairo University.

Studie Overzicht

Gedetailleerde beschrijving

Post-endodontic rehabilitation of extensively damaged posterior molars using endocrowns represents a minimally invasive alternative to conventional crown-plus-post-and-core approaches. Digital fabrication has advanced both the precision and reproducibility of endocrown manufacture. While computer-aided design/computer-aided manufacturing (CAD/CAM) milled hybrid ceramic endocrowns are well-validated clinically, prospective clinical data comparing 3D-printed definitive restorations to milled counterparts are absent. This trial employs a parallel-group, 1:1 randomized design with triple blinding of participants, outcome assessors, and statistician. All restorations are delivered using Beautilink SA self-adhesive dual-cure resin cement. The primary outcome is fracture resistance at 24 months; secondary outcomes include retention, marginal adaptation, marginal discoloration, surface texture, anatomic form, color match, secondary caries, fabrication time, and patient satisfaction assessed by Visual Analogue Scale (VAS).

Studietype

Ingrijpend

Inschrijving (Geschat)

60

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Contact Back-up

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen

Accepteert gezonde vrijwilligers

Nee

Beschrijving

Inclusion Criteria:

  • Age 25-45 years, male or female
  • Endodontically treated molar tooth with radiographically confirmed treatment success and no clinical signs of failure
  • Sufficient remaining coronal structure for endocrown preparation: minimum three walls, wall thickness 1.5 mm or greater, pulp chamber depth 3 mm or greater, supragingival preparation margins
  • Completely erupted tooth with intact periodontal support
  • Minimum of 20 occluding teeth
  • Satisfactory oral hygiene status
  • Capable of providing written informed consent and committed to scheduled follow-up visits

Exclusion Criteria:

  • Diagnosed parafunctional habit or nocturnal bruxism
  • Uncontrolled systemic illness or physical disability precluding safe participation
  • Heavy tobacco use
  • Current or suspected pregnancy
  • Periapical disease or radiographic signs of endodontic failure
  • Evidence of pathological tooth wear or occlusal erosion
  • Moderate-to-severe periodontitis or tooth with hopeless prognosis
  • Radiographic or clinical evidence of vertical root fracture
  • Impaired decision-making capacity or anticipated non-compliance

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Dubbele

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: CAD/CAM Milled Endocrown
Endocrown restoration fabricated by subtractive CAD/CAM milling from HC Hard Block hybrid nano-ceramic (Shofu Inc., Japan), designed using ExoCAD software and milled on a five-axis wet-milling unit. Adhesively cemented using Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Endocrown restoration milled from HC Hard Block hybrid nano-ceramic (Shofu Inc., Japan) using a five-axis wet-milling CAD/CAM unit. Restoration designed with ExoCAD software, finished and glazed per manufacturer protocol, and cemented with Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Andere namen:
  • CAD/CAM Milled Endocrown
Experimenteel: 3D-Printed Endocrown
Endocrown restoration fabricated by additive manufacturing using VarseoSmile TriniQ ceramic-filled photopolymer resin (BEGO GmbH & Co. KG, Germany), printed on a 4K LCD printer at 30-45 degree build angle, post-cured under nitrogen atmosphere. Adhesively cemented using Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Endocrown restoration 3D-printed using VarseoSmile TriniQ ceramic-filled photopolymer resin (BEGO GmbH & Co. KG, Germany) on a 4K LCD printer at 30-45 degree build angle. Post-cured under nitrogen atmosphere, surface glazed, and cemented with Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Andere namen:
  • 3D-Printed Endocrown

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Restoration Fracture Resistance
Tijdsspanne: 24 months
Assessed using modified USPHS criteria: Alpha = absence of fracture; Bravo = minor chip amenable to repair; Charlie = catastrophic fracture, unrestorable
24 months

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Retention
Tijdsspanne: 6, 12, and 24 months
Modified USPHS: Alpha = in situ; Bravo = partial displacement; Charlie = complete loss
6, 12, and 24 months
Marginal Discoloration
Tijdsspanne: 6, 12, and 24 months
Modified USPHS: Alpha = absent; Bravo = superficial; Charlie = penetrating
6, 12, and 24 months
Surface Texture
Tijdsspanne: 6, 12, and 24 months
Modified USPHS: Alpha = smooth; Bravo = minor irregularities; Charlie = extensive breakdown
6, 12, and 24 months
Anatomic Form
Tijdsspanne: 6, 12, and 24 months
Modified USPHS: Alpha = conforms to natural contour; Bravo = discrepancy present, dentin intact; Charlie = dentin or base exposed
6, 12, and 24 months
Color Match
Tijdsspanne: 6, 12, and 24 months
Modified USPHS: Alpha = indistinguishable from adjacent tooth; Bravo = minor deviation, clinically acceptable; Charlie = obvious mismatch; Delta = gross color failure
6, 12, and 24 months
Secondary Caries
Tijdsspanne: 6, 12, and 24 months
Modified USPHS: Alpha = absent; Charlie = present
6, 12, and 24 months
Fabrication Time
Tijdsspanne: Periprocedural
Time in minutes from CAD design completion to restoration readiness for cementation
Periprocedural
Patient Satisfaction
Tijdsspanne: 6, 12, and 24 months
Visual Analogue Scale 0-100 mm; 0 = entirely dissatisfied, 100 = entirely satisfied
6, 12, and 24 months

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Algemene publicaties

  • Abou-Steit S, Ibrahim SH, Salem M. Three years clinical evaluation of lithium disilicate and hybrid nano-ceramic CAD/CAM endocrowns (randomized clinical trial). Egyptian Dental Journal 2024;70:551-561.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Geschat)

1 juni 2026

Primaire voltooiing (Geschat)

1 juni 2028

Studie voltooiing (Geschat)

1 september 2028

Studieregistratiedata

Eerst ingediend

30 mei 2026

Eerst ingediend dat voldeed aan de QC-criteria

4 juni 2026

Eerst geplaatst (Werkelijk)

8 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

8 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

4 juni 2026

Laatst geverifieerd

1 juni 2026

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • /4/26 3D-Printed vs CAD/CAM

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren