Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Optimized 2D-RT for Prostate Cancer

12 marca 2018 zaktualizowane przez: Alessio Giuseppe Morganti, IRCCS Azienda Ospedaliero-Universitaria di Bologna

Definition of Fields Margins for Optimized 2D Radiotherapy of Prostate Carcinoma

Prostate cancer (CAP) is one of the most common malignancies in men, both in Western countries and developing countries. Radiation therapy (RT) is an important therapeutic option. New technologies (3D, IMRT, IGRT, VMAT) have been introduced in the last decades, with a progressive improvement of clinical outcome. However, in many countries the only treatment option is the traditional 2D technique based on standard simulation. The indications for field definition in this treatment are still based on expert's opinions. The aim of this analysis is to propose new indications for 2D fields definition based on three-dimensional simulation in a population of patients with CAP. Twenty patients with CAP consecutively treated with RT in our center were identified. Patients underwent CT-simulation in supine position. Pelvic MRI images were fused with CT-simulation images. In this way, delineation of the prostate and seminal vesicles was performed on MRI images. Clinical Target Volume definition (CTV) was performed according to EORTC guidelines simulating 4 different categories: low-risk CAP, intermediate-risk CAP, high-risk CAP without involvement of the seminal vesicles, and high-risk CAP with involvement of seminal vesicles. The Planning Target Volume (PTV) was defined by adding a margin of 10 mm to the CTV in all directions. For each patient, 8 treatment plans were calculated. In particular, for each of the 4 categories of risk, 2 treatment plans were calculated by using a cobalt source or 10 MV photons. Treatment plans were calculated using the box technique. Progressive optimization was realized with an iterative procedure by evaluating the three-dimensional dose distribution. Once the final plan was achieved (respecting the PTV constraint: D98 > 95%), distances of the fields edges from a set of reference points were measured.

Przegląd badań

Status

Zakończony

Warunki

Interwencja / Leczenie

Typ studiów

Interwencyjne

Zapisy (Rzeczywisty)

20

Faza

  • Nie dotyczy

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat do 79 lat (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Męski

Opis

Inclusion Criteria:

  • > 18 years
  • clinical T stage: cT2b, cT2c, cT3a, cT3b
  • informed consent
  • MRI of the pelvis

Exclusion Criteria:

  • > 79 years
  • prior surgery treatment for prostate cancer
  • prior pelvic radiotherapy
  • genetic syndromes of hyper-radio-sensitivity
  • chronic infiammatory bowel disease

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Nie dotyczy
  • Model interwencyjny: Zadanie dla jednej grupy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: 2D radiotherapy
Patients with prostate cancer were treated with 2D-radiotherapy

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
new indications for 2D fields definition
Ramy czasowe: through study completion, up to 10 months
Twenty patients with prostate cancer (CAP) were identified. Pelvic MRI images were fused with CT-simulation images to delineate prostate and seminal vesicles on MRI images. Clinical Target Volume definition (CTV) was performed according to EORTC guidelines simulating 4 different categories: low-risk CAP, intermediate-risk CAP, high-risk CAP with or without involvement of the seminal vesicles. The Planning Target Volume (PTV) was defined by adding a margin of 10 mm to the CTV. For each patient, 8 treatment plans were calculated using box tecnhique: 2 treatment plans for each risk category were calculated by using a cobalt source or 10 MV photons. Progressive optimization was realized with an iterative procedure by evaluating the three-dimensional dose distribution. Once the final plan was achieved (respecting the PTV constraint: D98 > 95%), distances of the fields edges from a set of reference points were measured.
through study completion, up to 10 months

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Dyrektor Studium: Alessio G Morganti, MD, Radiation Oncology Center, Department of Experimental, Diagnostic and Speciality Medicine-DIMES, Unversity of Bologna, S. Orsola-Malpighi Hospital, Bologna, Italy

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

2 lutego 2015

Zakończenie podstawowe (Rzeczywisty)

18 grudnia 2015

Ukończenie studiów (Rzeczywisty)

18 grudnia 2015

Daty rejestracji na studia

Pierwszy przesłany

3 listopada 2017

Pierwszy przesłany, który spełnia kryteria kontroli jakości

9 listopada 2017

Pierwszy wysłany (Rzeczywisty)

13 listopada 2017

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

13 marca 2018

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

12 marca 2018

Ostatnia weryfikacja

1 marca 2018

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Badania kliniczne na Rak prostaty

Badania kliniczne na 2D radiotherapy

3