Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Additive vs Subtractive Manufacturing for Endocrown Fabrication: A 24-Month RCT (ENDO-3D)

4. Juni 2026 aktualisiert von: Dina Ezz, Cairo University

Additive Versus Subtractive Manufacturing for Endocrown Fabrication: A Clinical Comparison of 3D-Printed Ceramic-Filled Photopolymer Resin and CAD/CAM Milled Resin Nano-Ceramics Endocrowns in Posterior Teeth - A 24-Month Randomized Controlled Trial

This randomized controlled trial (RCT) compares the 24-month clinical performance of endocrown restorations fabricated by two digital manufacturing pathways: additive manufacturing using 3D-printed ceramic-filled photopolymer resin (VarseoSmile TriniQ, BEGO) versus subtractive computer-aided design/computer-aided manufacturing (CAD/CAM) milling from hybrid nano-ceramic blocks (HC Hard Block, Shofu). Sixty endocrowns will be placed in endodontically treated posterior molars and evaluated using modified United States Public Health Service (USPHS) criteria at 6, 12, and 24 months. The trial is conducted at the Conservative Dentistry Department, Faculty of Dentistry, Cairo University.

Studienübersicht

Detaillierte Beschreibung

Post-endodontic rehabilitation of extensively damaged posterior molars using endocrowns represents a minimally invasive alternative to conventional crown-plus-post-and-core approaches. Digital fabrication has advanced both the precision and reproducibility of endocrown manufacture. While computer-aided design/computer-aided manufacturing (CAD/CAM) milled hybrid ceramic endocrowns are well-validated clinically, prospective clinical data comparing 3D-printed definitive restorations to milled counterparts are absent. This trial employs a parallel-group, 1:1 randomized design with triple blinding of participants, outcome assessors, and statistician. All restorations are delivered using Beautilink SA self-adhesive dual-cure resin cement. The primary outcome is fracture resistance at 24 months; secondary outcomes include retention, marginal adaptation, marginal discoloration, surface texture, anatomic form, color match, secondary caries, fabrication time, and patient satisfaction assessed by Visual Analogue Scale (VAS).

Studientyp

Interventionell

Einschreibung (Geschätzt)

60

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studieren Sie die Kontaktsicherung

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  • Age 25-45 years, male or female
  • Endodontically treated molar tooth with radiographically confirmed treatment success and no clinical signs of failure
  • Sufficient remaining coronal structure for endocrown preparation: minimum three walls, wall thickness 1.5 mm or greater, pulp chamber depth 3 mm or greater, supragingival preparation margins
  • Completely erupted tooth with intact periodontal support
  • Minimum of 20 occluding teeth
  • Satisfactory oral hygiene status
  • Capable of providing written informed consent and committed to scheduled follow-up visits

Exclusion Criteria:

  • Diagnosed parafunctional habit or nocturnal bruxism
  • Uncontrolled systemic illness or physical disability precluding safe participation
  • Heavy tobacco use
  • Current or suspected pregnancy
  • Periapical disease or radiographic signs of endodontic failure
  • Evidence of pathological tooth wear or occlusal erosion
  • Moderate-to-severe periodontitis or tooth with hopeless prognosis
  • Radiographic or clinical evidence of vertical root fracture
  • Impaired decision-making capacity or anticipated non-compliance

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Aktiver Komparator: CAD/CAM Milled Endocrown
Endocrown restoration fabricated by subtractive CAD/CAM milling from HC Hard Block hybrid nano-ceramic (Shofu Inc., Japan), designed using ExoCAD software and milled on a five-axis wet-milling unit. Adhesively cemented using Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Endocrown restoration milled from HC Hard Block hybrid nano-ceramic (Shofu Inc., Japan) using a five-axis wet-milling CAD/CAM unit. Restoration designed with ExoCAD software, finished and glazed per manufacturer protocol, and cemented with Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Andere Namen:
  • CAD/CAM Milled Endocrown
Experimental: 3D-Printed Endocrown
Endocrown restoration fabricated by additive manufacturing using VarseoSmile TriniQ ceramic-filled photopolymer resin (BEGO GmbH & Co. KG, Germany), printed on a 4K LCD printer at 30-45 degree build angle, post-cured under nitrogen atmosphere. Adhesively cemented using Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Endocrown restoration 3D-printed using VarseoSmile TriniQ ceramic-filled photopolymer resin (BEGO GmbH & Co. KG, Germany) on a 4K LCD printer at 30-45 degree build angle. Post-cured under nitrogen atmosphere, surface glazed, and cemented with Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Andere Namen:
  • 3D-Printed Endocrown

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Restoration Fracture Resistance
Zeitfenster: 24 months
Assessed using modified USPHS criteria: Alpha = absence of fracture; Bravo = minor chip amenable to repair; Charlie = catastrophic fracture, unrestorable
24 months

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Retention
Zeitfenster: 6, 12, and 24 months
Modified USPHS: Alpha = in situ; Bravo = partial displacement; Charlie = complete loss
6, 12, and 24 months
Marginal Discoloration
Zeitfenster: 6, 12, and 24 months
Modified USPHS: Alpha = absent; Bravo = superficial; Charlie = penetrating
6, 12, and 24 months
Surface Texture
Zeitfenster: 6, 12, and 24 months
Modified USPHS: Alpha = smooth; Bravo = minor irregularities; Charlie = extensive breakdown
6, 12, and 24 months
Anatomic Form
Zeitfenster: 6, 12, and 24 months
Modified USPHS: Alpha = conforms to natural contour; Bravo = discrepancy present, dentin intact; Charlie = dentin or base exposed
6, 12, and 24 months
Color Match
Zeitfenster: 6, 12, and 24 months
Modified USPHS: Alpha = indistinguishable from adjacent tooth; Bravo = minor deviation, clinically acceptable; Charlie = obvious mismatch; Delta = gross color failure
6, 12, and 24 months
Secondary Caries
Zeitfenster: 6, 12, and 24 months
Modified USPHS: Alpha = absent; Charlie = present
6, 12, and 24 months
Fabrication Time
Zeitfenster: Periprocedural
Time in minutes from CAD design completion to restoration readiness for cementation
Periprocedural
Patient Satisfaction
Zeitfenster: 6, 12, and 24 months
Visual Analogue Scale 0-100 mm; 0 = entirely dissatisfied, 100 = entirely satisfied
6, 12, and 24 months

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Publikationen und hilfreiche Links

Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.

Allgemeine Veröffentlichungen

  • Abou-Steit S, Ibrahim SH, Salem M. Three years clinical evaluation of lithium disilicate and hybrid nano-ceramic CAD/CAM endocrowns (randomized clinical trial). Egyptian Dental Journal 2024;70:551-561.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

1. Juni 2026

Primärer Abschluss (Geschätzt)

1. Juni 2028

Studienabschluss (Geschätzt)

1. September 2028

Studienanmeldedaten

Zuerst eingereicht

30. Mai 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

4. Juni 2026

Zuerst gepostet (Tatsächlich)

8. Juni 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

8. Juni 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

4. Juni 2026

Zuletzt verifiziert

1. Juni 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • /4/26 3D-Printed vs CAD/CAM

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur CAD/CAM Milled HC Hard Block Endocrown

Abonnieren