- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07628231
Assessment of Sevoflurane Consumption During General Anesthesia With a Low Fresh Gas Flow Rate of 0.3 L/Min (FGF 03)
Driven by industry demands and the need for anesthesia that consumes fewer resources ("green anesthesia"), manufacturers of anesthesia ventilators have developed closed-circuit ventilators. In a closed-circuit system, during the exhalation phase, gases are not released outside the ventilator into the atmosphere but are injected into the inspiratory limb of the circuit after being warmed and having CO2 removed. It is a closed loop. However, the loop is not completely closed because a very small stream of air is additionally injected into the inspiratory limb to limit the risk of hypoxia. This small stream of air is called "Fresh Gas Flow" or FGF.
To optimize this closed-loop recirculation, manufacturers have designed machines capable of minimizing the fresh gas flow. In the 2000s, machines operated with FGFs of 2 L/min, dropping to flows as low as 0.5 L/min by 2010. This low-flow regime allows for an 80% reduction in halogenated gas (sevoflurane) consumption while maintaining the same efficiency. Recently, even more sophisticated machines have been designed with FGFs of 0.3 L/min. Some of these new machines will be commercially available on a large scale in 2026. As part of an industrial partnership, the Nîmes University Hospital has validated the post-CE marking of these machines for certain manufacturers (including General Electric); the post-CE marking allows the manufacturer to have access to usage data Given that this product has only recently been introduced to the market, very little data has been published on the use of sevoflurane in daily practice at very low FGF flow rates (0.3 to 0.5 L/min).
For the past four months, the Nîmes University Hospital has had two CE-marked machines (GE, CS 850) capable of ventilating at flow rates of 0.3 L/min. These machines are connected to software (Carestation Insight) that allows all anonymized ventilator data to be recorded independently of the users. This software has been in continuous use in 12 operating rooms since 2024 within our institution and has been the subject of numerous publications (see Ref. 19). All ventilation and sevoflurane data are continuously recorded and stored in a secure, anonymous cloud (Ref. 19).
The objective of this retrospective study is to analyze the database of sevoflurane consumption derived from the Carestation Insight software for patients who underwent general anesthesia with ventilation at FGF flow rates of 0.3 L/min and to compare these data with our database of patients under anesthesia at flow rates of 0.5 to 2 L/min, also derived from this same cloud.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Tipo de estudo
Inscrição (Estimado)
Contactos e Locais
Contato de estudo
- Nome: Philippe CUVILLON, PU-PH
- Número de telefone: + 33 4.66.68.30.50
- E-mail: philippe.cuvillon@chu-nimes.fr
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
Adult patients undergoing surgery under general anesthesia with mechanical ventilation
- Connected to a ventilator linked to the Carestaion software
- No refusal as indicated by a letter of consent
Exclusion Criteria:
- Refusal to participate
- Minor patients
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
FGF flow rates of 0.3
Patients who underwent general anesthesia with mechanical ventilation at a minute ventilation of 0.3
|
None, Pure observatinal study
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
sevoflurane consumption
Prazo: Perioperative
|
Measurement of sevoflurane consumption (in liters) per minute of anesthesia
|
Perioperative
|
|
FGF
Prazo: Perioperative
|
Measurement of gas flow rate (FGF) (L/minute).
|
Perioperative
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Diretor de estudo: Anissa MEGZARI, Centre Hospitalier Universitaire de Nīmes
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
- Local/2026/PC-01
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .