- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07676929
Clinical Evaluation of 3D-Printed Versus Semi-Direct Composite Resin Restorations
Visão geral do estudo
Status
Intervenção / Tratamento
Descrição detalhada
Dental restorations are commonly used to restore teeth affected by caries or structural defects. Advances in digital dentistry have introduced three-dimensional (3D) printing technologies that enable the fabrication of indirect composite resin restorations with improved precision, efficiency, and reproducibility. Semi-direct composite resin restorations represent another conservative restorative approach that combines the advantages of direct and indirect techniques while reducing polymerization shrinkage and improving anatomical form.
Although both techniques are increasingly used in clinical practice, evidence regarding their long-term clinical performance remains limited. Therefore, this randomized controlled clinical trial aims to compare the clinical performance of 3D-printed composite resin restorations and semi-direct composite resin restorations in posterior teeth requiring Class II inlay or onlay restorations.
Sixty patients aged 25 to 40 years who require two Class II inlay or onlay restorations will be enrolled by invitation from patients attending the Faculty of Dentistry, Tanta University. Participants will be randomly allocated into two groups according to the restorative material and fabrication technique used. Group I will receive 3D-printed composite resin restorations, while Group II will receive semi-direct composite resin restorations.
All cavity preparations and restorative procedures will be performed according to standardized clinical protocols and manufacturers' instructions. Clinical evaluations will be conducted at baseline, 6 months, 9 months, and 12 months after restoration placement using the modified FDI World Dental Federation criteria.
The primary objective is to evaluate the overall clinical performance and survival of the restorations over a 12-month follow-up period. Secondary outcomes include assessment of retention, marginal integrity, surface roughness, anatomical form, postoperative sensitivity, and the occurrence of secondary caries.
The findings of this study will contribute to the evidence regarding the effectiveness and clinical reliability of 3D-printed composite resin restorations compared with semi-direct composite resin restorations and may support clinical decision-making in restorative dentistry.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Tanta
-
Tanta, Tanta, Egito, 31527
- Restorative Department, Faculty of Dentistry, Tanta University
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- Patients aged 25-40 years.
- Patients requiring two Class II inlay or onlay restorations.
- Teeth with carious lesions or defective restorations requiring indirect restorative treatment.
- Teeth with sufficient structure to receive an inlay/onlay restoration.
Exclusion Criteria:
- Patients with systemic diseases or medical conditions that may affect oral health or healing.
- Pregnant or lactating patients.
- Patients with poor oral hygiene or uncontrolled periodontal disease.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Dobro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: 3D-Printed Composite Resin Restorations
Participants will receive Class II inlay or onlay restorations fabricated using 3D-printed composite resin.
Restorations will be placed following standardized cavity preparation and manufacturer instructions.
Clinical performance will be evaluated at baseline, 6, 9, and 12 months using modified FDI criteria
|
Fabrication and placement of Class II inlay or onlay restorations using 3D-printed composite resin material.
|
|
Experimental: Semi-Direct Composite Resin Restorations
Participants will receive Class II inlay or onlay restorations fabricated using the semi-direct composite resin technique.
Restorations will be placed following standardized cavity preparation and manufacturer instructions.
Clinical performance will be evaluated at baseline, 6, 9, and 12 months using modified FDI criteria
|
Fabrication and placement of Class II inlay or onlay restorations using the semi-direct composite resin technique
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Fracture of restorations
Prazo: 12 months
|
Clinical evaluation of restoration fracture or bulk failure after placement of 3D-printed composite resin and semi-direct composite resin restorations.
at baseline, 6 months, 9 months, and 12 months after restoration placement.
using a modified FDI criteria score.
All restorations will be evaluated and categorized based on their clinical performance according to the assigned criteria: score 1 indicates a clinically excellent restoration, scores 2 and 3 represent clinically acceptable restorations, while scores 4 and 5 are considered clinically unacceptable.
Clinical success will be defined as restorations receiving scores of 1, 2, or 3, whereas scores of 4 or 5 will be considered clinical failures.
|
12 months
|
Colaboradores e Investigadores
Patrocinador
Publicações e links úteis
Publicações Gerais
- Nguyen-Thi TL, Tran TM, Tran-Thi HP, Nguyen-Ho PM, Do TT, Dang MH. Effect of preparation design on the fracture behavior of 3D-printed restorations in an in-vitro tooth wear model. BMC Oral Health. 2026 Mar 12;26(1):704. doi: 10.1186/s12903-026-08031-0.
- Tribst JPM, Veerman A, Pereira GKR, Kleverlaan CJ, Dal Piva AMO. Comparative Strength Study of Indirect Permanent Restorations: 3D-Printed, Milled, and Conventional Dental Composites. Clin Pract. 2024 Sep 20;14(5):1940-1952. doi: 10.3390/clinpract14050154.
- Kaffaf MB, Sesen P, Tokac SO. Comparison of the intaglio surface accuracy of occlusal veneers fabricated using two different techniques to restore severe occlusal tooth wear: An in vitro study. J Prosthet Dent. 2026 Jun;135(6):e97-e105. doi: 10.1016/j.prosdent.2025.12.027. Epub 2026 Jan 6.
- Peskersoy C, Acar G. In Vitro Evaluation of the Mechanical Properties of Posterior Adhesive Restorations Fabricated Using Three Different Techniques. Polymers (Basel). 2025 May 14;17(10):1340. doi: 10.3390/polym17101340.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- 3D-Printed Composite
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .