Comparative AAPOS Validation of the Birefringent Amblyopia Screener with Isolated Small-Angle Strabismus

Robert W Arnold, Robert W Arnold

Abstract

Background: The Rebion blinq binocular birefringent ocular alignment screener was recently commercially released, but it did not yet have validation by American Association for Pediatric Ophthalmology and Strabismus (AAPOS) uniform guidelines.

Methods: Children and adults from a high-risk eye practice had screening by blinq with validation by AAPOS 2003 guidelines. Then, the blinq was compared to the Adaptica 2WIN with CR corneal reflex strabismus estimation by AAPOS 2003 guidelines plus additional efforts to identify patients with diminished binocularity.

Results: Blinq in 100 patients compared to 2003 AAPOS amblyopia risk factors (ARF) had sensitivity 67%, specificity 75% and PPV of 82%. Both blinq and 2WIN were completed by 87 patients median age 6.5 years. Sensitivity, specificity and positive predictive value (PPV) for blinq were 75%, 68% and 81% whereas 2WIN had 91%, 68% and 84%. The blinq referred two young patients with isolated, small-angle strabismic amblyopia that 2WIN refractive function passed.

Conclusion: Despite its non-refractive design to identify binocular foveation, blinq performed well with refractive and strabismic uniform risk factors and a PPV greater than 80%.

Clinical trials registry: NCT04195711.

Keywords: amblyopia; amblyopia risk factor; birefringent; fixation instability; photoscreening; strabismus.

Conflict of interest statement

Dr. Arnold is a board member and President of PDI Check that developed a vision screening game for the Nintendo 3DS and Glacier Medical Software that markets ROP Check cloud-based NICU monitoring software. Dr. Arnold coordinates the Alaska Blind Child Discovery which has received discounted instruments from several vendors. Dr. Arnold is an investigator and protocol developer for the Pediatric Eye Disease Investigator Group. Dr Arnold has a patent PDI Check pending to Robert Arnold and Alex Damarjian. The author reports no other conflicts of interest in this work.

© 2020 Arnold.

Figures

https://www.ncbi.nlm.nih.gov/pmc/articles/instance/6999781/bin/OPTH-14-325-g0001.jpg

References

    1. Hunter DG, Shah AS, Sau S, Nassif D, Guyton DL. Automated detection of ocular alignment with binocular retinal birefringence scanning. Appl Opt. 2003;42:3047–3053. doi:10.1364/AO.42.003047
    1. Gramatikov BI, Irsch K, Wu YK, Guyton DL. New pediatric vision screener, part II: electronics, software, signal processing and validation. Biomed Eng Online. 2016;15:15. doi:10.1186/s12938-016-0128-7
    1. Jost RM, Yanni SE, Beauchamp CL, et al. Beyond screening for risk factors: objective detection of strabismus and amblyopia. JAMA Ophthalmol. 2014;132:814–820. doi:10.1001/jamaophthalmol.2014.424
    1. Arnold SL, Arnold AW, Sprano JH, Arnold RW. Performance of the 2WIN photoscreener with “CR” strabismus estimation in high risk patients. Am J Ophthalmol. 2019;207:195–203. doi:10.1016/j.ajo.2019.04.016
    1. Donahue SP, Arthur B, Neely DE, Arnold RW, Silbert D, Ruben JB. Guidelines for automated preschool vision screening: a 10-year, evidence-based update. J AAPOS. 2013;17:4–8. doi:10.1016/j.jaapos.2012.09.012
    1. Donahue S, Arnold R, Ruben JB. Preschool vision screening: what should we be detecting and how should we report it? Uniform guidelines for reporting results from studies of preschool vision screening. J AAPOS. 2003;7:314–316. doi:10.1016/S1091-8531(03)00182-4
    1. Smith KA, Arnold AW, Sprano JH, Arnold SL, Arnold RW. Performance of a quick screening version of the nintendo 3DS PDI check game in patients with ocular suppression. J Pediatr Ophthalmol Strabismus. 2019;56:234–237. doi:10.3928/01913913-20190502-01
    1. Kelly KR, Cheng-Patel CS, Jost RM, Wang YZ, Birch EE. Fixation instability during binocular viewing in anisometropic and strabismic children. Exp Eye Res. 2019;183:29–37. doi:10.1016/j.exer.2018.07.013
    1. Birch EE, Subramanian V, Weakley DR. Fixation instability in anisometropic children with reduced stereopsis. J AAPOS. 2013;17:287–290. doi:10.1016/j.jaapos.2013.03.011
    1. Arnold RW. Amblyopia risk factor prevalence. J Pediatr Ophthalmol Strabismus. 2013;50:213–217. doi:10.3928/01913913-20130326-01
    1. Donahue SP, Baker CN, Committee on P, et al. Procedures for the evaluation of the visual system by pediatricians. Pediatrics. 137;2016:1–9. doi:10.1542/peds.2015-3597
    1. Shah SS, Jimenez JJ, Rozema E, Nguyen MK, Fong DS, Mehta AM. Validation of the Pediatric Vision Scanner in a Normal Preschool Population (Poster PO358). San Francisco, CA: American Academy of Ophthalmology; 2019.