Placenta accreta spectrum (PAS) is a life-threatening obstetric disorder involving abnormal placental invasion into the uterine wall, which is associated with severe maternal and neonatal complications. Despite advances in imaging, prenatal diagnosis remains challenging due to variability in ultrasound interpretation and reliance on operator expertise.
This study will establish a standardized ultrasound video acquisition protocol and develop a deep learning-based model using Vision Transformer (ViT) architecture to process dynamic ultrasound sequences. The model will be trained using clinically confirmed postpartum outcomes as reference labels.
The diagnostic performance of the system will be systematically evaluated, with the goal of improving consistency in interpretation and supporting more efficient clinical decision-making in prenatal PAS screening.
Tipo de estudo
Inscrição (Estimado)
Contactos e Locais
Contato de estudo
- Nome: Fang He, M.D, PhD
- Número de telefone: +86 13724831279
- E-mail: Gzhefang@gzhmu.edu.cn
Locais de estudo
-
-
Guangdong
-
Guangzhou, Guangdong, China, 510150
- Recrutamento
- The Third Affiliated Hospital, Guangzhou Medical University
-
Contato:
- Fang He, MD, PhD
- Número de telefone: +86 13724831279
- E-mail: Gzhefang@gzhmu.edu.cn
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
Descrição
Inclusion criteria:
- Pregnant women aged between 18 and 45 years;
- Gestational age between 24 and 34 weeks;
- Pregnant women with a history of placenta previa;
- Pregnant women with an anterior placenta;
- Willingness to participate in the study and provision of written informed consent.
Exclusion criteria:
- Failure to provide written informed consent;
- Presence of severe complications that precluded continuation of pregnancy;
- Inability to comply with study procedures for other reasons.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Diagnostic performance of the end-to-end Vision Transformer (ViT)-based ultrasound AI model for placenta accreta spectrum (PAS)
Prazo: At delivery (following confirmation of PAS status by surgical and/or pathological findings)
|
Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristic curve (AUC) of the model.
|
At delivery (following confirmation of PAS status by surgical and/or pathological findings)
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Clinical Feasibility of the Standardized Ultrasound Video Recording Method
Prazo: At enrollment during the ultrasound examination
|
Completion Rate (Proportion of patients who successfully complete the standardized recording) and time consumption (Mean recording time)
|
At enrollment during the ultrasound examination
|
|
Consistency and Efficiency Between the AI Model and Physician Diagnosis
Prazo: At enrollment during the ultrasound examination
|
Diagnostic Consistency: Kappa coefficient used to evaluate the consistency between the AI model's diagnoses and those of experienced ultrasound physicians (Kappa > 0.75 indicates good agreement).
|
At enrollment during the ultrasound examination
|
|
Safety of the AI Model
Prazo: At delivery, when PAS status and maternal outcomes are assessed
|
False Negative Rate: Proportion of missed PAS-positive patients and the impact on patient outcomes .
|
At delivery, when PAS status and maternal outcomes are assessed
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- Ethics Review NO. 286A01
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .