Optimized 2D-RT for Prostate Cancer
12. März 2018 aktualisiert von: Alessio Giuseppe Morganti, IRCCS Azienda Ospedaliero-Universitaria di Bologna
Definition of Fields Margins for Optimized 2D Radiotherapy of Prostate Carcinoma
Prostate cancer (CAP) is one of the most common malignancies in men, both in Western countries and developing countries.
Radiation therapy (RT) is an important therapeutic option.
New technologies (3D, IMRT, IGRT, VMAT) have been introduced in the last decades, with a progressive improvement of clinical outcome.
However, in many countries the only treatment option is the traditional 2D technique based on standard simulation.
The indications for field definition in this treatment are still based on expert's opinions.
The aim of this analysis is to propose new indications for 2D fields definition based on three-dimensional simulation in a population of patients with CAP.
Twenty patients with CAP consecutively treated with RT in our center were identified.
Patients underwent CT-simulation in supine position.
Pelvic MRI images were fused with CT-simulation images.
In this way, delineation of the prostate and seminal vesicles was performed on MRI images.
Clinical Target Volume definition (CTV) was performed according to EORTC guidelines simulating 4 different categories: low-risk CAP, intermediate-risk CAP, high-risk CAP without involvement of the seminal vesicles, and high-risk CAP with involvement of seminal vesicles.
The Planning Target Volume (PTV) was defined by adding a margin of 10 mm to the CTV in all directions.
For each patient, 8 treatment plans were calculated.
In particular, for each of the 4 categories of risk, 2 treatment plans were calculated by using a cobalt source or 10 MV photons.
Treatment plans were calculated using the box technique.
Progressive optimization was realized with an iterative procedure by evaluating the three-dimensional dose distribution.
Once the final plan was achieved (respecting the PTV constraint: D98 > 95%), distances of the fields edges from a set of reference points were measured.
Studienübersicht
Studientyp
Interventionell
Einschreibung (Tatsächlich)
20
Phase
- Unzutreffend
Teilnahmekriterien
Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.
Zulassungskriterien
Studienberechtigtes Alter
18 Jahre bis 79 Jahre (Erwachsene, Älterer Erwachsener)
Akzeptiert gesunde Freiwillige
Nein
Studienberechtigte Geschlechter
Männlich
Beschreibung
Inclusion Criteria:
- > 18 years
- clinical T stage: cT2b, cT2c, cT3a, cT3b
- informed consent
- MRI of the pelvis
Exclusion Criteria:
- > 79 years
- prior surgery treatment for prostate cancer
- prior pelvic radiotherapy
- genetic syndromes of hyper-radio-sensitivity
- chronic infiammatory bowel disease
Studienplan
Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: N / A
- Interventionsmodell: Einzelgruppenzuweisung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: 2D radiotherapy
Patients with prostate cancer were treated with 2D-radiotherapy
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
new indications for 2D fields definition
Zeitfenster: through study completion, up to 10 months
|
Twenty patients with prostate cancer (CAP) were identified.
Pelvic MRI images were fused with CT-simulation images to delineate prostate and seminal vesicles on MRI images.
Clinical Target Volume definition (CTV) was performed according to EORTC guidelines simulating 4 different categories: low-risk CAP, intermediate-risk CAP, high-risk CAP with or without involvement of the seminal vesicles.
The Planning Target Volume (PTV) was defined by adding a margin of 10 mm to the CTV.
For each patient, 8 treatment plans were calculated using box tecnhique: 2 treatment plans for each risk category were calculated by using a cobalt source or 10 MV photons.
Progressive optimization was realized with an iterative procedure by evaluating the three-dimensional dose distribution.
Once the final plan was achieved (respecting the PTV constraint: D98 > 95%), distances of the fields edges from a set of reference points were measured.
|
through study completion, up to 10 months
|
Mitarbeiter und Ermittler
Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.
Ermittler
- Studienleiter: Alessio G Morganti, MD, Radiation Oncology Center, Department of Experimental, Diagnostic and Speciality Medicine-DIMES, Unversity of Bologna, S. Orsola-Malpighi Hospital, Bologna, Italy
Studienaufzeichnungsdaten
Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.
Haupttermine studieren
Studienbeginn (Tatsächlich)
2. Februar 2015
Primärer Abschluss (Tatsächlich)
18. Dezember 2015
Studienabschluss (Tatsächlich)
18. Dezember 2015
Studienanmeldedaten
Zuerst eingereicht
3. November 2017
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
9. November 2017
Zuerst gepostet (Tatsächlich)
13. November 2017
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
13. März 2018
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
12. März 2018
Zuletzt verifiziert
1. März 2018
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- 2D-RT in prostate cancer
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
NEIN
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Nein
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Nein
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur 2D radiotherapy
-
Oklahoma State UniversityEunice Kennedy Shriver National Institute of Child Health and Human Development...Abgeschlossen
-
Oklahoma State UniversityEunice Kennedy Shriver National Institute of Child Health and Human Development...ZurückgezogenGesundVereinigte Staaten
-
Oklahoma State UniversityEunice Kennedy Shriver National Institute of Child Health and Human Development...Abgeschlossen
-
Ottawa Hospital Research InstituteBeendetPankreaskarzinom Nicht resezierbarKanada
-
Unity Health TorontoAbgeschlossenVorzeitige Wehen | Fetale Glukokortikoid-Exposition
-
Istanbul Medipol University HospitalAbgeschlossenZerebralparese | Motorik | Gangstörungen, neurologisch | Kognitive OrientierungTruthahn
-
Miguel Ayala LeónUnbekanntCOVID-19 | Bluthochdruck, Lungen | Echokardiographie, StressMexiko
-
Miguel Ayala LeónLeiden University Medical Center; Institute of Security and Social Services...UnbekanntEchokardiographie | Schwangerschaftsbedingte Erkrankungen, nicht näher bezeichnet, erstes Trimester | Schwangerschaftsbedingte Erkrankungen, nicht näher bezeichnet, zweites Trimester | Schwangerschaftsbedingte Erkrankungen, nicht näher bezeichnet, drittes Trimester | Ventrikel-UmbauMexiko
-
Ospedale Centrale BolzanoChinese University of Hong Kong; Wolfson Medical Center; Harvard University; University... und andere MitarbeiterNoch keine RekrutierungLungenkrebs | Lunge; Knoten
-
Fujifilm Medical Systems USA, Inc.Abgeschlossen