- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT02844140
DE-CT in Lung Cancer Proton Therapy (DE-CT)
DE-CT vs. SE-CT as Optimal Imaging During Treatment for Adaptive Proton Therapy in Stage III Non Small Cell Lung Cancer (NSCLC)
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
In order to calculate the dose distribution of protons adequately, accurate estimations of the stopping power ratio (SPR) medium to water, are required. Using a conversion from single energy CT (SE-CT) images results in an uncertainty in the SPR of at least 3-4%. This uncertainty results in in the use of larger margins around the clinical target volume (CTV) and hence more dose to the organs at risk (OAR). It also effects in the conservative use of beam directions, which are often sub-optimal, to avoid irradiating normal tissues.
Dual energy CT (DE-CT) improves the accuracy of the SPR and therefore the proton range estimation.
An evaluation of the proton range for several tissues using SE-CT and DE-CT as input to Monte Carlo (MC) simulations showed on average improvements in range prediction from 0.1% to 2.1% when using DECT instead of SECT, but in several phantoms and also versus proton-CT, the errors on SE-CT based proton stopping power ratios are reported to be more than 7 %.
A limitation of these studies is that most of them were performed in phantoms. In the first clinical data set on five patients with base of skull tumours, it was reported that although the SPR estimation was indeed better for DE-CT than for SE-CT, its clinical relevance was unclear. However, in the same study, phantom measurements showed a large uncertainty of the SPR in the lung. This is due to the large heterogeneity of the lungs and the huge difference in the density of the lungs compared to the mediastinum, the tumour and the chest cavity.
It is therefore important to study the SPR differences of SE-CT compared to DE-CT in lung cancer patients and the impact on the dose distribution especially in the context of adaptive radiotherapy. As during the course of concurrent chemotherapy and radiotherapy, which is the standard treatment in the majority of stage III lung cancer patients, important anatomical changes may occur, it is also of clinical relevance to determine the influence of repeated dose calculations on DE-CT.
Tipo de estudo
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Limburg
-
Maastricht, Limburg, Holanda, 6229 ET
- Maastro Clinic
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Histologically or cytologically confirmed locally advanced stage IIIA or III B (T0-4 N2-3M0) NSCLC, or M1 oligometastatic disease according to 7th TNM classification.
- Scheduled to receive concurrent chemotherapy and radiotherapy to a dose of at least 60 Gy, as decided at the multidisciplinary tumour board
- Able to give written informed consent
- Able to have adequate contraception in woman with child bearing potential
Exclusion Criteria:
- Not able to give written informed consent
- Not able to comply with adequate contraception in woman with child bearing potential
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Outro
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Scans
Patients included in the trial will receive DE-CT in stead of SE-CT's.
|
Patients included in the trial will receive 3 extra DE-CT's and 3 extra SE-CT's
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Dose distribution on the CTV (measured in Gy)
Prazo: Measured during 2nd and 4th week of radiation treatment
|
Dose distribution on the CTV (clinical target volume) of the tumour and the lymph nodes of DE-CT vs. SE-CT
|
Measured during 2nd and 4th week of radiation treatment
|
|
Dose distribution on the OAR (measured in Gy)
Prazo: Measured during 2nd and 4th week of radiation treatment
|
Dose distribution on the OAR (organs at risk), lungs, heart, aorta, pulmonary artery, superior vena cava, oesophagus, spinal cord, vertebral body, of DE-CT vs. SE-CT
|
Measured during 2nd and 4th week of radiation treatment
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Dirk De Ruysscher, MD, PhD, Maastro Clinic, The Netherlands
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Antecipado)
Conclusão do estudo (Antecipado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- DE-CT
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .