Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Portable Ultrasound for Interventional Procedures

24 dicembre 2020 aggiornato da: Ralph Weissleder, MD, Massachusetts General Hospital
We are evaluating whether a portable ultrasound can be safely and effectively used in portable interventional procedures, whether the image quality can be improved to meet standard existing ultrasounds. In the COVID-19 pandemic, transferring patients with COVID-19 to the procedure room results in contamination and shut down of those rooms while also putting folks in transit at some degree of transmission risk. The ability to do procedures at bedside can alleviate those risks greatly.

Panoramica dello studio

Descrizione dettagliata

Portable ultrasound-guided procedures, including paracentesis, thoracentesis, drain placement, or simple biopsies can be required for patients who are difficult to move, in particular COVID-19 patients, patients in the ICU, or on the floor. Portable ultrasounds have demonstrated a convenient ability to provide a point of care ultrasound diagnostic testing with expanding use in standard clinical care. A number of portable ultrasound systems are in routine clinical use at MGH and have been used for diagnostic procedures (e.g. Butterfly, Hologic, others). Most of the systems are still tethered (transducer is connected via cables to a computer or power) which may represent challenges for contamination, especially in interventional procedures. The Healcerion system is the first FDA approved wireless and battery-operated portable ultrasound system of its kind and is in routine use for diagnostic ultrasounds throughout the world.

The goal of the current study is to compare the utility and practical operations of the advanced Healcerion SONON ultrasound system to a standard wheeled and bulky ultrasound systems in current use (Hitachi, GE). While the Healcerion device has been used at other institutions, it has not been used for interventional procedures at MGH. A comparative efficacy study will allow the investigators to examine the safety and efficacy of the device to complete procedures in a portable setting as well as explore whether images can be improved to reach the more robust imaging capability of wired devices.

Tipo di studio

Osservativo

Iscrizione (Anticipato)

200

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 120 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione di probabilità

Popolazione di studio

Adult patients undergoing an ultrasound-guided procedure, such as paracentesis, thoracentesis, or biopsy

Descrizione

Inclusion Criteria:

  • The subject has read, signed, and dated the Informed Consent Form (ICF), having been advised of the risks and benefits of the trial in a language understood by the subject.
  • Age ≥ 18 years at the date of informed consent form signature and having the ability to comply with the protocol.
  • Undergoing a clinically indicated ultrasound-guided procedure, such as paracentesis, thoracentesis, or biopsy.

Exclusion Criteria:

  • Patient or health care proxy does not consent
  • Patient not undergoing an ultrasound-guided procedure.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Coorti e interventi

Gruppo / Coorte
Intervento / Trattamento
Adult patients undergoing an ultrasound-guided procedure
Adult patients undergoing an ultrasound-guided procedure, such as paracentesis, thoracentesis, or biopsy
Single-arm, open-label device efficacy study to enroll 200 patients who have been ordered to have an ultrasound-guided procedure by the MGH Interventional Radiology department, including paracentesis, thoracentesis, biopsy, or ultrasound-guided drain placement. Patients will be restricted to adults who can consent.
The FDA approved Healcerion SONON portable ultrasound (linear and curved) will be used during clinically indicated standard ultrasound-guided procedures following clinical standard of care. A standard clinical ultrasound will subsequently be used for image guidance as the gold standard. Images will be compared and improved. The efficacy of the portable ultrasound will be monitored by the clinical user and any complications within 30 days will be determined by chart review.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Efficacy > 80%
Lasso di tempo: Approximately 3 years
Efficacy as defined by the operator in successfully completing the procedure using the portable ultrasound. Reported % of cases the portable ultrasound successfully completed the procedure, stratified by procedure type.
Approximately 3 years

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Anticipato)

1 gennaio 2021

Completamento primario (Anticipato)

31 dicembre 2023

Completamento dello studio (Anticipato)

31 dicembre 2023

Date di iscrizione allo studio

Primo inviato

22 dicembre 2020

Primo inviato che soddisfa i criteri di controllo qualità

24 dicembre 2020

Primo Inserito (Effettivo)

28 dicembre 2020

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

28 dicembre 2020

Ultimo aggiornamento inviato che soddisfa i criteri QC

24 dicembre 2020

Ultimo verificato

1 dicembre 2020

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • 2020P003984

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Ultrasuonoterapia; Complicazioni

Prove cliniche su Ultrasound guided procedure

Sottoscrivi