- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07682974
Effect of WRAD Lens on Axial Growth and Refraction in Low-hyperopic Chinese Children
26 de junho de 2026 atualizado por: He Eye Hospital
Myopia is one of the most common visual impairments worldwide.This not only poses long-term risks to individual health but also imposes significant medical and economic burdens on society.
[6] Therefore, delaying the onset of myopia and effectively controlling its progression has become an urgent issue that needs to be addressed.In recent years, a new type of highly aspherical lenslet (HAL) has been proposed.
Its optical design includes a refractive correction area in the central region and a peripheral annular area.
This annular area can form a "myopic defocus zone", increasing the myopic defocus signal around the retina.
Studies have confirmed that this design can effectively slow down the progression of myopia in already myopic children.
However, it is currently unclear whether this lens has a preventive effect on children who are not yet myopic but have a risk of developing myopia.
Visão geral do estudo
Status
Ainda não está recrutando
Condições
Tipo de estudo
Intervencional
Inscrição (Estimado)
117
Estágio
- Não aplicável
Contactos e Locais
Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.
Contato de estudo
- Nome: Guanghao Qin
- Número de telefone: +8618842664420
- E-mail: qinguanghao2020@163.com
Critérios de participação
Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.
Critérios de elegibilidade
Idades elegíveis para estudo
- Filho
Aceita Voluntários Saudáveis
Sim
Descrição
Inclusion Criteria:
- Children aged 6 to 9 with low hyperopia, regardless of gender
- The refractive error is between 0 and 2.00D
- The best corrected visual acuity of both eyes is ≥ 0.10 LogMAR
- The subjects themselves and their guardians voluntarily participated
Exclusion Criteria:
- Systemic diseases or eye diseases
- Received myopia control treatment through medication or optical
- Any situation where participation is deemed unsuitable by the investigator
Plano de estudo
Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Prevenção
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Group A
Participants will be wearing with-the-rule astigmatic defocus lens glasses.
The lens was prescribed with 0.00 diopters.
It is recommended to wear it for ≥ 10 hours per day
|
The lens was prescribed with 0.00 diopters
|
|
Experimental: Group B
Participants will be wearing with-the-rule astigmatic defocus lens glasses (non-plano defocus spectacles); the central optical zone degree completely correct their baseline under cycloplegia refractive errors.
It is recommended to wear it for ≥ 10 hours per day
|
The magnitude of the central optical zone completely corrected their refractive errors under baseline cycloplegia
|
|
Comparador de Placebo: Group C (control group)
Participants will be wearing traditional single vision lens, lens has no correction function.
It is recommended to wear it for ≥ 10 hours per day
|
The lenses do not have corrective functions
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Changes in the axial length
Prazo: baseline, 6-month, 12-month, 18-month, 24-month
|
The changes in axial length of the eyes in the experimental group and the control group in the first and second years
|
baseline, 6-month, 12-month, 18-month, 24-month
|
|
Change in the spherical equivalent
Prazo: Baseline, 6-month, 12-month, 18-month, 24-month
|
The changes in spherical equivalent in the experimental group and the control group in the first and second years
|
Baseline, 6-month, 12-month, 18-month, 24-month
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Changes in axial length
Prazo: Baseline, 6-month, 12-month, 18-month, 24-month
|
Changes in axial length from baseline to year 1 and year 2 in the plano defocus and non-plano defocus experimental groups.
|
Baseline, 6-month, 12-month, 18-month, 24-month
|
|
Change in equivalent spherical
Prazo: Baseline, 6-month, 12-month, 18-month, 24-month
|
Changes in spherical equivalent refraction from baseline to year 1 and year 2 in the plano defocus and non-plano defocus experimental groups.
|
Baseline, 6-month, 12-month, 18-month, 24-month
|
Colaboradores e Investigadores
É aqui que você encontrará pessoas e organizações envolvidas com este estudo.
Patrocinador
Colaboradores
Datas de registro do estudo
Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.
Datas Principais do Estudo
Início do estudo (Estimado)
1 de julho de 2026
Conclusão Primária (Estimado)
1 de dezembro de 2029
Conclusão do estudo (Estimado)
1 de julho de 2030
Datas de inscrição no estudo
Enviado pela primeira vez
26 de junho de 2026
Enviado pela primeira vez que atendeu aos critérios de CQ
26 de junho de 2026
Primeira postagem (Real)
6 de julho de 2026
Atualizações de registro de estudo
Última Atualização Postada (Real)
6 de julho de 2026
Última atualização enviada que atendeu aos critérios de controle de qualidade
26 de junho de 2026
Última verificação
1 de junho de 2026
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
- Doenças oculares
- Erros de refração
- Astigmatismo
- Fenômenos fisiológicos musculoesqueléticos e neurais
- Fenômenos fisiológicos celulares
- Fenômenos bioquímicos
- Fenômenos químicos
- Fenômenos fisiológicos do sistema nervoso
- Fenômenos fisiológicos oculares
- Sensação
- Transdução de Sinal
- Transdução de Sinal Luminoso
- Visão, Ocular
Outros números de identificação do estudo
- WRAD2026
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
NÃO
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Não
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Não
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .