Morphological and Mechanical Assessment in the Achilles Tendon After Radiofrequency Stimulation in Runners (RFAchillesRun)

14 июня 2026 г. обновлено: Manuel Trinidad-Fernández, University of Malaga

Morphological and Mechanical Changes in the Achilles Tendon After the Application of INDIBA® Therapy in Healthy Runners: A Pre-post Quasi-experimental Study

448 kHz capacitive-resistive monopolar radiofrequency is an emerging physiotherapy technique whose usefulness and clinical relevance still need to be investigated. This study is a pre-post quasi-experimental study in which several variables will be measured before and immediately after 448 kHz capacitive resistive monopolar radiofrequency. It aims to analyze the morphological and mechanical changes in the Achilles tendon following the intervention in healthy runners.

Обзор исследования

Подробное описание

The Achilles tendon is fundamental to running biomechanics, and its performance directly affects athletic performance and injury prevention. 448 kHz capacitive resistive monopolar radiofrequency has demonstrated effects on vascularization, recovery, and elasticity of musculoskeletal tissues. However, there are no studies that comprehensively evaluate the morphological, mechanical, and functional changes in the Achilles tendón in healthy runners after the application of this technique. The investigators expect the intervention to induce short-term morphological and mechanical changes in the Achilles tendon, providing further insight into the potential of this technique as a preventive tool.

Тип исследования

Интервенционный

Регистрация (Оцененный)

19

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Контакты исследования

  • Имя: José Daniel Gómez-Requena, PT
  • Номер телефона: 34 686305704
  • Электронная почта: danielgomezrequena@gmail.com

Места учебы

    • Malaga
      • Vélez-Málaga, Malaga, Испания
        • Clínica Gómez Requena
        • Контакт:

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Взрослый
  • Пожилой взрослый

Принимает здоровых добровольцев

Да

Описание

Inclusion Criteria:

  • Adults aged 18-65
  • Runners with at least one year of regular practice.
  • Must not have suffered any ligament, bone, tendon, or muscle injury in the lower limb or lumbar region during the last year.

Exclusion Criteria:

  • History of lower limb surgery, rheumatic or neuromuscular diseases or pregnancy
  • Contraindication for radiofrecuency treatment.
  • Athletes with visual, auditory, or any other impairment that may affect their cognitive ability to understand the test.

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Исследования в области здравоохранения
  • Распределение: Н/Д
  • Интервенционная модель: Одногрупповое задание
  • Маскировка: Нет (открытая этикетка)

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: Radiofrecuency in tendon achilles
Monopolar capacitive-resistive radiofrequency (CRMR) at 448 kHz. Applied with the objective of hyperthermia (thermal effect).
The procedure will consist of a 20-minute radiofrequency session on the Achilles tendon, applying 10 minutes in capacitive mode and 10 minutes in resistive mode. The device has a maximum peak power of 200 W and 450 V. Both modes will be administered as a hyperthermia dose, adjusted according to the patient's subjective perception of heat, with a target of 8/10. The application will be performed longitudinally on the Achilles tendon, from proximal to distal and from distal to proximal, measuring the variables before and after the procedure. In resistive mode, continuous wave will be used, and the return electrode will be a plate placed under the patient's abdomen. The entire procedure will be carried out following the manufacturer's instructions.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Achilles tendon thickness (mm) measured by B-mode ultrasound
Временное ограничение: 1 hour
The Achilles tendon will be assessed with the participant in a prone position, legs extended and feet resting over the edge of the examination couch. Ultrasound images will be acquired using a linear transducer in the long axis of the tendon, at the level of the medial malleolus, in order to reduce bone-related artefacts. B-mode ultrasound will be used for the evaluation.
1 hour
Elastography in Achilles tendon
Временное ограничение: 1 hour
Tendon stiffness and elasticity were assessed using compression elastography. Color-coded elastographic maps and quantitative tissue deformation values were obtained following standardized procedures previously described in the literature. Measurements were performed at the same procedure used for measuring tendon thickness.
1 hour

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Plantar flexion strength
Временное ограничение: 1 hour
It will be assessed using an electronic isometric dynamometer, recording the maximum force generated during a voluntary plantar flexion contraction against fixed resistance, maintaining a standardized ankle position and performing several attempts to obtain a reliable value.
1 hour
Functionality of the lower limb
Временное ограничение: 1 hour
It will be evaluated using the Multijump Rebound Test, a validated test that analyzes the capacity for repeated jumping and the efficiency of the stretch-shortening cycle, allowing the functional changes to be related to the morphological and mechanical properties of the muscle-tendon system.
1 hour

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Оцененный)

1 июля 2026 г.

Первичное завершение (Оцененный)

30 июля 2026 г.

Завершение исследования (Оцененный)

30 июля 2026 г.

Даты регистрации исследования

Первый отправленный

9 июня 2026 г.

Впервые представлено, что соответствует критериям контроля качества

9 июня 2026 г.

Первый опубликованный (Действительный)

15 июня 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

17 июня 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

14 июня 2026 г.

Последняя проверка

1 июня 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Другие идентификационные номера исследования

  • 37-2026-H

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕ РЕШЕНО

Описание плана IPD

Initially, individual participant data are not planned to be shared. However, data sharing may be considered if a formal collaboration agreement is proposed by another research group working on the same topic, provided that the request is scientifically justified and ethically appropriate. In such cases, all necessary protocols and safeguards will be implemented to ensure data anonymisation, confidentiality, and compliance with applicable data protection regulations.

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .