DE-CT in Lung Cancer Proton Therapy (DE-CT)
DE-CT vs. SE-CT as Optimal Imaging During Treatment for Adaptive Proton Therapy in Stage III Non Small Cell Lung Cancer (NSCLC)
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Részletes leírás
In order to calculate the dose distribution of protons adequately, accurate estimations of the stopping power ratio (SPR) medium to water, are required. Using a conversion from single energy CT (SE-CT) images results in an uncertainty in the SPR of at least 3-4%. This uncertainty results in in the use of larger margins around the clinical target volume (CTV) and hence more dose to the organs at risk (OAR). It also effects in the conservative use of beam directions, which are often sub-optimal, to avoid irradiating normal tissues.
Dual energy CT (DE-CT) improves the accuracy of the SPR and therefore the proton range estimation.
An evaluation of the proton range for several tissues using SE-CT and DE-CT as input to Monte Carlo (MC) simulations showed on average improvements in range prediction from 0.1% to 2.1% when using DECT instead of SECT, but in several phantoms and also versus proton-CT, the errors on SE-CT based proton stopping power ratios are reported to be more than 7 %.
A limitation of these studies is that most of them were performed in phantoms. In the first clinical data set on five patients with base of skull tumours, it was reported that although the SPR estimation was indeed better for DE-CT than for SE-CT, its clinical relevance was unclear. However, in the same study, phantom measurements showed a large uncertainty of the SPR in the lung. This is due to the large heterogeneity of the lungs and the huge difference in the density of the lungs compared to the mediastinum, the tumour and the chest cavity.
It is therefore important to study the SPR differences of SE-CT compared to DE-CT in lung cancer patients and the impact on the dose distribution especially in the context of adaptive radiotherapy. As during the course of concurrent chemotherapy and radiotherapy, which is the standard treatment in the majority of stage III lung cancer patients, important anatomical changes may occur, it is also of clinical relevance to determine the influence of repeated dose calculations on DE-CT.
Tanulmány típusa
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi helyek
-
-
Limburg
-
Maastricht, Limburg, Hollandia, 6229 ET
- Maastro Clinic
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria:
- Histologically or cytologically confirmed locally advanced stage IIIA or III B (T0-4 N2-3M0) NSCLC, or M1 oligometastatic disease according to 7th TNM classification.
- Scheduled to receive concurrent chemotherapy and radiotherapy to a dose of at least 60 Gy, as decided at the multidisciplinary tumour board
- Able to give written informed consent
- Able to have adequate contraception in woman with child bearing potential
Exclusion Criteria:
- Not able to give written informed consent
- Not able to comply with adequate contraception in woman with child bearing potential
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Egyéb
- Kiosztás: N/A
- Beavatkozó modell: Egyetlen csoportos hozzárendelés
- Maszkolás: Nincs (Open Label)
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Kísérleti: Scans
Patients included in the trial will receive DE-CT in stead of SE-CT's.
|
Patients included in the trial will receive 3 extra DE-CT's and 3 extra SE-CT's
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Dose distribution on the CTV (measured in Gy)
Időkeret: Measured during 2nd and 4th week of radiation treatment
|
Dose distribution on the CTV (clinical target volume) of the tumour and the lymph nodes of DE-CT vs. SE-CT
|
Measured during 2nd and 4th week of radiation treatment
|
|
Dose distribution on the OAR (measured in Gy)
Időkeret: Measured during 2nd and 4th week of radiation treatment
|
Dose distribution on the OAR (organs at risk), lungs, heart, aorta, pulmonary artery, superior vena cava, oesophagus, spinal cord, vertebral body, of DE-CT vs. SE-CT
|
Measured during 2nd and 4th week of radiation treatment
|
Együttműködők és nyomozók
Szponzor
Nyomozók
- Kutatásvezető: Dirk De Ruysscher, MD, PhD, Maastro Clinic, The Netherlands
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete
Elsődleges befejezés (Várható)
A tanulmány befejezése (Várható)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Becslés)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- DE-CT
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .