Renal Cortical Elastography: Normal Values and Variations

Harsh Singh, Om Biju Panta, Umesh Khanal, Ram Kumar Ghimire, Harsh Singh, Om Biju Panta, Umesh Khanal, Ram Kumar Ghimire

Abstract

Introduction: Renal cortical elastography has shown conflicting but promising results in evaluation of chronic kidney disease and other renal disorders. The purpose of this study was to establish a normogram of renal cortical elasticity values and assess their variation between right and left kidney and their relation with age, gender, body mass index, renal dimensions and skin to cortex distance.

Methods: The study was a hospital based cross sectional study performed at Tribhuvan University Teaching Hospital, a tertiary care center in Kathmandu, Nepal. All individuals referred for Ultrasound from General Health Check up clinic were included in the study. Patient with abnormal ultrasound findings and abnormal renal function test were excluded from the study. Renal morphometry including length, cortical thickness, and skin to cortex distance were measured in B mode imaging and renal cortical elastography was measured with region of interest box of 1 × 0.5 cm. All analyses were done using Statistical Package for Social Sciences 20.0 soft ware.

Results: A total of 95 individuals who met the inclusion criteria were included in the study. The mean values of right and left renal cortical shear wave velocity were 1.49 ± 0.19 m/s and 1.54 ± 0.19 m/s respectively. Statistical significant difference was observed between the renal cortical shear wave velocity of right and left kidney. The renal shear wave velocity was seen to decrease with age, however the correlation was not statistically significant. No significant difference was also noted in renal shear wave velocity among various sex or Body mass index groups. Statistically significant negative correlation was noted between skin to cortex distance and renal cortical shear wave velocities. However no statistically significant correlation was noted between renal dimensions and renal cortical shear wave velocities.

Conclusions: The normal cortical elasticity values in terms of shear wave velocity of right and left kidney were established. Renal elasticity is independent of the age, gender, Body mass index and renal dimensions.

Keywords: Renal elastography; Shear wave elastography; Ultrasound.

Conflict of interest statement

Conflicts of Interest: None.

Figures

Figure 1
Figure 1
Measurement of renal cortical elasticity. ROI box is seen placed in the renal cortex parallel to the renal pyramids (marked hypoechoic triangular area) and not extending up to the renal sinus (hyperechoic area). The shear wave velocity in m/s is displayed in the lower left corner.
Figure 2
Figure 2
Renal cortical elasticity variation by age group.

References

    1. Lopez-Novoa JM, Rodríguez-Peña AB, Ortiz A, et al. Etiopa-thology of chronic tubular, glomerular and renovascular ne-phropathies: clinical implications. J Transl Med. 2011;9(13):13.
    1. Nankivell BJ, Borrows RJ, Fung CL-S, et al. The natural history of chronic allograft nephropathy. N Engl J Med. 2003;349(24):2326–33.
    1. Moghazi S, Jones E, Schroepple J, et al. Correlation of renal histopathology with sonographic findings. Kidney Int. 2005;67(4):1515–20.
    1. Sugiura T, Nakamori A, Wada A, et al. Evaluation of tubu-lointerstitial injury by Doppler ultrasonography in glomerular diseases. Clin Nephrol. 2004;61(2):119–26.
    1. Rizzo L, Calvaruso V, Cacopardo B, et al. Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatitis C. Am J Gastroenterology. 2011;106(12):2112–20.
    1. Friedrich-Rust M, Wunder K, Kriener S, et al. Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography. Radiology. 2009;252(2):595–604.
    1. Guo LH, Xu HX, Fu HJ, et al. Acoustic radiation force impulse imaging for noninvasive evaluation of renal parenchyma elasticity: preliminary findings. PloS one. 2013;8(7):e68925.
    1. Hu Q, Wang XY, He HG, et al. Acoustic radiation force impulse imaging for non-invasive assessment of renal histopathology in chronic kidney disease. PloS one. 2014;9(12):e115051.
    1. Zheng XZ, Yang B, Fu NH. Preliminary study on the kidney elasticity quantification in patients with chronic kidney disease using virtual touch tissue quantification. Iran J Radiology. 2015;1:12.
    1. Wang L, Xia P, Lv K, et al. Assessment of renal tissue elasticity by acoustic radiation force impulse quantification with histo-pathological correlation: preliminary experience in chronic kidney disease. Eur Radiol. 2014;24(7):1694–9.
    1. Asano K, Ogata A, Tanaka K, et al. Acoustic radiation force impulse elastography of the kidneys Is shear wave velocity affected by tissue fibrosis or renal blood flow? J Ultrasound Med. 2014;33(5):793–801.
    1. Bota S, Bob F, Sporea I, et al. The influence of glomerular filtration rate on kidney stiffness values assessed by acoustic radiation force impulse (ARFI) elastography. Ultraschall der Medizin-European J Ultrasound. 2013;(S 01):34. WS_SL9_01.
    1. Stock K, Klein B, Vo CM, et al. ARFI-based tissue elasticity quantification in comparison to histology for the diagnosis of renal transplant fibrosis. Clin Hemorheol Microcirc. 2009;46(2-3):139–48.
    1. Syversveen T, Brabrand K, Midtvedt K, et al. Assessment of renal allograft fibrosis by acoustic radiation force impulse quantification - a pilot study. Transpl Int. 2011;24(1):100–5.
    1. Bruno C, Caliari G, Zaffanello M, et al. Acoustic radiation force impulse (ARFI) in the evaluation of the renal paren-chymal stiffness in paediatric patients with vesicoureteral reflux: preliminary results. Eur Radiol. 2013;23(12):3477–84.
    1. Sohn B, Kim MJ, Han SW, et al. Shear wave velocity measurements using acoustic radiation force impulse in young children with normal kidneys versus hydronephrotic kidneys. Ultrasonography. 2014;33(2):116.
    1. Clevert D, Stock K, Klein B, et al. Evaluation of acoustic radiation force impulse (ARFI) imaging and contrast-enhanced ultrasound in renal tumors of unknown etiology in comparison to histological findings. Clin Hemorheol Microcirc. 2008;43(1-2):95–107.
    1. Ozkan F, Yavuz YC, Inci MF, et al. Interobserver variability of ultrasound elastography in transplant kidneys: correlations with clinical-Doppler parameters. Ultrasound Med Biol. 2013;39(1):4–9.
    1. Grenier N, Poulain S, Lepreux S, et al. Quantitative elastog-raphy of renal transplants using supersonic shear imaging: a pilot study. Eur Radiol. 2012;22(10):2138–46.
    1. Tang JW, Mason M, Kushner RF, et al. Peer reviewed: South Asian American perspectives on overweight, obesity, and the relationship between weight and health. Prev chronic Dis. 2012:9.
    1. Grenier N, Gennisson JL, Cornelis F, et al. Ultrasound elastography of kidney. Ultrasound Clin. 2013;8(4):551–64.
    1. Grenier N, Gennisson JL, Cornelis F, et al. Renal ultrasound elastography. Diagn Interv Imaging. 2013;94(5):545–50.
    1. Fleiss JL. Reliability of measurement. In: Fleiss JL, editor. The design and analysis of clinical experiments. Toronto: Wiley; 1986. pp. 1–32.
    1. Bob F, Bota S, Sporea I, et al. Kidney shear wave speed values in subjects with and without renal pathology and inter-operator reproducibility of acoustic radiation force impulse elas-tography (ARFI) - preliminary results. PloS one. 2014;9(11):e113761.
    1. Bota S, Bob F, Sporea I, et al. Factors that influence kidney shear wave speed assessed by acoustic radiation force impulse elastography in patients without kidney pathology. Ultrasound Med Biol. 2015;41(1):1–6.
    1. Goertz R, Amann K, Heide R, et al. An abdominal and thyroid status with acoustic radiation force impulse elastometry - a feasibility study: acoustic radiation force impulse elas-tometry of human organs. Eur journal radiology. 2011;80(3):e226–30.
    1. Gallotti A, D'Onofrio M, Mucelli RP. Acoustic radiation force impulse (ARFI) technique in ultrasound with virtual touch tissue quantification of the upper abdomen. La Radiol medica. 2010;115(6):889–97.
    1. Bota S, Bob F, Sporea I, et al. The age influence the kidney stiffness assessed by means of acoustic radiation force impulse (ARFI) elastography? Ultraschall der Medizin-European J Ultrasound. 2013;(S 01):34. WS_SL9_04.
    1. Gennisson JL, Grenier N, Combe C, et al. Supersonic shear wave elastography of in vivo pig kidney: influence of blood pressure, urinary pressure and tissue anisotropy. Ultrasound Med Biol. 2012;38(9):1559–67.
    1. Chade AR. Renal vascular structure and rarefaction. Compr Physiol. 2013;3(2):817–31.
    1. Hughes AD, Bathula R, Park C, et al. Microcirculatory rarefaction in South Asians - a potential mechanism for increased cardiovascular risk and diabetes. PloS one. 2013;10:8.
    1. Nama V, Onwude J, Manyonda I, et al. Is capillary rarefaction an independent risk marker for cardiovascular disease in South Asians? J Hum Hypertens. 2011;25(7):465–6.
    1. Bob F, Bota S, Sporea I, et al. Is Acoustic Radiation Force Impulse (ARFI) elastography a useful method for predicting kidney pathology? Ultraschall der Medizin-European J Ultrasound. 2013;(S 01):34. WS_SL9_06.
    1. Horster S, Mandel P, Zachoval R, et al. Comparing acoustic radiation force impulse imaging to transient elastography to assess liver stiffness in healthy volunteers with and without valsalva manoeuvre. Clin Hemorheol Microcirc. 2009;46(2-3):159–68.

Source: PubMed

Подписаться