- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07814079
Targeted Ablation to Isolate Scar Channels Causing Ventricular Tachycardia
Segmental Substrate Isolation for the Treatment of Ventricular Tachycardia in Patients With Structural Heart Disease
The goal of this study is to map conducting channels within scar that cause ventricular tachycardia (VT) in patients with scar in their hearts in order to block these channels from causing VT with targeted radiofrequency ablation (cautery).
Participants undergoing VT ablation mapping of these channels by pacing many sites within the scar area and determining where these channels exit the scar into normal tissue. These exits will be ablated. Immediate success and success at 1 year will be evaluated.
Przegląd badań
Status
Interwencja / Leczenie
Szczegółowy opis
Typ studiów
Zapisy (Szacowany)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
New York
-
Valhalla, New York, Stany Zjednoczone, 10595
- Rekrutacyjny
- Westchester Medical Center
-
Pod-śledczy:
- Daniel Frenkel, MD
-
Kontakt:
- Jason T Jacobson, MD
- Numer telefonu: 9144935314
- E-mail: Jason.Jacobson@wmchealth.org
-
Kontakt:
- Sei Iwai, MD
- Numer telefonu: 9149096900
- E-mail: Sei.Iwai@wmchealth.org
-
Główny śledczy:
- Jason Jacobson, MD
-
Pod-śledczy:
- Sei Iwai, MD
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Patients with structural heart disease undergoing VT ablation
Exclusion Criteria:
- Unable or unwilling to sign consent
- Cardiogenic shock or NYHA Class IV heart failure and not a candidate for mechanical circulatory support for the procedure (percutaneous left ventricular assist device (LVAD), extracorporeal membrane oxygenation, or implanted LVAD)
- Absence of substrate during initial voltage mapping
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Number of participants achieving substrate Isolation with ablation of exit sites
Ramy czasowe: Perioperative/Periprocedural: This will be measured at the end of the study ablation procedure only.
|
Inability to stimulate the ventricle (physiologic parameter) while pacing in the substrate area contained by the ablation lines through each pacemap exit, at sites that were able to stimulate the ventricle prior to ablation.
This will be manifest by the absence of a QRS complex resultant from the pacing stimulus.
This is a
|
Perioperative/Periprocedural: This will be measured at the end of the study ablation procedure only.
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
VT invasive map exit and vMap exit match
Ramy czasowe: Perioperative/Periprocedural: This will be measured throughout the study ablation procedure.
|
Percent matching of VT exits determined by activation/entrainment/pace mapping for matched ECG morphologies with vMap determined exits
|
Perioperative/Periprocedural: This will be measured throughout the study ablation procedure.
|
|
Channel exit and vMap match
Ramy czasowe: Perioperative/Periprocedural: This will be measured throughout the study ablation procedure.
|
Percent matching of noninvasively mapped exit sites compared with invasively mapped channel exits
|
Perioperative/Periprocedural: This will be measured throughout the study ablation procedure.
|
|
Inducibility post initial ablation
Ramy czasowe: Perioperative/Periprocedural: This will be measured during the study ablation procedure, after the first set of radiofrequency lesions is placed based in initial mapping.
|
VT inducibility after first lesion sets determined by channel mapping
|
Perioperative/Periprocedural: This will be measured during the study ablation procedure, after the first set of radiofrequency lesions is placed based in initial mapping.
|
|
1 year outcome
Ramy czasowe: 1 year: This will be measured for each subject up to 1 year after the study procedure.
|
VT recurrence at 1 year determined by therapies delivered by implantable cardioverted defibrillator and presentation with sustained VT below ICD detection.
|
1 year: This will be measured for each subject up to 1 year after the study procedure.
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 23989
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .