Clinical and radiological evaluation of Trabecular Metal and the Smith-Robinson technique in anterior cervical fusion for degenerative disease: a prospective, randomized, controlled study with 2-year follow-up

Håkan Löfgren, M Engquist, P Hoffmann, B Sigstedt, L Vavruch, Håkan Löfgren, M Engquist, P Hoffmann, B Sigstedt, L Vavruch

Abstract

A prospective, randomized, controlled study was carried out to compare the radiological and clinical outcomes after anterior cervical decompression and fusion (ACDF) with Trabecular Metal (TM) to the traditional Smith-Robinson (SR) procedure with autograft. The clinical results of cervical fusion with autograft from the iliac crest are typically satisfactory, but implications from the donor site are frequently reported. Alternative materials for cervical body interfusion have shown lower fusion rates. Trabecular Metal is a porous tantalum biomaterial with structure and mechanical properties similar to that of trabecular bone and with proven osteoconductivity. As much as 80 consecutive patients planned for ACDF were randomized for fusion with either TM or tricortical autograft from the iliac crest (SR) after discectomy and decompression. Digitized plain radiographic images of 78 (98%) patients were obtained preoperatively and at 2-year follow-up and were subsequently evaluated by two senior radiologists. Fusion/non-fusion was classified by visual evaluation of the A-P and lateral views in forced flexion/extension of the cervical spine and by measuring the mobility between the fused vertebrae. MRI of 20 TM cases at 2 years was successfully used to assess the decompression of the neural structures, but was not helpful in determining fusion/non-fusion. Pain intensity in the neck, arms and pelvis/hip were rated by patients on a visual analog scale (VAS) and neck function was rated using the Neck Disability Index (NDI) the day before surgery and 4, 12 and 24 months postoperatively. Follow-ups at 12 and 24 months were performed by an unbiased observer, when patients also assessed their global outcome. Fusion rate in the SR group was 92%, and in the TM group 69% (P < 0.05). The accuracy of the measurements was calculated to be 2.4 degrees . Operating time was shorter for fusion with TM compared with autograft; mean times were 100 min (SD 18) and 123 min (SD 23), respectively (P = 0.001). The patients' global assessments of their neck and arm symptoms 2 years postoperatively for the TM group were rated as 79% much better or better after fusion with TM and 75% using autograft. Pain scores and NDI scores were significantly improved in both groups when compared with baseline at all follow-ups, except for neck pain at 1 year for the TM group. There was no statistically significant difference in clinical outcomes between fusion techniques or between patients who appeared radiologically fused or non-fused. There was no difference in pelvic/hip pain between patients operated on with or without autograft. In our study, Trabecular Metal showed a lower fusion rate than the Smith-Robinson technique with autograft after single-level anterior cervical fusion without plating. There was no difference in clinical outcomes between the groups. The operative time was shorter with Trabecular Metal implants.

Figures

Fig. 1
Fig. 1
Trabecular MetalTM implant
Fig. 2
Fig. 2
Flowchart for the study
Fig. 3
Fig. 3
Clearly fused (group I) after surgery with autograft (SR)
Fig. 4
Fig. 4
Clearly fused (group I) after surgery with Trabecular Metal (TM)
Fig. 5
Fig. 5
Clearly non-fused (group III) after surgery with Trabecular Metal (TM). Note the radiolucent zone above the implant. Mobility is seen between images in flexion and extension
Fig. 6
Fig. 6
Pain rating (VAS) and Neck Disability Index preoperatively and at the follow-ups. The box plots illustrate the 25th and 75th percentiles with the median value marked in between. The range is shown by whiskers, but extreme outliers are separately shown by circles. There were no statistically significant differences between the surgical methods

References

    1. Banwart JC, Asher MA, Hassanein RS. Iliac crest bone graft harvest donor site morbidity: a statistical evaluation. Spine. 1995;20:1055–1060. doi: 10.1097/00007632-199505000-00012.
    1. Barbour SA, King W. Basic science update: the safe and effective use of allograft tissue, an update. Am J Sports Med. 2003;31:791–797.
    1. Baskin DS, Traynelis V (2004) Failure of porous tantalum cervical interbody fusion devices: two-year results from a prospective, randomized, multi-center, clinical study. Annual Meeting, Cervical Spine Research Society, Boston, USA
    1. Bobyn JD, Stackpool GJ, Hacking SA, Tanzer M, Krygier JJ. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg (Br) 1999;81-B:907–914. doi: 10.1302/0301-620X.81B5.9283.
    1. Boden SD, Schimandle JH (1996) Fusion: biology of lumbar spine fusion and bone graft materials. In: International Society for Study of the Lumbar Spine Editorial Committee, editors. The lumbar spine, 2nd edn, Saunders, Philadelphia, pp 1284–1306
    1. Bucci MN, Philyaw D. Successful fusion using allogeneic bone graft in anterior cervical discectomy and fusion. J S C Med Assoc. 1998;94:9–11.
    1. Buck BE, Malinen TI, Brown MD. Bone transplantation and the human immunodeficiency virus: an estimate of the risk of acquired immunodeficiency syndrome (AIDS) Clin Orthop Relat Res. 1989;240:129–136.
    1. Cannada LK, Scherping SC, Yoo JU, Jones PK, Emery SE. Pseudoarthrosis of the cervical spine: a comparison of radiographic diagnostic measures. Spine. 2003;28:46–51. doi: 10.1097/00007632-200301010-00012.
    1. Cauthen JC, Kinard RE, Vogler JB, Jackson DE, DePaz OB, Hunter OL, et al. Outcome analysis of noninstrumented anterior cervical discectomy and interbody fusion in 348 patients. Spine. 1998;23:188–192. doi: 10.1097/00007632-199801150-00008.
    1. Cloward RB. The anterior approach for ruptured cervical discs. J Neurosurg. 1958;15:602–614. doi: 10.3171/jns.1958.15.6.0602.
    1. Cohen R. A porous tantalum Trabecular Metal: basic science. Am J Orthop. 2002;31:216–217.
    1. DePalma AF, Rothman RH, Lewinnek GE, Canale ST. Anterior interbody fusion for severe cervical disc degeneration. Surg Gynecol Obstet. 1972;134:755–758.
    1. Fassett DR, Apfelbaum RI, Hipp JA. Comparison of fusion assessment techniques: computer-assisted versus manual measurements. J Neurosurg Spine. 2008;8:544–547. doi: 10.3171/SPI/2008/8/6/544.
    1. Fernández-Fairen M, Sala P, Dufoo M, Jr, Ballester J, Murcia A, Merzthal L. Anterior cervical fusion with tantalum implant: a prospective randomized controlled study. Spine. 2008;33:465–472. doi: 10.1097/BRS.0b013e3181657f49.
    1. Fujibayashi S, Neo M, Nakamura T. Stand-alone interbody cage versus anterior cervical plate for treatment of cervical disc herniation: sequential changes in cage subsidence. J Clin Neurosci. 2008;15:1017–1022. doi: 10.1016/j.jocn.2007.05.011.
    1. Gazdag AR, Lane JM, Glaser D, Fortster RA. Alternatives to autologous bone graft. Efficacy and indications. J Am Acad Orthop Surg. 1995;3:1–8.
    1. Kärrholm J. Roentgen stereophotogrammetry: review of orthopaedic applications. Acta Orthop Scand. 1989;60:491–503. doi: 10.3109/17453678909149328.
    1. Kelly DJ, Ahmad M, Brull SJ. Preemptive analgesia. I. Physiological pathways and pharmacological modalities. Can J Anaesth. 2001;48:1000–1010. doi: 10.1007/BF03016591.
    1. Lavand’homme P. Perioperative pain. Curr Opin Anaesthesiol. 2006;19:556–561. doi: 10.1097/01.aco.0000245284.53152.1f.
    1. Leivseth G, Kolstad F, Nygaard OP, Zoëga B, Frobin W, Brinckmann P. Comparing precision of distortion-compensated and stereophotogrammetric Roentgen analysis when monitoring fusion in the cervical spine. Eur Spine J. 2006;15:774–779. doi: 10.1007/s00586-005-0929-z.
    1. Levi AD, Choi WG, Keller PJ, Heiserman JE, Sonntag VK, Dickman CA. The radiographic and imaging characteristics of porous tantalum implants within the human cervical spine. Spine. 1998;23:1245–1251. doi: 10.1097/00007632-199806010-00014.
    1. Levine BR, Sporer S, Poggie RA, Della Valle CJ, Jacobs JJ. Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials. 2006;27:4671–4681. doi: 10.1016/j.biomaterials.2006.04.041.
    1. Lind BI, Zoëga B, Rosen H. Autograft versus interbody fusion cage without plate fixation in the cervical spine: a randomized clinical study using radiostereometry. Eur Spine J. 2007;16:1251–1256. doi: 10.1007/s00586-007-0337-7.
    1. Löfgren H, Vallö Christiansen J, Johannsson V, Levander B. MRI and clinical course after anterior cervical decompression and fusion: a prospective two-year longitudinal evaluation showing fibrous union of the bovine graft. Neuro-Orthopedics. 1999;26:19–31.
    1. Löfgren H, Johannsson V, Olsson T, Ryd L, Levander B. Rigid fusion after Cloward operation for cervical disc disease using autograft, allograft, or xenograft: a randomized study with radiostereometric and clinical follow-up assessment. Spine. 2000;25:1908–1916. doi: 10.1097/00007632-200008010-00008.
    1. Mroz TE, Joyce MJ, Steinmetz MP, Lieberman IH, Wang JC. Musculoskeletal allograft risks and recalls in the United States. J Am Acad Orthop Surg. 2008;16:559–565.
    1. Peolsson A, Vavruch L, Hedlund R. Long-term randomised comparison between a carbon fibre cage and the Cloward procedure in the cervical spine. Eur Spine J. 2007;16:173–178. doi: 10.1007/s00586-006-0067-2.
    1. Pollock R, Alcelik I, Bhatia C, Chuter G, Lingutla K, Budithi C, Krishna M. Donor site morbidity following iliac crest bone harvesting for cervical fusion: a comparison between minimally invasive and open techniques. Eur Spine J. 2008;17:845–852. doi: 10.1007/s00586-008-0648-3.
    1. Ryd L, Yuan X, Löfgren H. Methods for determining the accuracy of radiostereometric analysis (RSA) Acta Orthop Scand. 2000;71:403–408. doi: 10.1080/000164700317393420.
    1. Ryu SI, Mitchell M, Kim DH. A prospective randomized study comparing a cervical carbon fiber cage to the Smith–Robinson technique with allograft and plating: up to 24 months follow-up. Eur Spine J. 2006;15:157–164. doi: 10.1007/s00586-005-0951-1.
    1. Samartzis D, Shen FH, Lyon C, Phillips M, Goldberg EJ, An HS. Does rigid instrumentation increase the fusion rate in one-level anterior cervical discectomy and fusion? Spine J. 2004;4:636–643. doi: 10.1016/j.spinee.2004.04.010.
    1. Sampath P, Bendebba M, Davis JD, Ducker T. Outcome in patients with cervical radiculopathy: prospective, multicenter study with independent clinical review. Spine. 1999;24:591–597. doi: 10.1097/00007632-199903150-00021.
    1. Savolainen S, Usenius JP, Hernesniemi J. Iliac crest versus artificial bone grafts in 250 cervical fusions. Acta Neurochir (Wien) 1994;129:54–57. doi: 10.1007/BF01400873.
    1. Schnee CL, Freese A, Weil RJ, Marcotte PJ. Analysis of harvest morbidity and radiographic outcome using autograft for anterior cervical fusion. Spine. 1997;22:2222–2226. doi: 10.1097/00007632-199710010-00005.
    1. Schoettle T, Standard S, Lanford G, Abram S, Robertson D, Robie B (2005) Successful use of a modern porous tantalum (Trabecular MetalTM) device for cervical interbody fusion: results from a prospective, randomized multi-centre clinical trial. Annual Meeting, Cervical Spine Research Society, San Diego, USA
    1. Shimamoto N, Cunningham BW, Dmitriev AE, Minami A, McAfee PC. Biomechanical evaluation of stand-alone interbody fusion cages in the cervical spine. Spine. 2001;26:E432–E436. doi: 10.1097/00007632-200110010-00008.
    1. Silber JS, Anderson DG, Daffner SD, Brislin BT, Leland JM, Hilibrand AS, Vaccaro AR, Albert TA. Donor site morbidity after anterior iliac crest bone harvest for single-level anterior cervical discectomy and fusion. Spine. 2003;28:134–139. doi: 10.1097/00007632-200301150-00008.
    1. Singh K, Samartzis D, Strom J, Manning D, Campbell-Hupp M, Wetzel FT, Gupta P, Phillips FM. A prospective, randomized, double-blind study evaluating the efficacy of postoperative continuous local anesthetic infusion at the iliac crest bone graft site after spinal arthrodesis. Spine. 2005;30:2477–2483. doi: 10.1097/01.brs.0000186323.11285.b1.
    1. Singh K, Phillips FM, Kuo E, Campbell M. A prospective, randomized, double-blind study of the efficacy of postoperative continuous local anesthetic infusion at the iliac crest bone graft site after posterior spinal arthrodesis: a minimum of 4-year follow-up. Spine. 2007;32:2790–2796. doi: 10.1097/BRS.0b013e31815b7650.
    1. Smith GW, Robinson RA. The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg (Am) 1958;41A:607–624.
    1. Svensson E. Ordinal invariant measures for individual and group changes in ordered categorical data. Stat Med. 1998;17:2923–2936. doi: 10.1002/(SICI)1097-0258(19981230)17:24<2923::AID-SIM104>;2-#.
    1. Svensson E. Guidelines to statistical evaluation of data from ratings scales and questionnaires. J Rehabil Med. 2001;33:47–48. doi: 10.1080/165019701300006542.
    1. Vaccaro AR, Chiba K, Heller JG, TCh Patel, Thalgott JS, Truumees E, Fischgrund JS, Craig MR, Berta SC, Wang JC, North American Spine Society for Contemporary Concepts in Spine Care Bone grafting alternatives in spinal surgery. Spine J. 2002;2:206–215. doi: 10.1016/S1529-9430(02)00180-8.
    1. Van Limbeek J, Jacobs WCH, Anderson PG, Pavlov PW. A systematic literature review to identify the best method for a single-level anterior cervical interbody fusion. Eur Spine J. 2000;9:129–136. doi: 10.1007/s005860050223.
    1. Vavruch L, Hedlund R, Javid D, Leszniewski W, Shalabi A. A prospective randomized comparison between the Cloward procedure and a carbon fiber cage in the cervical spine: a clinical and radiologic study. Spine. 2002;27:1694–1701. doi: 10.1097/00007632-200208150-00003.
    1. Vernon H, Mior S. The Neck Disability Index: a study of reliability and validity. J Manipulative Physiol Ther. 1991;14:409–415.
    1. Wang JC, Yu WD, Sandhu HS, Tam V, Delamarter RB. A comparison of magnetic resonance and computed tomographic image quality after the implantation of tantalum and titanium instrumentation. Spine. 1998;23:1684–1688. doi: 10.1097/00007632-199808010-00014.
    1. White AA, 3d, Southwick WO, Deponte RJ, Gainor JW, Hardy R. Relief of pain by anterior cervical spine fusion for spondylosis: a report of sixty-five patients. J Bone Joint Surg Am. 1973;55:525–534.
    1. Wigfield C, Robertson J, Gill S, Nelson R. Clinical experience with porous tantalum interbody implants in a prospective randomized controlled trial. Br J Neurosurg. 2003;17:418–425. doi: 10.1080/02688690310001611206.
    1. Zoëga B (1998) Cervical discectomy and fusion with or without plate fixation: a randomized clinical and radiographic study on outcome and cost-utility. Thesis, Göteborg University, Göteborg, Sweden
    1. Zoëga B, Lind B (2005) A radiostereometric analysis (RSA) of TM cervical device (Hedrocel) in ACDF. Annual Meeting, Cervical Spine Research Society-European section, Rome, Italy
    1. Zoëga B, Karrholm J, Lind B. Outcome scores in degenerative cervical disc surgery. Eur Spine J. 2000;9:137–143. doi: 10.1007/s005860050224.
    1. Zoëga B, Kärrholm J, Lind B. Mobility provocation radiostereometry in anterior cervical spine fusions. Eur Spine J. 2003;12(6):631–636. doi: 10.1007/s00586-001-0362-x.
    1. Zou X, Li H, Teng X, Xue Q, Egund N, Lind M, Bunger C. Pedicle screw fixation enhances anterior lumbar interbody fusion with porous tantalum cages: an experimental study in pigs. Spine. 2005;30:E392–E399. doi: 10.1097/01.brs.0000170588.80377.3f.

Source: PubMed

3
Se inscrever