Successful removal of large intraocular foreign body by 25-gauge microincision vitrectomy surgery

Hiroshi Kunikata, Megumi Uematsu, Toru Nakazawa, Nobuo Fuse, Hiroshi Kunikata, Megumi Uematsu, Toru Nakazawa, Nobuo Fuse

Abstract

We describe a new technique for removing a large intraocular foreign body by 25-gauge microincision vitrectomy surgery (25G-MIVS). Noncomparative interventional case series were performed at a single centre. Two patients with a long smooth intraocular vitreal foreign body underwent phacoemulsification and aspiration, intraocular lens implantation, 25G-MIVS, and extraction of the foreign body. The foreign body was removed through a posterior capsulorhexis, anterior continuous curvilinear capsulorhexis, and a corneal incision. In both cases, the foreign body was safely removed through the corneal incision, and IOL was implanted and well positioned. The surgical incision did not require suturing. No postoperative complications associated with this technique were found. The corneal endothelial cell density was maintained over 2000 cells/mm(2) in both cases during recent follow-up examinations. Our findings indicate that 25G-MIVS with this technique can be used to extract a long slender smooth foreign body. It is safe, without complications, and can be performed without enlarging the 25-gauge sclerotomy.

Figures

Figure 1
Figure 1
Preoperative slit-lamp photographs, preoperative fundus photograph, preoperative computed tomographic image, and intraoperative photographs of intraocular foreign body (Case 1; (a, b, c), Case 2; (d, e, f)). (a) Preoperative slit-lamp photograph shows a slight penetrating wound in the iris and lens at the 9 o'clock position and a posterior subcapsular cataract at the same position. (b) Fundus photograph showing vitreous haemorrhage and retinal tear with subretinal haemorrhage located on the temporal side of the macula. Computed tomographic image showing a large foreign body. (c) Intraoperative fundus showing a large metallic intraocular foreign body anterior to the retina. (d) External photograph showing the penetrating wound at the 4 o'clock position and the corneal wound was closed by corneal sutures during the initial surgery. (e) Slit-lamp photograph showing that the posterior subcapsular cataract has progressed. (f) Intraoperative fundus photograph showing large glass intraocular foreign body anterior to the retina.
Figure 2
Figure 2
Intraoperative photographs and postoperative slit-lamp photographs of Case 1 (a, b, c) and Case 2 (d, e, f). (a) and (b) Metallic foreign body extracted through an anterior and posterior capsulorhexis, and corneal incision (triple C-through technique). (c) Slit-lamp photograph (inverted image as seen by the surgeon) 1 day postoperatively showing no need of suturing, no subconjunctival haemorrhage, and well-positioned intraocular lens. (d) and (e) Glass foreign body extracted through an anterior and posterior capsulorhexis, and corneal incision (triple C-through technique). (f) Slit-lamp photograph (inverted image as seen by the surgeon) 1 day postoperatively showing no need of suturing, except the original penetration wound, no subconjunctival haemorrhage and well-positioned intraocular lens.

References

    1. Fujii GY, De Juan E, Jr., Humayun MS, et al. Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery. Ophthalmology. 2002;109(10):1814–1820.
    1. Fujii GY, De Juan E, Jr., Humayun MS, et al. A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery. Ophthalmology. 2002;109(10):1807–1812.
    1. Mura M, Tan SH, De Smet MD. Use of 25-gauge vitrectomy in the management of primary rhegmatogenous retinal detachment. Retina. 2009;29(9):1299–1304.
    1. Kunikata H, Nishida K. Visual outcome and complications of 25-gauge vitrectomy for rhegmatogenous retinal detachment; 84 consecutive cases. Eye. 2010;24(6):1071–1077.
    1. Kadonosono K, Yamakawa T, Uchio E, Yanagi Y, Tamaki Y, Araie M. Comparison of visual function after epiretinal membrane removal by 20-gauge and 25-gauge vitrectomy. American Journal of Ophthalmology. 2006;142(3):513–515.
    1. Kellner L, Wimpissinger B, Stolba U, Brannath W, Binder S. 25-gauge vs 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial. British Journal of Ophthalmology. 2007;91(7):945–948.
    1. Tsang CW, Cheung BT, Lam RF, et al. Primary 23-gauge transconjunctival sutureless vitrectomy for rhegmatogenous retinal detachment. Retina. 2008;28(8):1075–1081.
    1. Mahapatra SK, Rao NG. Visual outcome of pars plana vitrectomy with intraocular foreign body removal through sclerocorneal tunnel and sulcus-fixated intraocular lens implantation as a single procedure, in cases of metallic intraocular foreign body with traumatic cataract. Indian Journal of Ophthalmology. 2010;58(2):115–118.
    1. Kiss S, Vavvas D. 25-gauge transconjunctival sutureless pars plana vitrectomy for the removal of retained lens fragments and intraocular foreign bodies. Retina. 2008;28(9):1346–1351.

Source: PubMed

3
Se inscrever