Portable Ultrasound for Interventional Procedures

24 grudnia 2020 zaktualizowane przez: Ralph Weissleder, MD, Massachusetts General Hospital
We are evaluating whether a portable ultrasound can be safely and effectively used in portable interventional procedures, whether the image quality can be improved to meet standard existing ultrasounds. In the COVID-19 pandemic, transferring patients with COVID-19 to the procedure room results in contamination and shut down of those rooms while also putting folks in transit at some degree of transmission risk. The ability to do procedures at bedside can alleviate those risks greatly.

Przegląd badań

Szczegółowy opis

Portable ultrasound-guided procedures, including paracentesis, thoracentesis, drain placement, or simple biopsies can be required for patients who are difficult to move, in particular COVID-19 patients, patients in the ICU, or on the floor. Portable ultrasounds have demonstrated a convenient ability to provide a point of care ultrasound diagnostic testing with expanding use in standard clinical care. A number of portable ultrasound systems are in routine clinical use at MGH and have been used for diagnostic procedures (e.g. Butterfly, Hologic, others). Most of the systems are still tethered (transducer is connected via cables to a computer or power) which may represent challenges for contamination, especially in interventional procedures. The Healcerion system is the first FDA approved wireless and battery-operated portable ultrasound system of its kind and is in routine use for diagnostic ultrasounds throughout the world.

The goal of the current study is to compare the utility and practical operations of the advanced Healcerion SONON ultrasound system to a standard wheeled and bulky ultrasound systems in current use (Hitachi, GE). While the Healcerion device has been used at other institutions, it has not been used for interventional procedures at MGH. A comparative efficacy study will allow the investigators to examine the safety and efficacy of the device to complete procedures in a portable setting as well as explore whether images can be improved to reach the more robust imaging capability of wired devices.

Typ studiów

Obserwacyjny

Zapisy (Oczekiwany)

200

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Kopia zapasowa kontaktu do badania

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat do 120 lat (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Metoda próbkowania

Próbka prawdopodobieństwa

Badana populacja

Adult patients undergoing an ultrasound-guided procedure, such as paracentesis, thoracentesis, or biopsy

Opis

Inclusion Criteria:

  • The subject has read, signed, and dated the Informed Consent Form (ICF), having been advised of the risks and benefits of the trial in a language understood by the subject.
  • Age ≥ 18 years at the date of informed consent form signature and having the ability to comply with the protocol.
  • Undergoing a clinically indicated ultrasound-guided procedure, such as paracentesis, thoracentesis, or biopsy.

Exclusion Criteria:

  • Patient or health care proxy does not consent
  • Patient not undergoing an ultrasound-guided procedure.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Kohorty i interwencje

Grupa / Kohorta
Interwencja / Leczenie
Adult patients undergoing an ultrasound-guided procedure
Adult patients undergoing an ultrasound-guided procedure, such as paracentesis, thoracentesis, or biopsy
Single-arm, open-label device efficacy study to enroll 200 patients who have been ordered to have an ultrasound-guided procedure by the MGH Interventional Radiology department, including paracentesis, thoracentesis, biopsy, or ultrasound-guided drain placement. Patients will be restricted to adults who can consent.
The FDA approved Healcerion SONON portable ultrasound (linear and curved) will be used during clinically indicated standard ultrasound-guided procedures following clinical standard of care. A standard clinical ultrasound will subsequently be used for image guidance as the gold standard. Images will be compared and improved. The efficacy of the portable ultrasound will be monitored by the clinical user and any complications within 30 days will be determined by chart review.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Efficacy > 80%
Ramy czasowe: Approximately 3 years
Efficacy as defined by the operator in successfully completing the procedure using the portable ultrasound. Reported % of cases the portable ultrasound successfully completed the procedure, stratified by procedure type.
Approximately 3 years

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Oczekiwany)

1 stycznia 2021

Zakończenie podstawowe (Oczekiwany)

31 grudnia 2023

Ukończenie studiów (Oczekiwany)

31 grudnia 2023

Daty rejestracji na studia

Pierwszy przesłany

22 grudnia 2020

Pierwszy przesłany, który spełnia kryteria kontroli jakości

24 grudnia 2020

Pierwszy wysłany (Rzeczywisty)

28 grudnia 2020

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

28 grudnia 2020

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

24 grudnia 2020

Ostatnia weryfikacja

1 grudnia 2020

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • 2020P003984

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Tak

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Badania kliniczne na Terapia ultradźwiękami; Komplikacje

Badania kliniczne na Ultrasound guided procedure