Evaluation of bite force after open reduction and internal fixation using microplates

S Tharani Kumar, Saurabh Saraf, S Prasanna Devi, S Tharani Kumar, Saurabh Saraf, S Prasanna Devi

Abstract

The primary aim of this study is to determine maximum bite force in molar and incisor regions of healthy individuals, to evaluate the bite force after open reduction and internal fixation of mandibular fractures using micro plates, for a period of up to 6 weeks and to determine the rate of recovery of maximum bite force in an Indian population.

Keywords: Bite Force Evaluation; Internal Fixation; Microplates; Open Reduction.

Figures

Fig 1.
Fig 1.
Bite Force Displacement Appliance
Fig 2.
Fig 2.
Load versus Displacement Chart

References

    1. Erickson GM, Van Kirk SD, Su J, Levenston ME, Caler WE, Carter DR. Bite-force estimation for Tyrannosaurus rex from tooth-marked bones. Nature. 1996 Aug;382(22):706–8.
    1. Gerlach KL, Schwarz A. Bite forces in patients after treatment of mandibular angle fractures with miniplate osteosynthesis according to Champy. Int J Oral Maxillofac Surg. 2002 Aug;31(4):345–8.
    1. Howell AH, Brudevold F. Vertical forces used during chewing of food. J Dent. Res. 1950;29(2):133–6.
    1. Ugural AC, Fenster SK. Advanced Strength and Applied Elasticity. 4th edition. Prentice Hall; 2003.
    1. Márton K, Hermann P, Dankó K, Fejérdy P, Madléna M, Nagy G. Evaluation of oral manifestations and masticatory force in patients with polymyositis and dermatomyositis. J Oral Pathol Med. 2005 Mar;34(3):164–9.
    1. Murphy MT, Haug RH, Barber JE. An in vitro comparison of the mechanical characteristics of three sagittal ramus osteotomy fixation techniques. J Oral Maxillofac Surg. 1997 May;55(5):489–94.
    1. Korkmaz HH. Evaluation of different miniplates in fixation of fractured human mandible with the finite element method. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007 Jun;103(6):1–13.
    1. Ellis E, Throckmorton GS. Bite forces after open or closed treatment of mandibular condylar process fractures. Oral Maxillofac Surg. 2001 Apr;59(4):389–95.
    1. Dal Santo F, Ellis E, 3rd, Throckmorton GS. The effects of zygomatic complex fracture on masseteric muscle force. J Oral Maxillofac Surg. 1992 Aug;50(8):791–9.
    1. Regalo SC, Santos CM, Vitti M, Regalo CA, de Vasconcelos PB, Mestriner W, Jr, et al. Evaluation of molar and incisor bite force in indigenous compared with white population in Brazil. Arch Oral Biol. 2008 Mar;53(3):282–6.
    1. Nishigawa K, Bando E, Nakano M. Quantitative study of bite force during sleep associated bruxism. J Oral Rehabil. 2001 May;28(5):485–91.
    1. Hattori Y, Satoh C, Kunieda T, Endoh R, Hisamatsu H, Watanabe M. Bite forces and their resultants during forceful intercuspal clenching in humans. J Biomech. 2009 Jul 22;42(10):1533–8.
    1. Kawai N, Tanaka E, Takata T, Miyauchi M, Tanaka M, Todoh M, et al. Influence of additive hyaluronic acid on the lubricating ability in the temporomandibular joint. J Biomed Mater Res A. 2004 Jul;70(1):149–53.
    1. Haug RH, Morgan JP. A microplate and screw technique for intraoral open reduction of mandibular angle fractures. J Oral Maxillofac Surg. 1995 Feb;53(2):218–9.
    1. Feller KU, Richter G, Schneider M, Eckelt U. Combination of microplate and miniplate for osteosynthesis of mandibular fractures: an experimental study. Int J Oral Maxillofac Surg. 2002 Feb;31(1):78–83.

Source: PubMed

Подписаться