Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Additive vs Subtractive Manufacturing for Endocrown Fabrication: A 24-Month RCT (ENDO-3D)

4 giugno 2026 aggiornato da: Dina Ezz, Cairo University

Additive Versus Subtractive Manufacturing for Endocrown Fabrication: A Clinical Comparison of 3D-Printed Ceramic-Filled Photopolymer Resin and CAD/CAM Milled Resin Nano-Ceramics Endocrowns in Posterior Teeth - A 24-Month Randomized Controlled Trial

This randomized controlled trial (RCT) compares the 24-month clinical performance of endocrown restorations fabricated by two digital manufacturing pathways: additive manufacturing using 3D-printed ceramic-filled photopolymer resin (VarseoSmile TriniQ, BEGO) versus subtractive computer-aided design/computer-aided manufacturing (CAD/CAM) milling from hybrid nano-ceramic blocks (HC Hard Block, Shofu). Sixty endocrowns will be placed in endodontically treated posterior molars and evaluated using modified United States Public Health Service (USPHS) criteria at 6, 12, and 24 months. The trial is conducted at the Conservative Dentistry Department, Faculty of Dentistry, Cairo University.

Panoramica dello studio

Descrizione dettagliata

Post-endodontic rehabilitation of extensively damaged posterior molars using endocrowns represents a minimally invasive alternative to conventional crown-plus-post-and-core approaches. Digital fabrication has advanced both the precision and reproducibility of endocrown manufacture. While computer-aided design/computer-aided manufacturing (CAD/CAM) milled hybrid ceramic endocrowns are well-validated clinically, prospective clinical data comparing 3D-printed definitive restorations to milled counterparts are absent. This trial employs a parallel-group, 1:1 randomized design with triple blinding of participants, outcome assessors, and statistician. All restorations are delivered using Beautilink SA self-adhesive dual-cure resin cement. The primary outcome is fracture resistance at 24 months; secondary outcomes include retention, marginal adaptation, marginal discoloration, surface texture, anatomic form, color match, secondary caries, fabrication time, and patient satisfaction assessed by Visual Analogue Scale (VAS).

Tipo di studio

Interventistico

Iscrizione (Stimato)

60

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto

Accetta volontari sani

No

Descrizione

Inclusion Criteria:

  • Age 25-45 years, male or female
  • Endodontically treated molar tooth with radiographically confirmed treatment success and no clinical signs of failure
  • Sufficient remaining coronal structure for endocrown preparation: minimum three walls, wall thickness 1.5 mm or greater, pulp chamber depth 3 mm or greater, supragingival preparation margins
  • Completely erupted tooth with intact periodontal support
  • Minimum of 20 occluding teeth
  • Satisfactory oral hygiene status
  • Capable of providing written informed consent and committed to scheduled follow-up visits

Exclusion Criteria:

  • Diagnosed parafunctional habit or nocturnal bruxism
  • Uncontrolled systemic illness or physical disability precluding safe participation
  • Heavy tobacco use
  • Current or suspected pregnancy
  • Periapical disease or radiographic signs of endodontic failure
  • Evidence of pathological tooth wear or occlusal erosion
  • Moderate-to-severe periodontitis or tooth with hopeless prognosis
  • Radiographic or clinical evidence of vertical root fracture
  • Impaired decision-making capacity or anticipated non-compliance

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Doppio

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Comparatore attivo: CAD/CAM Milled Endocrown
Endocrown restoration fabricated by subtractive CAD/CAM milling from HC Hard Block hybrid nano-ceramic (Shofu Inc., Japan), designed using ExoCAD software and milled on a five-axis wet-milling unit. Adhesively cemented using Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Endocrown restoration milled from HC Hard Block hybrid nano-ceramic (Shofu Inc., Japan) using a five-axis wet-milling CAD/CAM unit. Restoration designed with ExoCAD software, finished and glazed per manufacturer protocol, and cemented with Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Altri nomi:
  • CAD/CAM Milled Endocrown
Sperimentale: 3D-Printed Endocrown
Endocrown restoration fabricated by additive manufacturing using VarseoSmile TriniQ ceramic-filled photopolymer resin (BEGO GmbH & Co. KG, Germany), printed on a 4K LCD printer at 30-45 degree build angle, post-cured under nitrogen atmosphere. Adhesively cemented using Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Endocrown restoration 3D-printed using VarseoSmile TriniQ ceramic-filled photopolymer resin (BEGO GmbH & Co. KG, Germany) on a 4K LCD printer at 30-45 degree build angle. Post-cured under nitrogen atmosphere, surface glazed, and cemented with Beautilink SA self-adhesive dual-cure resin cement (Shofu Inc., Japan).
Altri nomi:
  • 3D-Printed Endocrown

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Restoration Fracture Resistance
Lasso di tempo: 24 months
Assessed using modified USPHS criteria: Alpha = absence of fracture; Bravo = minor chip amenable to repair; Charlie = catastrophic fracture, unrestorable
24 months

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Retention
Lasso di tempo: 6, 12, and 24 months
Modified USPHS: Alpha = in situ; Bravo = partial displacement; Charlie = complete loss
6, 12, and 24 months
Marginal Discoloration
Lasso di tempo: 6, 12, and 24 months
Modified USPHS: Alpha = absent; Bravo = superficial; Charlie = penetrating
6, 12, and 24 months
Surface Texture
Lasso di tempo: 6, 12, and 24 months
Modified USPHS: Alpha = smooth; Bravo = minor irregularities; Charlie = extensive breakdown
6, 12, and 24 months
Anatomic Form
Lasso di tempo: 6, 12, and 24 months
Modified USPHS: Alpha = conforms to natural contour; Bravo = discrepancy present, dentin intact; Charlie = dentin or base exposed
6, 12, and 24 months
Color Match
Lasso di tempo: 6, 12, and 24 months
Modified USPHS: Alpha = indistinguishable from adjacent tooth; Bravo = minor deviation, clinically acceptable; Charlie = obvious mismatch; Delta = gross color failure
6, 12, and 24 months
Secondary Caries
Lasso di tempo: 6, 12, and 24 months
Modified USPHS: Alpha = absent; Charlie = present
6, 12, and 24 months
Fabrication Time
Lasso di tempo: Periprocedural
Time in minutes from CAD design completion to restoration readiness for cementation
Periprocedural
Patient Satisfaction
Lasso di tempo: 6, 12, and 24 months
Visual Analogue Scale 0-100 mm; 0 = entirely dissatisfied, 100 = entirely satisfied
6, 12, and 24 months

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Pubblicazioni generali

  • Abou-Steit S, Ibrahim SH, Salem M. Three years clinical evaluation of lithium disilicate and hybrid nano-ceramic CAD/CAM endocrowns (randomized clinical trial). Egyptian Dental Journal 2024;70:551-561.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 giugno 2026

Completamento primario (Stimato)

1 giugno 2028

Completamento dello studio (Stimato)

1 settembre 2028

Date di iscrizione allo studio

Primo inviato

30 maggio 2026

Primo inviato che soddisfa i criteri di controllo qualità

4 giugno 2026

Primo Inserito (Effettivo)

8 giugno 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

8 giugno 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

4 giugno 2026

Ultimo verificato

1 giugno 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • /4/26 3D-Printed vs CAD/CAM

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su CAD/CAM Milled HC Hard Block Endocrown

Sottoscrivi