- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT01375855
Late Incomplete Stent Apposition Evaluation II: Comparison Between Polimer-based and No-polimer Stent System. IVUS Based Study (LISAII)
Late Incomplete Stent Apposition Evaluation II: Vascular Effects Evaluation After Polimer and No-polimer Based Coronary Artery Drug Eluting Stent Ilmplantation. An IVUS Based Study
Vascular effects evaluation after non-polimeric and polimeric paclitaxel stent implantation.In particular the investigators will use Taxus )as a polimeric stent)and Axxion (as a non-polimeirc)stent system. The investigators will look at late stent malapposition by means of intracoronary ultrasound imaging technique (IVUS) at baseline and 9 months follow-up. The investigators sought to compare the two stent types with the same drug to verify the polimer role. The polimer itself seems to provoke inflammation and hypersensibility if the arterial wall and it seems to be the base of a process of positive remodeling found at drug eluting stent implantation site.
This positive remodeling is the mechanism producing late stent malapposition which on its turn can determine stent thrombosis, as demonstrated by pathological studies. At the same time the investigators will study the incidence of clinical events like myocardial infarction, stent thrombosis, TLR and death along with the incidence of angiographic restenosis at 2 years follow up.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Tipo de estudo
Inscrição (Antecipado)
Estágio
- Fase 4
Contactos e Locais
Locais de estudo
-
-
-
Barcelona, Espanha, 08025
- Recrutamento
- Hospital de La Santa Creu Y Sant Pau
-
Investigador principal:
- Manel Sabate, MD, PhD
-
Contato:
- Manel sabate, MD, PhD
- Número de telefone: 0034935565851
- E-mail: msabatet@santpau.es
-
Contato:
- Clarissa Cola, MD
- Número de telefone: 0034935565851
- E-mail: clarissacola@gmail.com
-
Subinvestigador:
- Victoria Martin Yuste, MD
-
Subinvestigador:
- Clarissa Cola, MD
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Patients with coronary artery stenosis in one, two or three vessels, and with objective evidence of isquemia.
- The stenosis must allow IVUS analisis, must be treatable with angioplasty with stent
- Target Vessel diameter must be between 2.25- 4 mm with QCA.
- Patients must sign informed consent
- Patients and their physician must accept the angiographic follow-up
Exclusion Criteria:
- 18 years old patients
- SCA within the last 72 hours, or patients with CK twice over the upper normal limit
- Pregnancy
- Target vessel diameter < 2.25 or > 4 mm by QCA
- Previous brakitherapy or DES in the target lesion
- Restenotic lesion
- -Allergy to aspirin, clopidogrel or ticlopidin
- Patients enrolled in other studies or trials
- By-pass graft lesions
- Real bifurcationa lesions
- Severe Renal insufficiency (creatinin clearance < 30 ml/min).
- Severe Liver failure(GOT y GPT > 3 times the upper normal limit)
- Life expectancy < 1 year because of other pathologies
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Comparador Ativo: Polimeric-PES
Arm receiving polimeric stent (Taxus)
|
Coronary artery stent implantation
|
|
Comparador Ativo: Non-Polimeric PES
Arm receiving non-polimeric PES (axxion)
|
Coronary artery stent implantation
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Prazo |
|---|---|
|
Intra coronary ultrasound analysis to verify stent malapposition at follow-up
Prazo: 9 months
|
9 months
|
Medidas de resultados secundários
Medida de resultado |
Prazo |
|---|---|
|
Clinical events (myocardial infarction, TLR,at 1, 9, 12, 24 months follow-up:; Incidence of restenosis with QCA at 9 months follow-up Intimal hiperplasia measured by IVUS at 9 months follow-up; Stent Thrombosis.
Prazo: 9 months and 2 years
|
9 months and 2 years
|
Colaboradores e Investigadores
Investigadores
- Investigador principal: Manel Sabate, MD, PhD, Hospital de la Santa Creu Y Sant Pau, Unidad de Hemodinamica
Publicações e links úteis
Publicações Gerais
- Hong MK, Mintz GS, Lee CW, Park DW, Lee SW, Kim YH, Kang DH, Cheong SS, Song JK, Kim JJ, Park SW, Park SJ. Impact of late drug-eluting stent malapposition on 3-year clinical events. J Am Coll Cardiol. 2007 Oct 9;50(15):1515-6. doi: 10.1016/j.jacc.2007.07.038. Epub 2007 Aug 27. No abstract available.
- Shiratori Y, Cola C, Brugaletta S, Alvarez-Contreras L, Martin-Yuste V, del Blanco BG, Ruiz-Salmeron R, Diaz J, Pinar E, Marti V, Garcia-Picart J, Sabate M. Randomized comparison between polymer-free versus polymer-based paclitaxel-eluting stent: two-year final clinical results. Circ Cardiovasc Interv. 2014 Jun;7(3):312-21. doi: 10.1161/CIRCINTERVENTIONS.113.000800. Epub 2014 May 6.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 2007-000142-12
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .