DE-CT in Lung Cancer Proton Therapy (DE-CT)
DE-CT vs. SE-CT as Optimal Imaging During Treatment for Adaptive Proton Therapy in Stage III Non Small Cell Lung Cancer (NSCLC)
Studieöversikt
Status
Betingelser
Intervention / Behandling
Detaljerad beskrivning
In order to calculate the dose distribution of protons adequately, accurate estimations of the stopping power ratio (SPR) medium to water, are required. Using a conversion from single energy CT (SE-CT) images results in an uncertainty in the SPR of at least 3-4%. This uncertainty results in in the use of larger margins around the clinical target volume (CTV) and hence more dose to the organs at risk (OAR). It also effects in the conservative use of beam directions, which are often sub-optimal, to avoid irradiating normal tissues.
Dual energy CT (DE-CT) improves the accuracy of the SPR and therefore the proton range estimation.
An evaluation of the proton range for several tissues using SE-CT and DE-CT as input to Monte Carlo (MC) simulations showed on average improvements in range prediction from 0.1% to 2.1% when using DECT instead of SECT, but in several phantoms and also versus proton-CT, the errors on SE-CT based proton stopping power ratios are reported to be more than 7 %.
A limitation of these studies is that most of them were performed in phantoms. In the first clinical data set on five patients with base of skull tumours, it was reported that although the SPR estimation was indeed better for DE-CT than for SE-CT, its clinical relevance was unclear. However, in the same study, phantom measurements showed a large uncertainty of the SPR in the lung. This is due to the large heterogeneity of the lungs and the huge difference in the density of the lungs compared to the mediastinum, the tumour and the chest cavity.
It is therefore important to study the SPR differences of SE-CT compared to DE-CT in lung cancer patients and the impact on the dose distribution especially in the context of adaptive radiotherapy. As during the course of concurrent chemotherapy and radiotherapy, which is the standard treatment in the majority of stage III lung cancer patients, important anatomical changes may occur, it is also of clinical relevance to determine the influence of repeated dose calculations on DE-CT.
Studietyp
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
Limburg
-
Maastricht, Limburg, Nederländerna, 6229 ET
- Maastro Clinic
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Beskrivning
Inclusion Criteria:
- Histologically or cytologically confirmed locally advanced stage IIIA or III B (T0-4 N2-3M0) NSCLC, or M1 oligometastatic disease according to 7th TNM classification.
- Scheduled to receive concurrent chemotherapy and radiotherapy to a dose of at least 60 Gy, as decided at the multidisciplinary tumour board
- Able to give written informed consent
- Able to have adequate contraception in woman with child bearing potential
Exclusion Criteria:
- Not able to give written informed consent
- Not able to comply with adequate contraception in woman with child bearing potential
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Övrig
- Tilldelning: N/A
- Interventionsmodell: Enskild gruppuppgift
- Maskning: Ingen (Open Label)
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Experimentell: Scans
Patients included in the trial will receive DE-CT in stead of SE-CT's.
|
Patients included in the trial will receive 3 extra DE-CT's and 3 extra SE-CT's
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Dose distribution on the CTV (measured in Gy)
Tidsram: Measured during 2nd and 4th week of radiation treatment
|
Dose distribution on the CTV (clinical target volume) of the tumour and the lymph nodes of DE-CT vs. SE-CT
|
Measured during 2nd and 4th week of radiation treatment
|
|
Dose distribution on the OAR (measured in Gy)
Tidsram: Measured during 2nd and 4th week of radiation treatment
|
Dose distribution on the OAR (organs at risk), lungs, heart, aorta, pulmonary artery, superior vena cava, oesophagus, spinal cord, vertebral body, of DE-CT vs. SE-CT
|
Measured during 2nd and 4th week of radiation treatment
|
Samarbetspartners och utredare
Sponsor
Utredare
- Huvudutredare: Dirk De Ruysscher, MD, PhD, Maastro Clinic, The Netherlands
Studieavstämningsdatum
Studera stora datum
Studiestart
Primärt slutförande (Förväntat)
Avslutad studie (Förväntat)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Uppskatta)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- DE-CT
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .