Awake microlaparoscopy with the Insuflow device

Oscar D Almeida Jr, Oscar D Almeida Jr

Abstract

Background and objectives: Patients undergoing laparoscopy often complain of shoulder pain, shivering, or both following laparoscopy. An increase in awake microlaparoscopic procedures has been reported. The objective of this study was to investigate the usefulness of heating and humidifying the carbon dioxide gas for the pneumoperitoneum with the Insuflow device (Lexion Medical, St. Paul, Minnesota) during awake microlaparoscopic procedures.

Methods: Awake microlaparoscopy was performed with the Insuflow device for heating and humidifying the carbon dioxide for the pneumoperitoneum.

Results: The incidence of transient shoulder pain in the Insuflow group was 5% compared with 40% in the dry carbon dioxide group. No patient in the Insuflow group complained of shivering, whereas 55% in the control group had shivering. Fogging of the microlaparoscope lens was decreased in the Insuflow group.

Conclusions: Heating and humidifying the carbon dioxide gas produced fewer patient complaints of shoulder pain and shivering and decreased fogging of the microlaparoscope lens compared with procedures done with dry carbon dioxide during awake microlaparoscopic procedures.

References

    1. Almeida OD., Jr. Microlaparoscopic equipment. In: Almeida OD., Jr ed. Microlaparoscopy. New York: John Wiley & Sons Inc; 2000:11–18
    1. Almeida OD, Jr, Val-Gallas JM. Appendectomy under local anesthesia following conscious pain mapping with microlaparoscopy. Hum Reprod. 1998;13(3):588–590
    1. Almeida OD, Jr, Val-Gallas JM. Conscious pain mapping. J Am Assoc Gynecol Laparosc. 1997;4:587–590
    1. Almeida OD, Jr, Val-Gallas JM. Office microlaparoscopy under local anesthesia in the diagnosis and treatment of chronic pelvic pain. J Am Assoc Gynecol Laparosc. 1998;5(4):407–410
    1. Almeida OD, Jr, Rizk B. Microlaparoscopic ovarian drilling under local anesthesia. Mid East Fertil Soc J. 1998;3(2):189–191
    1. Almeida OD., Jr Microlaparoscopic conscious pain mapping in the evaluation of chronic pelvic pain: A case report. JSLS. 2002;6:81–83
    1. Jacobs VR, Morrison JE, Mettler L, Mundhenke C, Jonat W. Measurement of C02 hypothermia during laparoscopy and pelviscopy: How cold it gets and how to prevent it. J Am Assoc Gynecol Laparosc. 1999;6(3):289–295
    1. Ott DE, Reich H, Love B, et al. Reduction of laparoscopy-induced hypothermia, postoperative pain and recovery room length of stay by pre-conditioning gas with the Insuflow® device: A prospective randomized controlled multi-center study. JSLS. 1998;2:321–329
    1. Garner RE, Wright EB, Ott DE. Maintenance of cell viability at laparoscopy by hydration of C02. J Am Assoc Gynecol Laparosc. 2000;7(3):S19
    1. Gray R, Ott D, Henderson AC, Cochran SA, Roth EA. Severe local hypothermia from laparoscopic gas evaporative jet cooling: A mechanism to explain clinical observations. JSLS. 1999;3:171–177
    1. Almeida OD, Jr, Val-Gallas JM, Browning J. A protocol for conscious sedation in microlaparoscopy. J Am Assoc Gynecol Laparosc. 1997;4:591–594
    1. Jacobs VR, Morrison JE, Mundhenke C, Golombeck K, Jonat W, Hander D. Model to determine resistance and leakage-dependent flow on flow performance of laparoscopic insulators to predict gas flow rate of cannulas. J Am Assoc Gynecol Laparosc. 2000;7(3):331–337
    1. Demco L. The effect of heating and humidifying gas on patients undergoing awake laparoscopy. J Am Assoc Gynecol Laparosc. 2000;7(3):S11
    1. Almeida OD., Jr. Current state of office laparoscopic surgery. J Am Assoc Gynecol Laparosc. 2000;7(4):545–546

Source: PubMed

3
Se inscrever