Digital Breast Tomosynthesis Versus Digital Mammography: A National Multicenter Trial

31 stycznia 2012 zaktualizowane przez: Thomas Moritz, Medical University of Vienna

Digital Breast Tomosynthesis vs. Digital Mammography: A National Multicenter Trial

The goal of this study is to determine the value of the new mammography technique called Digital Breast Tomosynthesis (DBT) compared to the current standard technique Digital Mammography for the early detection of Breast Cancer.

DBT is able to compute a three-dimensional image of a breast from several low-dose mammographies taken from different angles while the device is moving around the breast in a circular motion. This should overcome a significant limitation of Digital Mammography arising from the masking of breast cancer in a mammography image caused by overlying normal breast tissue.

This is a study conducted in several Austrian Breast Imaging Centers.

Przegląd badań

Status

Nieznany

Szczegółowy opis

This prospective national multicenter multivendor trial aims at determining the impact of the novel technique Digital Breast Tomosynthesis (DBT) in the assessment and screening for breast cancer. Mammography is the primary imaging modality for the early detection of clinically occult breast cancer.

Despite advances in mammographic technique, mammography is still limited with regard to both sensitivity and specificity. In the majority of cases these limitations arise from the masking of subtle breast cancer lesions by overlapping breast tissue.

DBT is a novel technique that tries to overcome these limitations by performing a 3D-reconstruction of breast tissue from multiple low-dose digital mammographic images acquired in several planes in a 15 to 50 degree angle.

Early studies indicate an advantage of DBT compared to the standard Full Field Digital Mammography (FFDM) in terms of an improvement of specificity without cutback in sensitivity.

Controversy continues over the use of DBT in combination with FFDM or as a standalone screening method without concomitant 2D imaging. Unfortunately, the peer-reviewed publications evaluating DBT are limited and consist of single institution studies with a small number of participants.

The purpose of this study is to evaluate the novel technique of DBT compared to routine FFDM in a clinical large sample study (600 participants) to provide the path to implementation of this new technique into clinical and screening routine.

Typ studiów

Obserwacyjny

Zapisy (Oczekiwany)

600

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

      • Vienna, Austria, A-1090
      • Vienna, Austria, A-1100
      • Vienna, Austria, A-1140
        • Rekrutacyjny
        • Hanusch Krankenhaus
        • Kontakt:
    • Styria
      • Graz, Styria, Austria, A-8036
    • Upper Austria
      • Wels, Upper Austria, Austria, A-4600

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

25 lat i starsze (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Tak

Płeć kwalifikująca się do nauki

Kobieta

Metoda próbkowania

Próbka bez prawdopodobieństwa

Badana populacja

The study population consists of two groups:

One screening group consisting of asymptomatic women (Age 40+) referred for a screening mammography examination.

The second group consists of women aged 25+ referred for further examination of a breast lesion.

Opis

Inclusion Criteria:

  • Age > 25 years (40 years or older for Screening Cohort)
  • No history of breast cancer
  • Written informed consent
  • Asymptomatic women in follow up for early detection of breast cancer or
  • Patients with a recent positive mammography (BI-RADS 3-5)

Exclusion Criteria:

  • Pregnant and breast feeding women
  • Unable to tolerate breast compression
  • Breast implants
  • Unable to understand or execute written informed consent

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Kohorty i interwencje

Grupa / Kohorta
Breast Cancer Screening Patients
Group 1 consists of Women referred to Breast Cancer Screening examinations at a participating Austrian Breast Imaging Site
Diagnostic Patients
Patients referred to a participating Breast Imaging Center for a clinically or radiologically detected breast lesion

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Ramy czasowe
Specificity of Digital Breast Tomosynthesis in the characterization of Breast lesions
Ramy czasowe: One year
One year

Miary wyników drugorzędnych

Miara wyniku
Ramy czasowe
Sensitivity of Digital Breast Tomosynthesis in the detection of malignant breast lesions
Ramy czasowe: One year
One year

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Główny śledczy: Thomas Moritz, MD, Medical University of Vienna
  • Dyrektor Studium: Thomas Helbich, MD Prof. MBA MSc, Medical University of Vienna

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów

1 stycznia 2012

Zakończenie podstawowe (Oczekiwany)

1 września 2012

Ukończenie studiów (Oczekiwany)

1 grudnia 2012

Daty rejestracji na studia

Pierwszy przesłany

29 stycznia 2012

Pierwszy przesłany, który spełnia kryteria kontroli jakości

31 stycznia 2012

Pierwszy wysłany (Oszacować)

1 lutego 2012

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Oszacować)

1 lutego 2012

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

31 stycznia 2012

Ostatnia weryfikacja

1 stycznia 2012

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • TomoTrial001

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

3
Subskrybuj