Randomized Comparison of Radiological Exposure With TRIPTable® in Patients With Acute Coronary Syndromes (TRIPTABLE)
Randomized Comparison of Radiological Exposure Between Radial and Femoral Technique Assessing Use of Protective Device Dedicated TRIPTable® in Patients With Acute Coronary Syndromes Undergoing Cardiac Catheterization
Excessive radiation received by the operator has been described as a possible drawback of the radial catheterization technique when compared with the femoral access.
The study hypothesis is that the use of radial access device dedicated radioprotective TRIPTable ® (Transradial Intervention Table Protection) is not inferior to standard femoral technique and superior to standard radial technique as radioprotection strategy to the operator in patients with acute coronary syndromes acute and submitted to cardiac catheterization.
Przegląd badań
Status
Interwencja / Leczenie
Szczegółowy opis
This study is prospective, 1:1:1 randomized, unicentric, comparative between femoral and radial radial technique with and without dedicated TRIPTable ® device.
The TripTable device is a polycarbonate support table anatomically-designed to facilitate the radial technique, facilitating the puncturing, positioning, support to work material and providing further radioprotection from a lead layer without obstruction in viewing the fluoroscopic images.
Typ studiów
Zapisy (Oczekiwany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
SP
-
Marilia, SP, Brazylia, 17514410
- Marilia School of Medicine
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Unstable angina with an indication for invasive stratification
- Acute coronary syndrome without ST-segment elevation
- Acute coronary syndrome with ST-segment elevation
- Patient informed of the nature of the study and have signed the Informed Consent
- Patient suitable for coronary angiography and / or percutaneous coronary intervention either by radial access as the femoral
Exclusion Criteria:
- Below 18 years of age
- Pregnancy
- Chronic use of vitamin K antagonists, or direct thrombin inhibitors or antagonists of factor Xa,
- Active bleeding or high risk of bleeding (severe hepatic insufficiency, active peptic ulcer disease, creatinine clearance <30 mL / min, platelet count <100,000 mm3);
- Uncontrolled hypertension;
- Cardiogenic shock;
- Previous coronary artery bypass graft surgery with the use of ≥ 1 graft
- Patients not candidates for the use of any of the specified vascular access
- Concomitant severe disease with life expectancy less than 12 months life;
- Medical, geographical, or social conditions that impede study participation
- Refusal or inability to understand and sign the informed consent form.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: Radial
Cardiac catheterization and coronary angioplasty performed via standard radial artery technique.
|
Standard radial artery catheterization procedure, performed for the purpose of coronary angiography and ad hoc angioplasty if necessary.
Inne nazwy:
|
|
Aktywny komparator: Femoral
Cardiac catheterization and coronary angioplasty performed via standard femoral artery technique.
|
Standard femoral artery catheterization procedure, performed for the purpose of coronary angiography and ad hoc angioplasty if necessary.
The supporting device will be the patient's own body, placing the material above the legs.
|
|
Eksperymentalny: TripTable
Cardiac catheterization and coronary angioplasty performed with standard transradial technique plus using the TRIPTable device.
|
Details of the device previously described, designed to medical operator radioprotection.
No changes in radial technique beyond the use of the supportive device will be performed.
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Radiation dose
Ramy czasowe: 1 year
|
Accumulated radiation dose received by the operator during the interventional cardiology procedures as measured by Thermoluminescent Dosimeters (TLD)
|
1 year
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Radiation according measured site
Ramy czasowe: 1 year
|
accumulated radiation dose received by each measured site (gonadal, thyroid and lens)
|
1 year
|
|
Operator absorbed radiation according total radiation dose
Ramy czasowe: 1 year
|
Evaluation of radiation dose to the operator according to linear correlation corrected for total dose of radiation.
|
1 year
|
|
Success of procedure
Ramy czasowe: 1 year
|
Success rate of the procedure, as defined by perform the procedure without need to cross between techniques
|
1 year
|
Inne miary wyników
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Clinical data
Ramy czasowe: 1 year
|
Registration of clinical features and procedural data, to compare with historical control group (ARISE trial - NCT01653587) using similar inclusion criteria without the objectives of the current study operator (to exclude Hawthorne effect).
|
1 year
|
Współpracownicy i badacze
Sponsor
Śledczy
- Dyrektor Studium: Igor RC Bienert, MD, Marilia School of Medicine
Publikacje i pomocne linki
Publikacje ogólne
- Chambers CE, Fetterly KA, Holzer R, Lin PJ, Blankenship JC, Balter S, Laskey WK. Radiation safety program for the cardiac catheterization laboratory. Catheter Cardiovasc Interv. 2011 Mar 1;77(4):546-56. doi: 10.1002/ccd.22867. Epub 2011 Jan 19.
- Sciahbasi A, Romagnoli E, Trani C, Burzotta F, Sarandrea A, Summaria F, Patrizi R, Rao S, Lioy E. Operator radiation exposure during percutaneous coronary procedures through the left or right radial approach: the TALENT dosimetric substudy. Circ Cardiovasc Interv. 2011 Jun;4(3):226-31. doi: 10.1161/CIRCINTERVENTIONS.111.961185. Epub 2011 May 17.
- Sciahbasi A, Calabro P, Sarandrea A, Rigattieri S, Tomassini F, Sardella G, Zavalloni D, Cortese B, Limbruno U, Tebaldi M, Gagnor A, Rubartelli P, Zingarelli A, Valgimigli M. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX). Cardiovasc Revasc Med. 2014 Jun;15(4):209-13. doi: 10.1016/j.carrev.2014.03.010. Epub 2014 Mar 26.
- Park EY, Shroff AR, Crisco LV, Vidovich MI. A review of radiation exposures associated with radial cardiac catheterisation. EuroIntervention. 2013 Oct;9(6):745-53. doi: 10.4244/EIJV9I6A119.
- de Andrade PB, E Mattos LA, Tebet MA, Rinaldi FS, Esteves VC, Nogueira EF, Franca JI, de Andrade MV, Barbosa RA, Labrunie A, Abizaid AA, Sousa AG. Design and rationale of the AngioSeal versus the Radial approach In acute coronary SyndromE (ARISE) trial: a randomized comparison of a vascular closure device versus the radial approach to prevent vascular access site complications in non-ST-segment elevation acute coronary syndrome patients. Trials. 2013 Dec 18;14:435. doi: 10.1186/1745-6215-14-435.
- Jolly SS, Yusuf S, Cairns J, Niemela K, Xavier D, Widimsky P, Budaj A, Niemela M, Valentin V, Lewis BS, Avezum A, Steg PG, Rao SV, Gao P, Afzal R, Joyner CD, Chrolavicius S, Mehta SR; RIVAL trial group. Radial versus femoral access for coronary angiography and intervention in patients with acute coronary syndromes (RIVAL): a randomised, parallel group, multicentre trial. Lancet. 2011 Apr 23;377(9775):1409-20. doi: 10.1016/S0140-6736(11)60404-2. Epub 2011 Apr 4. Erratum In: Lancet. 2011 Apr 23;377(9775):1408. Lancet. 2011 Jul 2;378(9785):30.
- Romagnoli E, Biondi-Zoccai G, Sciahbasi A, Politi L, Rigattieri S, Pendenza G, Summaria F, Patrizi R, Borghi A, Di Russo C, Moretti C, Agostoni P, Loschiavo P, Lioy E, Sheiban I, Sangiorgi G. Radial versus femoral randomized investigation in ST-segment elevation acute coronary syndrome: the RIFLE-STEACS (Radial Versus Femoral Randomized Investigation in ST-Elevation Acute Coronary Syndrome) study. J Am Coll Cardiol. 2012 Dec 18;60(24):2481-9. doi: 10.1016/j.jacc.2012.06.017. Epub 2012 Aug 1.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Oczekiwany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 718016
- CAAE 32767514.0.0000.5413 (Inny identyfikator: Plataforna Brasil)
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .