DE-CT in Lung Cancer Proton Therapy (DE-CT)
DE-CT vs. SE-CT as Optimal Imaging During Treatment for Adaptive Proton Therapy in Stage III Non Small Cell Lung Cancer (NSCLC)
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
In order to calculate the dose distribution of protons adequately, accurate estimations of the stopping power ratio (SPR) medium to water, are required. Using a conversion from single energy CT (SE-CT) images results in an uncertainty in the SPR of at least 3-4%. This uncertainty results in in the use of larger margins around the clinical target volume (CTV) and hence more dose to the organs at risk (OAR). It also effects in the conservative use of beam directions, which are often sub-optimal, to avoid irradiating normal tissues.
Dual energy CT (DE-CT) improves the accuracy of the SPR and therefore the proton range estimation.
An evaluation of the proton range for several tissues using SE-CT and DE-CT as input to Monte Carlo (MC) simulations showed on average improvements in range prediction from 0.1% to 2.1% when using DECT instead of SECT, but in several phantoms and also versus proton-CT, the errors on SE-CT based proton stopping power ratios are reported to be more than 7 %.
A limitation of these studies is that most of them were performed in phantoms. In the first clinical data set on five patients with base of skull tumours, it was reported that although the SPR estimation was indeed better for DE-CT than for SE-CT, its clinical relevance was unclear. However, in the same study, phantom measurements showed a large uncertainty of the SPR in the lung. This is due to the large heterogeneity of the lungs and the huge difference in the density of the lungs compared to the mediastinum, the tumour and the chest cavity.
It is therefore important to study the SPR differences of SE-CT compared to DE-CT in lung cancer patients and the impact on the dose distribution especially in the context of adaptive radiotherapy. As during the course of concurrent chemotherapy and radiotherapy, which is the standard treatment in the majority of stage III lung cancer patients, important anatomical changes may occur, it is also of clinical relevance to determine the influence of repeated dose calculations on DE-CT.
Studietype
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
Limburg
-
Maastricht, Limburg, Nederland, 6229 ET
- Maastro Clinic
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Histologically or cytologically confirmed locally advanced stage IIIA or III B (T0-4 N2-3M0) NSCLC, or M1 oligometastatic disease according to 7th TNM classification.
- Scheduled to receive concurrent chemotherapy and radiotherapy to a dose of at least 60 Gy, as decided at the multidisciplinary tumour board
- Able to give written informed consent
- Able to have adequate contraception in woman with child bearing potential
Exclusion Criteria:
- Not able to give written informed consent
- Not able to comply with adequate contraception in woman with child bearing potential
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Ander
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Scans
Patients included in the trial will receive DE-CT in stead of SE-CT's.
|
Patients included in the trial will receive 3 extra DE-CT's and 3 extra SE-CT's
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Dose distribution on the CTV (measured in Gy)
Tijdsspanne: Measured during 2nd and 4th week of radiation treatment
|
Dose distribution on the CTV (clinical target volume) of the tumour and the lymph nodes of DE-CT vs. SE-CT
|
Measured during 2nd and 4th week of radiation treatment
|
|
Dose distribution on the OAR (measured in Gy)
Tijdsspanne: Measured during 2nd and 4th week of radiation treatment
|
Dose distribution on the OAR (organs at risk), lungs, heart, aorta, pulmonary artery, superior vena cava, oesophagus, spinal cord, vertebral body, of DE-CT vs. SE-CT
|
Measured during 2nd and 4th week of radiation treatment
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Dirk De Ruysscher, MD, PhD, Maastro Clinic, The Netherlands
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Verwacht)
Studie voltooiing (Verwacht)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- DE-CT
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .